IONOS Private Cloud in Berlin lost management access, storage and VM internet routing after a VLAN change

IONOS Cloud planned a maintenance on 15 January 2026 to introduce a new VLAN on the management devices in Berlin. The command that was run overwrote the existing VLANs on the trunk between the core and management devices instead of appending the new one, leaving only the new VLAN active. Access to several management interfaces was lost, the internal storage clusters that had interfaces on those management devices were disconnected, several VMs and Edge Nodes went read-only, and the NSX Edge Nodes lost external routing, cutting the VMs off from the internet. Restarting the affected services near the end of recovery caused a brief second outage. The status page reported the impact at 08:21 UTC, a fix and monitoring at 08:37 UTC and resolution at 09:25 UTC. IONOS planned an audit of the management device architecture for better segmentation and safeguards against unintended VLAN changes.

Severity
–
Scope
VMware-based Private Clouds: management VPN access, traffic to and from VMs, internal storage clusters, VMs and Edge Nodes in read-only mode, and external routing through NSX Edge Nodes
Users affected
–
Region
Berlin (Location DE/TXL)
Time to detect
–
Time to resolve
–

Symptoms

On 15 January 2026, network services for VMware-based Private Clouds in IONOS Cloud's Berlin location stopped working: customers lost management VPN access and traffic to and from their virtual machines. Inside IONOS, several management interfaces in the Berlin region could no longer be reached.

The loss spread from the management network to what depended on it. Internal storage clusters whose interfaces sat on the affected management devices were disconnected, and several VMs and Edge Nodes switched to read-only mode to protect their data. The NSX Edge Nodes, which connect the virtual networks to the physical network, lost external routing, so the VMs lost their internet connectivity. Late in the recovery, restarting the affected storage services caused a second, brief outage.

Symptom Network unreachableStorage disconnected or stale mounts

Root cause

Trigger
During a planned maintenance window to add a new VLAN to the management devices, a human error in the command replaced the existing VLANs on the trunk between the core and management devices instead of adding to them, so only the new VLAN stayed active.

Detection

–

Remediation

Action items

Lessons

–

Sources