  1. Symptoms

    When Imbue brought up a cluster of 4,088 H100 GPUs on 511 hosts, about 10% of the machines failed to boot, mostly from physical problems: unconnected or miswired Ethernet cables, iDRAC hardware issues, broken power supplies, bad NVMe drives, missing internal wires, and network cards or GPUs that did not show up. In single-node GPU tests, Ubuntu server logs showed links between the GPUs and the PCIe buses or network cards reporting "limited width: x4 < x16". A few hosts had NVMe drives that locked up the whole machine when touched, drives that appeared in random order and got the OS installed on the wrong one, wrong temperature readings that kept fans at 100%, and CPUs limited to 2 GHz.

    Trigger

    Bringing a new InfiniBand-connected H100 cluster into service and running the first multi-node training jobs on it.

    Root cause
    Component
    Contributing factor
    Detection

    Automated hardware checks during provisioning, UFM alerts on temperature, error rates and flapping ports, Prometheus node exporter and DCGM metrics, per-batch MFU monitoring, and live debugging of stalled processes with Py-Spy, GDB and NVIDIA Nsight.

    Remediation
    • Automated checks for broken machines and sent faulty ones back to Dell or to data center staff
    • Reseated GPUs and internal PCIe cables and applied firmware upgrades
    • Downgraded the NVIDIA driver that caused wrong temperature readings
    • Rewired the top tier of the InfiniBand fabric into a single network and added checks that the wiring matched the design
    • Cleaned and reseated alerting ports and disabled the remaining alerting transceivers
    • Ran a burn-in workload through every InfiniBand port and disabled the ports that did not survive it
    • Enabled GPUDirect RDMA with an extra kernel module and PCIe ACS disabled
    • Disabled automatic garbage collection and scheduled it at set intervals on all hosts
    Action items
    • Release host-level health checks that confirm a host is free from known errors
    • Release an NCCL patch that improves logging around errors and stalls
    • Release a GPU stress test and NVLink and InfiniBand networking tests
    • Release a script that parses the UFM event log and decides which network ports to disable
    • Release a script that generates a burn-in workload exercising every InfiniBand link
    • Relaunch crashed runs automatically from the last checkpoint on the machines that pass health checks
    • Replace the disabled alerting transceivers
    Lessons

    Keep 10 to 20% more machines than a run needs, and network them so any working subset can be used. On the newest hardware expect about 3% of machines to break each week, mostly the same few machines breaking in different ways, so growing a set of known reliable "golden" hosts works better than chasing random failures. Write tests and automation for every kind of failure met, because each one comes back, and write tools that make opaque errors readable. Change only one thing at a time, and double-check the claims of new tools and people before building on them.

  2. Symptoms

    On a Friday afternoon a tenant of SCHIP, Adevinta's multi-tenant Kubernetes runtime, reported a spike of HTTP 5xx errors in some of its services. The drops in quality of service came back periodically through the following days, each one short, and were reported mostly around midnight.

    Root cause
    Component
    Contributing factor
    Detection

    A tenant reported a spike of HTTP 5xx errors in some of its services; the DNS Latency SLI had already been degraded for some time without being acted on.

    Remediation
    • raised the dnsmasq concurrent query limit from 150 to 1500
    • added a CoreDNS header block that sets the ra and aa flags and clears rd, so dnsmasq caches cluster.local answers
    • configured dnsmasq on each node to answer NXDOMAIN for unresolvable search-domain names instead of forwarding them to CoreDNS
    • changed the fluent-bit log router hostname to a fully qualified name
    • asked the affected tenants to use fully qualified names for internal calls
    Lessons

    The DNS Latency SLI had shown the problem long before anyone looked at it. An SLO only protects you when its SLIs are trusted and a drop is investigated. The investigation took a month partly because several on-call groups worked on it separately, without one place for observations and hypotheses, and sometimes chased hypotheses already discarded. Disprove one hypothesis before starting the next, and collect data the metrics system lacks: DNStop showed the garbage lookups that no dashboard did. With ndots:5, short service names multiply DNS traffic; a node-local cache only helps if it can cache the cluster DNS answers at all.

  3. Symptoms

    At around 2 AM ICT on 2023-04-09 the team saw unusual CPU use on one cluster node, which throttled every other service on it and made them fail. They presumed an upstream container runtime bug in containerd and runc and decided to fully reboot the affected nodes, taking the cluster down for maintenance on the assumption that it was not in active use.

    Trigger

    A full cold reboot of the nodes that showed unusual CPU use, followed by upgrades and cold reboots of the other nodes.

    Root cause
    Component
    Contributing factor
    Detection

    The team saw unusual CPU use on a node around 2 AM ICT and failing services on the rebooted nodes around 2:30 ICT; developers reported the Terra repositories down at 6:31 ICT.

    Remediation
    • uninstalled Multus and Calico and replaced them with the Cilium CNI
    • rolled back most cluster settings except the CNI
    Lessons

    Rebooting nodes to clear one problem can expose another; here a CNI chain could not reach the API server after a cold start. Repeating the same reboot on more nodes while the first failure was not understood spread the outage from a few nodes to the whole cluster. The team also found that Cilium's real resource use in their cluster was acceptable, contrary to the benchmark they had relied on.

  4. Symptoms

    The graph of WebSocket connections to messaging-hub, the messaging platform used by the Japanese food delivery service Demaecan, showed sudden deep drops even outside peak traffic. The drops kept coming back at irregular intervals. Messages still reached clients, because messaging-hub switches to Firebase Cloud Messaging when a WebSocket is gone.

    Trigger

    Another service that shared the same L7 load balancer deployed its own load balancer configuration in the Verda dashboard, which reloaded HAProxy; 30 minutes later, at the hard-stop-after limit, the old HAProxy process exited and closed every WebSocket connection it still held.

    Root cause
    Component
    Contributing factor
    Detection

    The developer noticed deep, sudden drops in the WebSocket connection graph that were not tied to peak traffic and kept recurring irregularly. The Nginx packet drops were found through network monitoring.

    Remediation
    • separated the Merchant system's token issuance API into its own deployment so reconnect traffic did not delay other Merchant APIs
    • scaled out Nginx with pod anti-affinity and a label selector so each pod ran on a different node, which stopped the nf_conntrack packet drops
    • raised Ingress Nginx proxy-read-timeout and proxy-send-timeout and the load balancer timeout to 3600s, which did not stop the drops
    • moved messaging-hub from the shared L7 load balancer to an L4 load balancer, which ended the WebSocket drops
    Lessons

    A reload of a shared load balancer by a different team can cut long-lived connections, and with hard-stop-after the cut comes 30 minutes later, far from the change that caused it. The author's lesson is not to narrow the scope of the search too early: trusting that the infrastructure was fine kept the investigation inside the team's own systems for days. A reconnect wave from many WebSocket clients can overload the systems that issue connection tokens and fill nf_conntrack on proxy nodes. Scaling Nginx out only helps for conntrack if the pods land on different nodes, and anti-affinity leaves extra replicas Pending once they outnumber the nodes. That messaging-hub problems can still load the connected systems remains an open problem.

  5. Symptoms

    The web service breached its latency SLO at 07:30 UTC and its Apdex dropped: some requests to the GitLab.com web front end slowed down for about 15 minutes. This happened while web traffic was being shifted from virtual machines to the web pods on Kubernetes, and the pods did not scale up as the traffic arrived.

    Trigger

    Shifting web traffic from VMs to Kubernetes pods during the GitLab.com web migration.

    Root cause
    Component
    Contributing factor
    Detection

    The web latency SLO breach at 07:30 UTC; an engineer declared the incident in Slack at 07:40.

    Remediation
    • Lowered the target CPU utilisation of the web pods' autoscaler to a more conservative value (merge request gitlab-com/gl-infra/k8s-workloads/gitlab-com!1149)
    Action items
    • Adjust the target utilisation for the web pods (gitlab-com/gl-infra/k8s-workloads/gitlab-com!1149)
    Lessons

    When traffic is moved onto pods that rely on CPU-based autoscaling, a CPU target set too high can keep the pods from scaling as the traffic arrives; GitLab fixed it by setting a more conservative target.

Check your cluster for this

These 35 cases involve Telemetry agent and Application database. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause10

Configuration change9 cases

  1. IL-0179 With DEBUG logging and synchronous log output, a high-traffic service filled the 64 KB stdout pipe, so request threads blocked in write() while holding database connections and HikariCP ran dry, failing requests in 30-second bursts
  2. IL-0063 VPN outage after recreating a Redis StatefulSet restarted the whole Redis cluster without readiness checks
  3. IL-0192 A Crossplane composition merge-policy change for a TLS policy update switched Kubernetes Services from LoadBalancer to ClusterIP and deleted the load balancers behind about 25% of Grafana Cloud services
  4. IL-0177 WebSocket connections to LINE's messaging-hub on Kubernetes dropped all at once whenever another service's change reloaded a shared HAProxy L7 load balancer, and the reconnect wave overloaded a token API and filled nf_conntrack on Nginx
    LINE+2022
  5. IL-0209 A too-high HPA CPU target kept GitLab.com web pods from scaling up as traffic moved from VMs to Kubernetes, breaching the web latency SLO for 15 minutes
    GitLab2021
  6. IL-0105 Replacing the AWS VPC CNI during a Terraform refactoring detached the ALB target groups, and every service in the Kubernetes cluster returned 503
    DFDS2021
  7. IL-0108 An Alcide admission controller applied to the production cluster during a workshop made create and update requests on Deployments time out
    DFDS2020
  8. IL-0061 A Terraform pull request merged out of order deleted a production GKE cluster, and recreating it deleted a second one
  9. IL-0066 Broken ConfigMap change lay dormant for weeks, then took down Pusher's edge proxy when a cluster upgrade replaced its pods
    Pusher2019

Software defect8 cases

  1. IL-0058 Argo CD deleted namespaces shared by several applications, leaving about 97 applications stuck Missing and OutOfSync
  2. IL-0171 Karpenter node auto-repair replaced EKS GPU nodes about 10 minutes after they became Ready, in a loop, because the Bottlerocket NVIDIA AMI lacked libdcgm.so and set AcceleratedHardwareReady to False
    Inflab2025
  3. IL-0029 Slow user-facing services from CPU throttling on containers that used far less CPU than their limit
    Buffer2020
  4. IL-0196 Adding a second Redis replica and lowering memory limits in one RedisFailover change restarted the only Redis pod that held data, and Sentinel promoted the empty new replica, erasing the data
    Palark2020
  5. IL-0062 Intermittent 502 errors behind a GKE Ingress because pods shut down before the load balancer stopped sending them traffic
  6. IL-0011 HAProxy ingress piled requests onto the same pods because a Go template visited the backend map in sorted pod IP order
  7. IL-0050 Pods on Kubernetes failed to resolve an external Redis hostname because of ndots:5, the musl resolver in Alpine images, and Netty's DNS resolver
  8. IL-0051 A third-party log shipping client leaked file descriptors with every new container until nodes failed with too many open files

Breaking change in an upgrade1 case

Organisation
  1. IL-0097 A cluster autoscaler version bump was incompatible with the one cluster still on Kubernetes 1.33, so no scale-up events fired and new nodes were not created
    2i2c2026

Faulty deployment3 cases

  1. IL-0160 A repaired legacy GPU monitoring script sent a firmware query that triggers a race condition in the GPU System Processor of NVIDIA RTX 4000 Ada GPUs, locking up GPU Linodes and LKE worker nodes in several regions
    Linode2026
  2. IL-0188 Rolling updates on EKS returned 502 errors for about 30 seconds because Kubernetes deleted old pods as soon as new pods passed readiness, before the ALB had marked the new pod targets healthy
  3. IL-0034 A crashing stats agent sidecar marked every pod unready and the service mesh pulled all services out of traffic
    Airbnb2019

Capacity exhaustion6 cases

  1. IL-0129 Throughput of the 384-GPU SmolLM3 pretraining run collapsed because shared WekaFS storage evicted dataset shards to S3, then kept dropping on local NVMe because the nanotron dataloader built an index that grew with the step count
  2. IL-0006 VPC subnets ran out of IP addresses because the AWS VPC CNI kept IPs on full nodes, and WARM_IP_TARGET changes then blocked pod starts after every pod deletion
    Neon2025
  3. IL-0094 Student pods filled the shared nodes of a JupyterHub cluster and starved the hub's core pods, freezing the hub
    2i2c2020
  4. IL-0064 CPU-heavy pods packed onto one Google Cloud node drove it to kernel panics, and the crash moved from node to node until the site was down
  5. IL-0075 Kubernetes API servers pegged on CPU when the cluster grew to about 290 nodes, traced to Datadog agents polling the API
  6. IL-0036 A reindex Job that kept failing exhausted one node after another until the whole cluster was down

Dependency failure1 case

Organisation
  1. IL-0025 Failed boots, InfiniBand link flapping, NCCL hangs and throughput sags while bringing up a 4,088-GPU H100 training cluster
    Imbue2024

DNS or network fault2 cases

  1. IL-0083 Intermittent 5xx errors in a multi-tenant Kubernetes cluster came from internal DNS: the node-local dnsmasq hit its 150 concurrent query limit, did not cache cluster.local answers, and ndots search lookups flooded CoreDNS
  2. IL-0056 Calls from EKS pods to services behind an NLB in another VPC failed intermittently because the AWS VPC CNI did source NAT on the node

unknown1 case

Organisation
  1. IL-0087 After a cold reboot of RKE2 nodes, pods could not get IP addresses because Multus could not reach the Kubernetes API, and further reboots spread the failure to every node

Operator error2 cases

Organisation
  1. IL-0197 Moving a three-node Elasticsearch StatefulSet to new persistent volumes split the cluster in two, because the Helm chart hardcoded cluster.initial_master_nodes to elasticsearch-0
    Palark2021
  2. IL-0054 All ingress traffic lost while draining a GKE node pool because the load balancer only targeted new nodes without ingress-nginx pods

Cloud provider outage2 cases

  1. IL-0172 An AWS Tokyo data centre cooling failure took down 6 of 60 CockroachDB nodes on Kubernetes within 22 minutes, and ranges lost quorum because the Helm-deployed cluster had no availability zone locality configured
  2. IL-0193 A GCP persistent disk degradation took down a Cassandra StatefulSet whose OrderedReady policy blocked recovery, and Metrictank could not reconnect to the recreated pods, causing a 23-hour Graphite query outage