Incident Library
Applied filters FactorChange with a delayed effectClear allEvery case under the filters, with no sentence; newest first.
Suggested filters Search, and the values found in your words appear here.

Graph

  • Root cause
  • Component
  • Symptom
  • Contributing factor
  • Case

Cases11 cases

1 to 5 of 11

  1. Symptoms

    An attempt to launch a new hub failed because its ingress could not obtain a new TLS certificate. The day before, the same engineer had recreated the support deployment on the 2i2c-aws-us cluster and seen its TLS certificate orders stuck pending.

    Trigger

    Creating new hub deployments that needed new TLS certificates on clusters recently migrated from ingress-nginx to nginx-ingress.

    Root cause
    Component
    Contributing factor
    Detection

    An attempt to launch a new hub failed; the engineer had seen certificate orders stuck pending on another cluster the day before and declared an incident.

    Remediation
    • annotated the Ingress objects that need TLS so that cert-manager could edit them in place to complete the ACME challenge
    Action items
    • Follow-up tracked in https://github.com/2i2c-org/infrastructure/issues/8016
    • Follow-up tracked in https://github.com/2i2c-org/infrastructure/issues/3278
    Lessons

    Swapping one ingress controller for another can change how Ingress objects that share a host are combined. cert-manager's temporary challenge Ingress depends on that behaviour, so the breakage shows up when a deployment needs a new certificate. 2i2c notes that it got lucky: it had already learned of this possible cause while testing on an internal cluster, and changing the cert-manager configuration was quick.

  2. Symptoms

    Between about 4:26 PM and 4:56 PM PST on 4 March 2026, some OpenAI API requests to several models failed or took longer than usual, and some Codex traffic was affected too. The overall API success rate dropped temporarily.

    Trigger

    A protective circuit breaker that had paused some scheduling operations was released, and the infrastructure actions queued during the pause were executed at the same time.

    Root cause
    Component
    Contributing factor
    Remediation
    • manually reassigned infrastructure resources to the affected models
    • brought the removed inference engines back online and reassigned them until error rates returned to normal
    Action items
    • Improve safeguards in the automated capacity management systems so they detect and respond to state drift
    • Improve observability of circuit breakers and scheduling systems so their status and effects are easier to identify
    • Add safeguards so queued actions cannot run in large batches after long pauses
    • Improve monitoring and alerting around capacity reconciliation problems
    Lessons

    Pausing one automated system does not stop the systems that feed it. Changes queued during the pause reflect the state at the time they were queued, and releasing the queue all at once applies those stale decisions together. The fixes OpenAI names are detecting state drift, making circuit breaker status visible, and preventing large batches from executing after a long pause.

  3. Symptoms

    From about 02:29 UTC on 24 September 2025, customers of Linode Kubernetes Engine (LKE) in US-Southeast (Atlanta) could not manage their clusters, and autoscaling was impacted. Internal logs showed 5xx errors whenever customers tried to manage LKE clusters associated with the affected cluster controller.

    Trigger

    Old certificates on the LKE cluster controllers were revoked at 02:29 UTC on 24 September 2025, after the expiring certificates had been rotated on 23 September.

    Root cause
    Component
    Contributing factor
    Remediation
    • deployed a fix for the certificate key mismatch
    • restarted the API endpoints
    Action items
    • Continue investigating the root cause and take preventive actions
  4. Symptoms

    Every service in the homelab Kubernetes cluster stopped answering: the V-Rising server, Grafana, Jellyfin and Linkding were all unreachable, and the Kubernetes API was down, so the cluster could not be managed at all. The outage was found by hand, about 3 hours after it began, when someone tried to use the services.

    Trigger

    A power outage forced the Kubernetes master node to reboot.

    Root cause
    Component
    Contributing factor
    Detection

    Manually, when someone tried to access the services; there were no automated alerts.

    Remediation
    • Connected a monitor to the master node and read the boot logs, which showed the kernel panic
    • Booted the previous kernel version, which brought the system back
    • Removed the broken Nvidia packages with sudo apt-get remove --purge '^nvidia-.*' and ran sudo dpkg --configure -a
    • Found remaining broken packages with dpkg -l | grep -v ^ii and removed them by hand
    • Ran sudo apt-get install -f and reinstalled linux-headers-$(uname -r)
    • Rebooted and confirmed the kernel panic was gone
    Action items
    • Make sure GPU driver installations fully succeed, or revert immediately when they fail
    • Move the cluster to a high-availability control plane
    • Expose the Kubernetes API through a load balancer in the HA setup
    • Set up a ticketing system to record incidents and their resolution
    • Write predefined troubleshooting workflows to shorten response time
    • Add infrastructure monitoring such as Prometheus and Grafana
    • Add blackbox HTTP and TCP checks from outside the cluster for critical services
    Lessons

    A driver installation that fails half-way can leave kernel packages broken without any visible effect until the next reboot, which may come weeks later and at the worst time. A failed DKMS build should be fixed or reverted at once. With a single master node and no monitoring from outside the cluster, one unbootable machine meant a total outage that nobody was told about; the fix itself was simple once the boot logs were seen.

  5. Symptoms

    Event ingestion and the Honeycomb UI in EU1 became unavailable at 22:00:10 UTC on April 9, 2024, and the status page reported that the EU1 instance was down. Both the ingestion service and the service behind the web UI stopped at roughly the same moment.

    Trigger

    A routine system update to the Kubernetes cluster, rolled out earlier on April 9, followed by a regular deployment that replaced pods one at a time.

    Root cause
    Component
    Contributing factor
    Detection

    The first status post, saying the EU1 instance was down, went up at 15:08 PDT (22:08 UTC), about 8 minutes after the outage began. There was no alerting on the AWS Load Balancer Controller.

    Remediation
    • Restarted the AWS Load Balancer Controller
    • Rolled back the Kubernetes cluster system update
    Action items
    • Find the exact cause of the failure so the system update can be deployed safely
    • Add monitoring and alerting on the AWS Load Balancer Controller so on-call engineers learn of a failure quickly and can pause deployments
    Lessons

    A rolling deployment can look healthy while the component that wires new pods into the load balancer is broken; the failure only shows when the last old pod goes away. Honeycomb now treats the AWS Load Balancer Controller as a critical component that needs its own alerting, so deployments can be paused before they remove the last pods that still receive traffic. Extensive testing in development and staging did not reveal the bad interaction.

Check your cluster for this

These 11 cases involve Ingress controller and Cloud load balancer. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause4

Breaking change in an upgrade3 cases

  1. IL-0098 After 2i2c moved from ingress-nginx to nginx-ingress, a hub's Ingress took priority over cert-manager's temporary Ingress for the same host, so new hubs could not get TLS certificates
    2i2c2026
  2. IL-0203 A routine Kubernetes cluster system update made the AWS Load Balancer Controller fail, so new pods were never registered with the ALB and Honeycomb's EU1 ingest and UI went down once the last old pods were replaced
  3. IL-0198 An automatic Ubuntu security update restarted systemd-networkd, which flushed the IP rules Cilium relied on and cut more than 60 percent of Datadog's Kubernetes nodes off the network across regions and cloud providers

Software defect4 cases

  1. IL-0124 Capacity changes queued while a circuit breaker was engaged ran all at once when it was released, taking multiple OpenAI inference engines out of service and raising API error rates
    OpenAI2026
  2. IL-0138 A failed Nvidia driver build left broken kernel packages on the only Kubernetes master node, which hit a kernel panic on reboot after a power outage and took the homelab cluster down for six days
  3. IL-0106 A malformed Traefik IngressRoute triggered a Traefik v2 bug once a node rollover restarted every Traefik pod, and all Kubernetes services returned 404
    DFDS2021
  4. IL-0032 Mutating admission controller generated broken JSON patches, silently blocking deploys for a week until a production service ran down to two pods
    Airbnb2020

Certificate or credential expiry1 case

Contributing factor
Organisation
  1. IL-0156 Revoking old certificates after a rotation left a certificate key mismatch between API endpoints and the cluster controller, and LKE cluster management and autoscaling in Atlanta returned 5xx errors
    Linode2025

Configuration change3 cases

  1. IL-0153 DOKS worker nodes went NotReady at 06:00 UTC on three days because a systemd timer in the Debian image ran apt upgrade and killed it mid kernel upgrade, breaking node networking
  2. IL-0177 WebSocket connections to LINE's messaging-hub on Kubernetes dropped all at once whenever another service's change reloaded a shared HAProxy L7 load balancer, and the reconnect wave overloaded a token API and filled nf_conntrack on Nginx
    LINE+2022
  3. IL-0066 Broken ConfigMap change lay dormant for weeks, then took down Pusher's edge proxy when a cluster upgrade replaced its pods
    Pusher2019