IL-0348 Scaleway · 2025-03-10networking

Scaleway's FR-PAR region lost public internet connectivity when one 100 Gbps backbone link was saturated

On 10 March 2025 Scaleway's network team was connecting a new data center to its backbone in the FR-PAR region. A mistake in a router configuration made during that deployment sent more than 1 Tbps of traffic between OpCore DC3 and DC5 over a single 100 Gbps link at 16:23 UTC. The link saturated, most internet traffic was effectively blackholed, and public internet connectivity between FR-PAR-2 and the rest of the region was severely disrupted. The error was detected quickly and rolled back within four minutes; the correct configuration was in place and the network had converged by 16:27 UTC.

The network outage lasted five minutes, but rollback and switchover mechanisms in other products had activated against a zone that was entirely cut off, and their back and forth kept the network congested and many products unstable for longer. Object Storage, a regional product, stopped replicating between zones during the outage; a bug in its software let replication run without a rate limit afterwards, which saturated links and kept the service degraded until about 16:50 UTC. DNS recovered at 17:20 UTC, Instances at 17:10 UTC, and Object Storage and Kubernetes Kapsule at 18:00 UTC according to the product list.

Severity
–
Scope
Public internet connectivity for all products in FR-PAR, with DNS, Object Storage, Kubernetes Kapsule, Instances, Transactional Email, Dedibox servers in DC5 and Elastic Metal in FR-PAR-2 affected; VPC and Dedibox RPN were not affected
Users affected
–
Region
FR-PAR (fr-par-1, fr-par-2, fr-par-3 and DC5)
Time to detect
–
Time to resolve
1h 38m

Symptoms

On 10 March 2025 at 16:22 UTC, public internet connectivity in Scaleway's FR-PAR region broke for all products. Most internet traffic between the FR-PAR-2 availability zone and the rest of the PAR region was blackholed for about five minutes, while VPC traffic and Dedibox RPN kept working.

Products stayed broken for different lengths of time: authoritative and cache DNS from 16:23 to 17:20 UTC, Object Storage from 16:23 to 18:00 UTC, Kubernetes Kapsule from 16:23 to 18:00 UTC, virtual Instances from 16:23 to 17:10 UTC, and Transactional Email, Dedibox dedicated servers in DC5 and Elastic Metal in FR-PAR-2 from 16:23 to 16:27 UTC. A status page update posted at 18:19 CET said public connectivity in PAR2/DC5 was almost fully blackholed between 17:22 and 17:28.

Recovery took from minutes to tens of minutes after connectivity returned at 16:27 UTC. Rollback and switchover mechanisms in other products activated, but because the whole FR-PAR-2 zone was cut off they could not succeed, and their going back and forth heavily congested the network and made many products unstable. In Object Storage, replication between availability zones stopped during the outage and then ran without a rate limit once connectivity came back, saturating some links and causing latency and packet drops; the service was severely degraded across FR-PAR for about 25 minutes, until about 16:50 UTC. No customer data was lost.

Symptom Packet lossService outageHigh latency

Root cause

Trigger
While Scaleway's network team connected a new data center to the FR-PAR backbone, a human mistake in a router configuration rerouted more than 1 Tbps of traffic between OpCore DC3 and DC5 through a single 100 Gbps link.

Detection

The router configuration error was detected quickly and rolled back within four minutes.