IL-0349 IONOS Cloud · 2026-01-15networking
IONOS Private Cloud in Berlin lost management access, storage and VM internet routing after a VLAN change
IONOS Cloud planned a maintenance on 15 January 2026 to introduce a new VLAN on the management devices in Berlin. The command that was run overwrote the existing VLANs on the trunk between the core and management devices instead of appending the new one, leaving only the new VLAN active. Access to several management interfaces was lost, the internal storage clusters that had interfaces on those management devices were disconnected, several VMs and Edge Nodes went read-only, and the NSX Edge Nodes lost external routing, cutting the VMs off from the internet. Restarting the affected services near the end of recovery caused a brief second outage. The status page reported the impact at 08:21 UTC, a fix and monitoring at 08:37 UTC and resolution at 09:25 UTC. IONOS planned an audit of the management device architecture for better segmentation and safeguards against unintended VLAN changes.
- Severity
- –
- Scope
- VMware-based Private Clouds: management VPN access, traffic to and from VMs, internal storage clusters, VMs and Edge Nodes in read-only mode, and external routing through NSX Edge Nodes
- Users affected
- –
- Region
- Berlin (Location DE/TXL)
- Time to detect
- –
- Time to resolve
- –
Symptoms
On 15 January 2026, network services for VMware-based Private Clouds in IONOS Cloud's Berlin location stopped working: customers lost management VPN access and traffic to and from their virtual machines. Inside IONOS, several management interfaces in the Berlin region could no longer be reached.
The loss spread from the management network to what depended on it. Internal storage clusters whose interfaces sat on the affected management devices were disconnected, and several VMs and Edge Nodes switched to read-only mode to protect their data. The NSX Edge Nodes, which connect the virtual networks to the physical network, lost external routing, so the VMs lost their internet connectivity. Late in the recovery, restarting the affected storage services caused a second, brief outage.
Symptom Network unreachableStorage disconnected or stale mounts
Root cause
Root cause Operator error
- Trigger
- During a planned maintenance window to add a new VLAN to the management devices, a human error in the command replaced the existing VLANs on the trunk between the core and management devices instead of adding to them, so only the new VLAN stayed active.
Detection
–
Remediation
- Restarted the affected storage services in the final stage of recovery, which caused a brief second outage
Action items
- Audit the management device architecture to segment it better (target Q3 2026)
- Evaluate and implement ways to prevent unintended VLAN changes, such as improved configuration safeguards or automation scripts (target Q1 2026)
Lessons
–
Sources
- https://status.ionos.cloud/incidents/hgt9fqjj7vvm · official-status
Related cases
IL-0568A layer 2 loop after an access switch change broke network traffic across a whole DeNA site, with mass MACFLAP logsDeNA · 2026same root cause · shared Network switch
Check your cluster for this
For AI tools and scripts
- This case as JSON: https://incidentlib-api.benchlet.com/cases/IL-0349
- The cases most like it: https://incidentlib-api.benchlet.com/cases/IL-0349/similar
- MCP server (Streamable HTTP, no key):
https://incidentlib-mcp.benchlet.com/mcp
The API needs no key. The MCP server offers search_incidents, get_incident, list_incidents, get_topic and vocab; both are explained on API and MCP.