  1. Symptoms

    A Granite-20B training job running on 768 GPUs on IBM's Vela AI cluster suddenly showed a step time almost 3 times longer than before.

    Trigger

    A power card issue in one of the job's 96 nodes made the node throttle its GPUs from about 400W to roughly 150W.

    Root cause
    Component
    Contributing factor
    –
    Detection

    The team noticed the sudden rise in step time and debugged all 96 nodes of the job to find the node with the power card issue.

    Remediation
    • Debugged all 96 nodes of the job and found the node with the power card issue
    Action items
    • Add alerts at the infrastructure layer based on host VM logs, application logs and host BMC logs to find problem nodes quickly
    • Flag nodes with an active power break slowdown from nvidia-smi GPU counters in Autopilot and the Grafana dashboard
    Lessons

    In distributed training, a drop in the performance of a single node reduces the performance of the whole job until the slow node is identified and removed or fixed and the job restarts on healthy nodes. Alerts and health checks that locate such nodes let site reliability engineers tell users about infrastructure problems before the users notice them, and cut the time to find the root cause by over 2x.

  2. Symptoms

    On Google's TPU v4 supercomputers, a failed TPU machine, inter-chip interconnect (ICI) link or optical circuit switch (OCS) stopped the training jobs that used it, because a job's TPU processes all have to be up to update weights together over ICI collectives. Hardware outages hit about 1% of training jobs; jobs on a failed machine or ICI link were evicted, rescheduled onto healthy cubes and resumed from their latest checkpoint.

    Root cause
    Component
    Contributing factor
    –
    Detection

    healthd on each machine monitors ICI links, PCIe channels and TPU chips against modelled values and thresholds, a PCIe MSI-X interrupt reaches libtpunet when a link goes down, a TPU errors or the driver panics and libtpunet notifies Borg, a preflight check runs before every job, and the Pod Manager queries OCS health over RPC.

    Remediation
    • Marked the affected TPU machines unavailable and evicted running jobs with notice
    • Notified affected jobs so they could write an up-to-date checkpoint, and resumed rescheduled jobs from the latest checkpoint
    • Reconfigured jobs through the optical circuit switches to use spare healthy cubes after machine and ICI link outages
    • Routed traffic around links broken by an unavailable OCS with fault-tolerant wild-first routing
    • Drained broken ICI links and repaired them online while the TPUs stayed in use
    • Sent faulty hardware to a repair workflow and returned it to the pool after automated QA
    • Prioritised recovery time for OCS components over other components
    • Upgraded OCS parts across the fleet in a planned upgrade to improve reliability
    Action items
    • Add randomized routing to ICI switches for better load balancing in the presence of faults
    • Provision a hot-standby cube on an outage and migrate accelerator state to it without writing a persistent checkpoint
    Lessons

    In a static pod every resource in a contiguous block must be healthy at once, which becomes less likely as jobs grow, so job availability falls with size. Reconfiguring at the granularity of 16-machine cubes keeps the blast radius of a failure small while letting jobs use any healthy cubes, and fault-tolerant routing keeps cubes usable through rare OCS outages at a small cost in step time.

  3. Symptoms

    In the week of 10 October 2022, Linode Object Storage in Newark had two incidents of reduced performance and availability, on 10 and 16 October, and in some cases the front-end gateways returned 504 gateway timeouts to customers. The second incident began while the first was still being investigated.

    Trigger

    One back-end Object Storage node had a hardware problem that was not an outright failure, so the node kept going up and down.

    Root cause
    Component
    Contributing factor
    Remediation
    • Removed the failed back-end infrastructure from the Object Storage cluster
    Action items
    • Improve detection so subtle problems with failing or misbehaving hardware are found and triaged before they affect the wider cluster
    • Describe Ceph-related events more accurately to on-call administrators and define alerts more clearly
    Lessons

    Hardware that misbehaves without failing outright can cause service-wide problems, and Linode's internal monitoring had gaps in spotting such subtle issues before they affected the wider cluster.

  4. Symptoms

    The GLM-130B pretraining run on 96 nodes, started on 2022-05-06 at 04:00, was interrupted again and again by single nodes that broke down, lost connection or reported missing GPUs, and each time training had to be restarted from a saved step. On 2022-05-30 a restart got stuck in data loading because of a Lustre file system error, and the 2.3T text corpora could no longer be read.

    Trigger

    Individual nodes of the 96-node allocation failed during training, through breakdowns, a lost connection, missing GPUs, a CPU error and an NVLink error, and on 2022-05-30 the Lustre file system that held the training corpus failed.

    Root cause
    Component
    Contributing factor
    –
    Detection

    The Lustre error was found when a restart from global_step23200 stayed stuck in data loading.

    Remediation
    • Restarted the training from the last saved step after each node failure
    • Changed the checkpoint saving interval from 500 steps to 100 steps
    • Switched the job to another node pool and restarted from step 15600
    • Removed the suspected replacement node n30076 from step 16600, which did not change the speed
    • Copied the 2.3T text corpora from a backup disk back to the Lustre file system, which took a few days
Check your cluster for this

These 8 cases involve NIC, cable and switch port link and GPU hardware and memory. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause1