  1. Symptoms

    From 10:15 am PT on 25 November 2024 a large share of both API and ChatGPT traffic failed with timeouts and 503 errors.

    Trigger

    A global change to Kubernetes namespace labels caused the networking layer to recompute metadata. The change had rolled out to the small clusters without problems.

    Root cause
    Component
    Contributing factor
    Remediation
    • moved workloads out of the impacted clusters by hand
    • with the cloud provider, scaled up the number of control plane nodes while scaling down the number of data plane nodes, which let the control planes recover
    Action items
    • Lock namespace changes so this incident cannot recur
    • Freeze certain types of infrastructure deploys
    • Allowlist identities to prevent a recurrence of this class of incidents
    • Improve the GPU load balancing logic so traffic is re-routed automatically and more effectively when possible
    • Improve change management for fleet-wide infrastructure changes
  2. Symptoms

    From 17 October 2024, packets through the vSwitch that joined Namespace's bare metal machines at one provider in the fra3 region were dropped at random. Retries in TCP, QUIC and the Namespace control plane hid most of it, but the SLO error budget for latency targets on key interactions began to burn.

    Trigger

    Random packet drops on the bare metal provider's vSwitch from 17 October 2024; for the second outage, a rate of Kubernetes changes that the slow NVMe on one control plane node could no longer keep up with.

    Root cause
    Component
    Contributing factor
    Detection

    SLO-based monitoring of latency targets showed the error budget burning while retries hid the individual packet drops.

    Remediation
    • diverted all customer traffic from fra3 to other regions
    • connected each provider machine to the zrh1 cluster over Wireguard instead of the vSwitch
    • repaved every fra3 machine with a new identity, certificates and encryption-at-rest keys, dropping regional caches to recover faster
    • cloned existing datasets in a more distributed way to speed up repaving the machines
    • added machines back to the new region in batches and returned the region to the compute pool
    • redirected workloads away from zrh1 during the second outage
    • cloned the failing control plane node's key state to a higher-capacity node that took over its role and IP address
    Action items
    • Credit all instances that ran during the outages back to customers
    • Build up backup regions and solutions so a similar event has options that do not affect customers
    Lessons

    Running hot with a delayed hardware delivery left no room to take a region out, so fixing a provider network fault turned into a global capacity shortage. After one outage the team was anchored on its cause and first looked for network problems in the second outage, which had a different cause: a control plane node whose disk could not keep up with the Kubernetes change rate.

  3. Symptoms

    From 22:25 to 22:50 UTC every DigitalOcean service in the SFO3 region had network connectivity problems, as traffic between the datacenter and the backbone dropped. Traffic through the router was back by 22:30 and SFO3's control plane systems had reconnected by 22:50, and most services recovered then.

    Trigger

    Most of the line cards on one SFO3 core router rebooted at the same time at 22:21 UTC because of hardware errors on the device.

    Root cause
    Component
    Contributing factor
    –
    Remediation
    • The crashed line cards came back online and traffic on the core router was restored
    • Manually recycled all affected nodes across the SFO3 DOKS fleet
    Action items
    • Work with the router vendor's support team to find the root cause of the line card crash
    • Upgrade software on the core routers in SFO3
    • Raise thresholds for automated remediation so affected nodes are restored without manual action
    Lessons

    A short network fault can leave Kubernetes nodes broken long after the network itself is healthy, when the guest networking on the machines does not recover by itself. Checking node health and the API servers after the network returns, and having automated remediation that is allowed to replace many nodes at once, shortens that tail.

  4. Symptoms

    A production EKS cluster on Kubernetes 1.30 went into read-only mode: the API server rejected every request that would change an object, such as creating pods or scaling deployments, and deleting objects to free space did not work either.

    Trigger

    Kyverno 1.12 kept creating ephemeralreports objects that piled up in etcd until the database passed EKS's size limit.

    Root cause
    Component
    Contributing factor
    Detection

    The cluster rejected writes; the audit logs carried the "etcdserver: mvcc: database space exceeded" error.

    Remediation
    • AWS raised the etcd storage limit from 8/10GB to 12GB to unlock writes
    • an AWS engineer deleted the leaked Kyverno ephemeralreports objects directly from etcd
    Action items
    • Monitor the etcd database size with apiserver_storage_size_bytes and never let it reach 8GB
    • Upgrade Kyverno 1.12 to 1.12.4, which fixes the ephemeralreports pile-up, or disable reporting for admission events and tune --aggregationWorkers
    Lessons

    On EKS, once etcd hits its size limit the cluster becomes read-only and only AWS can clean it up, so cleanup scripts must run before the limit is reached. Watch the etcd database size and object counts per resource, especially for controllers that create report objects.

  5. Symptoms

    At 01:04 CET on 13 February 2024, the Kubernetes API behind Scaleway's managed Kubernetes services Kapsule and Kosmos in the Paris region (FR-PAR) spiked in RAM and CPU use and ran out of memory. Nodes in FR-PAR could no longer authenticate to their control plane, and some of them went "Not Ready". Customers on both shared (mutualized) and dedicated environments were affected.

    Trigger

    A new Kubernetes release was made available to all users on 12 February 2024, and during the night of 12 to 13 February many clusters triggered their auto-upgrade at the same time.

    Root cause
    Component
    Contributing factor
    Detection

    The timeline's first entry, at 01:04 CET, records the Kubernetes API's RAM and CPU spikes and out-of-memory state, with nodes unable to authenticate to their control plane and some becoming "Not Ready". The first recorded action, 42 minutes later at 01:46, was to increase the resources allocated to the API.

    Remediation
    • increased the resources allocated to the Kubernetes API at 01:46 and again at 02:20
    • applied API traffic restrictions at 02:30 to smooth the incoming traffic
    • removed the traffic restrictions progressively in 50-100 batches from 03:20
    • ran a script at 03:40 to replace the failing nodes created during the congestion
    • rolled back to the former node authentication mechanism, first on a subset of clusters from 15:45 and on all clusters by 19:41 on 19 February
    • disabled cluster upgrade and configuration update features until 10:30 on 20 February
    Action items
    • Increase the resources allocated to the Kubernetes API
    • Roll back to the former node authentication mechanism
    • Implement a local authentication cache on nodes
    • Rework the resource allocation strategy to behave better under load spikes
    • Add new request queuing mechanisms for Kubernetes
    • Separate the different components to reduce side effects under high load or failure
    • Monitor selected metrics closely to identify anomalous patterns earlier
    • Refund customers who deployed nodes during the incident but could not use them normally
    Lessons

    Letting many clusters auto-upgrade at the same moment after a release turns routine upgrades into one coordinated load spike on the shared Kubernetes API. A node authentication mechanism that retries without letting up turns a slow API into an unavailable one, and auto-healing that replaces NotReady nodes amplifies the problem. The congestion pattern had already appeared three weeks earlier, and short-term mitigations did not stop it from recurring, so Scaleway rolled back the new authentication mechanism. Scaleway notes that as the number of customer clusters and nodes grows sharply, traffic control mechanisms have to improve to prevent congestion.

Check your cluster for this

These 28 cases involve Kubernetes API server and etcd. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause9

Credential exposure1 case

Contributing factor
  1. IL-0069 Attackers stole a high-privilege service account token from a production Kubernetes cluster and used it to reach a cryptocurrency exchange's financial systems

Certificate or credential expiry3 cases

  1. IL-0183 kubeadm's one-year leaf certificates expired, so kube-apiserver could not reach etcd, restarted in a loop and left the cluster unreachable
  2. IL-0113 The managed GKE control plane of Webhook Relay's main cluster failed because its API server certificates had never been rotated, and a manual credential rotation reported success without taking effect
  3. IL-0184 JupyterHub's KubeSpawner could not create containers and kubectl was refused because the API server and other internal certificates of a kubeadm cluster had expired
    dbhang2021

Software defect5 cases

  1. IL-0138 A failed Nvidia driver build left broken kernel packages on the only Kubernetes master node, which hit a kernel panic on reboot after a power outage and took the homelab cluster down for six days
  2. IL-0077 EKS cluster went read-only for over seven hours after Kyverno ephemeralreports filled the etcd database past its size limit
  3. IL-0030 Most nodes of a cluster went NotReady together for 15 minutes while the API server sat behind an AWS ELB
  4. IL-0072 High etcd write latency made the API servers return stale data, and the production cluster flipped between two views of its state
  5. IL-0003 linkerd lost Kubernetes service discovery after an etcd reconfiguration, and restarting every linkerd instance turned failed payments into a full platform outage
    Monzo2017

Capacity exhaustion9 cases

  1. IL-0204 An etcd memory spike overloaded the control plane of a Render Frankfurt cluster, and DNS then failed because CoreDNS ran on the rebooted control plane nodes and could not start without the API server
    Render2024
  2. IL-0168 Simultaneous cluster auto-upgrades overloaded Scaleway's Kubernetes API, and a node authentication retry loop kept Kapsule and Kosmos nodes NotReady in FR-PAR
  3. IL-0195 The kube-apiservers of a cluster with more than 200 nodes ran out of memory and crashed one after another under mass LIST requests from Cilium agents
    Palark2023
  4. IL-0165 Some LKE users in Frankfurt could not reach their kube-apiservers with kubectl after backend services failed under memory constraints
    Linode2023
  5. IL-0194 After a kube-apiserver restart, pod LIST requests from every pod of a Vector DaemonSet nearly tripled etcd memory and restarted all master nodes
    Palark2023
  6. IL-0002 CI builder pods could not get AWS IAM credentials because kubelet fell minutes behind its API rate limit
  7. IL-0076 Kubernetes masters went down after Dex filled etcd with AuthRequest objects and deleting its namespace started an endless list-and-timeout loop
  8. IL-0075 Kubernetes API servers pegged on CPU when the cluster grew to about 290 nodes, traced to Datadog agents polling the API
  9. IL-0031 Kubernetes API server OOM-killed, leaving the Skipper ingress without routes; the talk points to a misconfigured CronJob manifest

Configuration change6 cases

  1. IL-0005 A new telemetry service overloaded the Kubernetes API servers of large clusters and broke DNS-based service discovery for all OpenAI services
    OpenAI2024
  2. IL-0118 A global change to Kubernetes namespace labels made the networking layer recompute metadata and overwhelmed the control planes of three of OpenAI's largest GPU clusters
    OpenAI2024
  3. IL-0152 An incorrect configuration applied during maintenance made an internal infrastructure cluster automatically delete the control planes of 200 DOKS clusters in FRA1
  4. IL-0068 Anonymous access to the Kubernetes API server used to plant a ClusterRoleBinding backdoor and a cryptominer DaemonSet
  5. IL-0108 An Alcide admission controller applied to the production cluster during a workshop made create and update requests on Deployments time out
    DFDS2020
  6. IL-0008 An unresponsive OPA validating webhook crash-looped the API server during a GKE master upgrade, and node auto-repair then recreated every node

Cloud provider outage1 case

Organisation
  1. IL-0084 Packet drops on a bare metal provider's vSwitch forced Namespace to rebuild its fra3 region and left global capacity short, and the next day slow NVMe writes on a control plane node drove the Kubernetes API server to very high CPU

DNS or network fault1 case

Contributing factor
–
Organisation
  1. IL-0154 Line cards on an SFO3 core router rebooted together and halved backbone capacity, and DOKS nodes whose guest networking did not recover stayed NotReady with degraded API servers until all affected nodes in the SFO3 DOKS fleet were recycled

Breaking change in an upgrade1 case

Organisation
  1. IL-0060 Kubernetes 1.24 upgrade removed the master node label that Calico route reflectors selected on, dropping all pod routes and taking Reddit down for 314 minutes
    Reddit2023

unknown1 case

Organisation
  1. IL-0059 Single-master Kubernetes control plane kept dying because the kubelet restarted a healthy etcd on a failing kubeadm liveness probe