  1. Symptoms

    Prometheus alerts fired on tail latency: from 7/24, the p99 response time of a few services went up after Prezi moved its Nginx-based reverse proxy, smartgateway, from dedicated Elastic Beanstalk machines onto shared Kubernetes worker nodes. The bump affected only the tail, so the earlier monitoring of average response times would most certainly have missed it.

    Trigger

    Moving the reverse proxy onto shared EKS worker nodes, where its outgoing connections went through source NAT on the node and some SYN packets were dropped by a race in Netfilter's conntrack.

    Root cause
    Component
    Contributing factor
    Detection

    Prometheus alerts on p99 latency fired after the reverse proxy migration.

    Remediation
    • added AWS X-Ray tracing and an $upstream_connect_time trace attribute to locate the delay
    • ran more pods of the service on more nodes, which reduced but did not end the delays
    • set AWS_VPC_K8S_CNI_EXTERNALSNAT=true on the AWS VPC CNI to turn off SNAT on the nodes
    Lessons

    Alerting on tail latency instead of averages caught a problem that would otherwise have gone unnoticed, and tracing turned a vague slowdown into a measured connect delay. Delays of exactly 1 or 3 seconds on new outgoing connections point to dropped SYN packets, and on EKS the SNAT done by the VPC CNI is where to look.

  2. Symptoms

    Pod-to-pod calls were intermittently slow and the web application felt slow overall. A request that pod A sent at time x reached pod B at x + 5s, x + 10s or x + 15s, always a multiple of five seconds.

    Trigger

    The C library resolver sent the A and AAAA queries for each lookup on the same port; where DNAT or SNAT translation takes place, a race condition in conntrack sometimes left one of the queries unanswered, and the resolver waited 5 seconds before retrying.

    Root cause
    Component
    Contributing factor
    Detection

    The team noticed intermittent delays in pod-to-pod calls and slowness in the web application, and that the delays were always multiples of five seconds.

    Remediation
    • added the single-request-reopen option to dnsConfig in the deployment specs
    • set GRPC_DNS_RESOLVER=native in the Dockerfiles of gRPC applications so they used the libc resolver
    • checked with tcpdump port 53 that A and AAAA queries left from different ports
    Lessons

    Delays that are exact multiples of five seconds point to DNS lookups being retried after the resolver's 5-second timeout. A resolver option set in the pod spec only helps processes that use the libc resolver; runtimes with their own resolver, such as gRPC with c-ares, ignore it.

  3. Symptoms

    On Friday, January 18, Moonlight's API began returning occasional errors that looked like connection problems with its Redis database. The API checks Redis on every authenticated request to validate the session. At the same time the Kubernetes monitoring reported some nodes and pods as unresponsive.

    Trigger

    The Kubernetes scheduler put several CPU-heavy pods on the same node, including all three replicas of the website and the server-side rendering pods.

    Root cause
    Component
    Contributing factor
    Detection

    API errors that looked like Redis connectivity problems, and Kubernetes monitoring that showed nodes and pods as unresponsive. Google Cloud Support later found the link between sustained 100% CPU and kernel panics.

    Remediation
    • added anti-affinity rules to all major deployments so their pods spread across nodes
    Action items
    • Keep working with Google Cloud support to find and fix the cause of the node kernel panics
    Lessons

    Three replicas give no fault tolerance if the scheduler places them all on one node; anti-affinity rules make the spread explicit. A node failure that comes from the workload itself moves with the workload when the scheduler reschedules it.

Check your cluster for this

These 12 cases involve Linux kernel and Node operating system image. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause5

Breaking change in an upgrade2 cases

Organisation
  1. IL-0079 A GKE node auto-upgrade to an ubuntu_containerd image with a kernel regression left kube-proxy unable to apply its ip6tables rules, so load balancer health checks failed and several clusters lost all ingress traffic
  2. IL-0201 A framework upgrade caused kernel panics in GitHub's Kubernetes infrastructure, and GitHub.com web and API requests, mostly for issues and pull requests, failed intermittently for about 16 hours
    GitHub2025

Software defect5 cases

  1. IL-0138 A failed Nvidia driver build left broken kernel packages on the only Kubernetes master node, which hit a kernel panic on reboot after a power outage and took the homelab cluster down for six days
  2. IL-0112 The daily node rollover put DFDS's EKS nodes on an AMI later recalled for a kernel issue, causing "PLEG is not healthy" NodeNotReady flaps and pod network timeouts
    DFDS2022
  3. IL-0029 Slow user-facing services from CPU throttling on containers that used far less CPU than their limit
    Buffer2020
  4. IL-0012 CPU limits and an unpatched kernel CFS quota bug throttled multi-threaded services into stalls, failed health checks and timeouts
    Omio2020
  5. IL-0143 GKE nodes upgraded to certain 1.13 and 1.14 versions had an elevated number of kernel panics, fixed by releases that downgraded the Container-Optimized OS image

Configuration change1 case

Organisation
  1. IL-0153 DOKS worker nodes went NotReady at 06:00 UTC on three days because a systemd timer in the Debian image ran apt upgrade and killed it mid kernel upgrade, breaking node networking

Capacity exhaustion2 cases

Organisation
  1. IL-0176 Prometheus in a 235-node Kubernetes cluster crash-looped because over two million series exhausted host memory and the kernel OOM killer chose it first, as Burstable QoS gave it oom_score_adj 999
    LINE2020
  2. IL-0064 CPU-heavy pods packed onto one Google Cloud node drove it to kernel panics, and the crash moved from node to node until the site was down

DNS or network fault2 cases

Organisation
  1. IL-0057 Higher p99 latency after moving a reverse proxy to EKS, from outgoing connections delayed by a SNAT conntrack race
    Prezi2019
  2. IL-0047 Pod-to-pod requests delayed by 5, 10 or 15 seconds because of DNS lookups lost to a conntrack race