Cases8 cases
5 to 8 of 8
By root cause4
Software defect1 case
- Contributing factor
- Organisation
Capacity exhaustion2 cases
- Contributing factor
- Organisation
IL-0170During a Lunar New Year event, traffic more than three times normal filled the nf_conntrack table on the EKS node running the Istio ingress gateway, dropping packets and taking down Backpackr's web and app servicesBackpackr2025IL-0013The conntrack table filled up on downsized GKE nodes and a high-traffic aggregation proxy saw climbing connection resetsloveholidays2020
DNS or network fault4 cases
- Component
- Contributing factor
- Organisation
IL-0178On EKS, HPA scale-in returned 502 errors because containers stopped before their pod IPs left the Service endpoints, and after blue/green switches conntrack kept sending established connections to deleted pods behind an instance-mode ALBLotte E-commerce2022IL-0049Partial DNS outage after CoreDNS scaled down and kube-proxy failed to delete stale conntrack entriesPreply2020IL-0057Higher p99 latency after moving a reverse proxy to EKS, from outgoing connections delayed by a SNAT conntrack racePrezi2019IL-0047Pod-to-pod requests delayed by 5, 10 or 15 seconds because of DNS lookups lost to a conntrack raceMindTickle2019
Configuration change1 case
- Contributing factor
- Organisation