Incident Library
  • Root cause
  • Component
  • Symptom
  • Contributing factor
  • Case

Cases22 cases

11 to 15 of 22

  1. Symptoms

    At 13:02 UTC on 2024-01-23 DigitalOcean posted that, as of 12:18 UTC, its engineers were investigating an issue with Kubernetes clusters in the FRA1 region and that users might see errors when communicating with their clusters. The control planes of the affected DOKS (DigitalOcean Kubernetes) clusters had become inaccessible.

    Trigger

    An incorrect configuration was applied to an internal infrastructure cluster in FRA1 at 12:21 UTC during a maintenance operation.

    Root cause
    Component
    Contributing factor
    Detection

    Engineers were investigating errors with Kubernetes clusters in FRA1 as of 12:18 UTC and identified the incorrect configuration as the cause at 12:36.

    Remediation
    • restored each affected cluster's etcd from its latest twice-daily backup
    • restored the stateless control plane components after etcd
    • patched the recovery mechanism after unexpected problems during recovery
    • found and fixed an additional small bug during recovery
    • contacted affected customers directly with further instructions, since some might need to reconfigure Kubernetes resources
    Action items
    • Prevent automatic deletion of infrastructure cluster resources under any circumstances in the production environment
    Lessons

    When managed control planes run as resources in another cluster, one configuration mistake in that cluster can delete hundreds of control planes at once through ordinary automation. The etcd backups limited the damage, but their twice-daily schedule set the worst case at 12 hours of lost control plane state, and the recovery tooling itself needed patching during the incident.

  2. Symptoms

    From about 10:30 UTC on 30 August 2023, customers had trouble accessing or using Azure, Microsoft 365 and Power Platform services in Australia East. The affected Azure services included Azure Kubernetes Service (AKS) along with storage, SQL Database, Cosmos DB, virtual machines and Azure Resource Manager.

    Trigger

    At 08:41 UTC a lightning strike on electrical infrastructure about 18 miles away caused a utility voltage sag that shut down the cooling chillers of datacenters in one Australia East availability zone; 13 chillers failed to restart automatically and five could not be restarted, so two data halls overheated and their infrastructure was shut down.

    Root cause
    Component
    Contributing factor
    Detection

    Cosmos DB impact was detected by monitoring at 10:47 UTC, first automated communications went to Azure Service Health at 10:48 UTC, the public Azure Status page was updated at 11:30 UTC, and all subscriptions in Australia East were sent portal communications at 11:36 UTC.

    Remediation
    • shut down the remaining networking, compute and storage in the two affected data halls so the chilled water loop could cool down
    • restarted the five chillers manually at 12:12 UTC
    • restored power to all hardware by 15:10 UTC and brought infrastructure back in phases
    • restored AKS operations through the recovery of the SQL Database operation queue, with no other mitigation
    Action items
    • AKS: convert all operation queue SQL Database databases to be zone redundant (estimated September 2023)
    • AKS: replace all cross-region SQL Database queue usage with zone-redundant Service Bus queues (estimated September 2023)
    • Change the control timing logic of the Chiller Management System so chillers do not fail to restart after voltage fluctuations
    • Change the emergency procedure for manual restarts of simultaneous chiller failures from an adjacent sequence to a load-based sequence per data hall
    • Increase technician staffing at the datacenter as a temporary measure for manual chiller restarts
    • Storage: optimise the large-scale recovery process and update troubleshooting guides (estimated December 2023)
    • Azure Service Fabric: improve reliability of SQL Database tenant ring recovery (estimated December 2023)
    • SQL Database: review the trigger criteria of auto-failover groups (estimated October 2023)
    • SQL Database: upgrade internal tooling to enable mass migration of databases (estimated December 2023)
    • Cosmos DB: optimise Service Managed Failover for single-region-write accounts (estimated November 2023)
    • ARM: complete the migration of its storage layer to the zonally redundant architecture (estimated December 2023)
    • Incident management: harden readiness, process and playbook for power-down scenarios (estimated October 2023)
    Lessons

    A control plane spread across availability zones still fails with a zone when one of its dependencies, here the SQL Database operation queue, is not zone redundant. When a second region uses the same database, the failure crosses into that region as well. Workloads already running were not expected to be affected; what stopped was everything that needs the managed service's control plane, such as scaling and cluster changes.

  3. Symptoms

    A tech support engineer called Palark to say that a customer's cluster, production environment included, had practically stopped working. On the control plane nodes the kube-apiserver processes had used up all the memory and were crashing and restarting over and over, so the Kubernetes API was unreachable and completely non-functional.

    Trigger

    Cilium agent pods on more than 200 nodes sent LIST requests to the Kubernetes API en masse at the same time.

    Root cause
    Component
    Contributing factor
    Detection

    A tech support engineer phoned the team to report that the customer's cluster was practically non-operational.

    Remediation
    • added CPU and memory to the control plane nodes in two steps, from 8 CPUs and 16 GB of RAM to 16 CPUs and 64 GB, until the API stabilised
    • restarted the Cilium agents in a test window agreed with the customer to reproduce the memory growth
    • deployed a FlowSchema and a PriorityLevelConfiguration named cilium-pods that limit and queue LIST requests from the Cilium service accounts to cilium.io resources
    • reduced the control plane nodes back to their original resources
    Action items
    • Make an API Priority and Fairness configuration a standard part of Palark's Kubernetes platform
    Lessons

    In a large cluster, many agents sending LIST requests at once can exhaust kube-apiserver memory, and with several API servers the crash moves from one to the next. APF can hold back such a client: a FlowSchema matches its requests and a PriorityLevelConfiguration gives them a small concurrency share and a queue, so the requests run more slowly instead of all at once. With APF enabled, the total concurrency it divides is the sum of --max-requests-inflight (default 400) and --max-mutating-requests-inflight (default 200), shared among priority levels in proportion to their assured concurrency shares, so raising one level's share lowers every other level's limit. Long-running requests such as logs and exec, and WATCH requests, are not subject to APF. The response headers X-Kubernetes-PF-FlowSchema-UID and X-Kubernetes-PF-PriorityLevel-UID show where a request landed, and the metrics Apiserver_flowcontrol_rejected_requests_total, Apiserver_current_inqueue_requests and Apiserver_flowcontrol_request_execution_seconds, with the debug endpoints /debug/api_priority_and_fairness/dump_priority_levels and /debug/api_priority_and_fairness/dump_queues, show how the queues behave.

  4. Symptoms

    At 14:11 UTC on May 25, 2023, Linode learned that part of its LKE users in the Frankfurt data center could not reach their kube-apiservers through kubectl. The status page opened at 14:27 UTC with "We are investigating reports of connectivity issues with the LKE service within the Frankfurt Datacenter".

    Root cause
    Component
    Contributing factor
    –
    Detection

    Linode was made aware of the problem at 14:11 UTC; the status page refers to reports of connectivity issues.

    Remediation
    • increased memory limits
    Action items
    • Increase resilience, redundancy and monitoring for the LKE components affected by the incident
  5. Symptoms

    One evening, right after an ordinary restart of kube-apiserver in a customer's production cluster, etcd memory consumption rose almost threefold. The sudden growth led to a cascading restart of all the master nodes.

    Trigger

    An ordinary restart of kube-apiserver, after which every pod of the log collector DaemonSet sent its list requests at the same time.

    Root cause
    Component
    Contributing factor
    Detection

    Memory graphs showed etcd memory on the master nodes almost tripling after a kube-apiserver restart; the audit logs then pointed to one DaemonSet's list requests.

    Remediation
    • created a PriorityLevelConfiguration named limit-list-custom that queues requests (assuredConcurrencyShares 5, 16 queues, handSize 4, queueLengthLimit 50)
    • created a FlowSchema that routes list and get requests on pods from the log collector's service account to that priority level
    Action items
    • Submit a pull request adding resource version support to the Kubernetes Rust library
    • Open a pull request to the Vector log collector to address the startup list requests
    • Apply the same flow-control approach to a similar problem found with the Cilium CNI
    Lessons

    A field selector reduces what kube-apiserver returns, not what it reads from etcd: listing the pods of one node still reads every pod in the cluster. A DaemonSet whose pods all list at startup multiplies that by the node count each time kube-apiserver restarts. Where exact freshness is not needed, resourceVersion=0 lets kube-apiserver answer from its cache; where the client cannot set it, API Priority and Fairness can queue the requests so they reach etcd gradually.

Check your cluster for this

These 22 cases involve Kubernetes API server and etcd. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause9

Dependency failure2 cases

Organisation
  1. IL-0133 A storm shut down cooling at Nebius's us-central1 data center, and a disk hot-plug bug kept Managed Kubernetes control planes down for hours after power returned
    Nebius2026
  2. IL-0162 LKE users could not reach their cluster control planes or the LKE Dashboard because an earlier database update made the internal LKE DNS service hang
    Linode2025

Faulty deployment1 case

Organisation
  1. IL-0160 A repaired legacy GPU monitoring script sent a firmware query that triggers a race condition in the GPU System Processor of NVIDIA RTX 4000 Ada GPUs, locking up GPU Linodes and LKE worker nodes in several regions
    Linode2026

Certificate or credential expiry3 cases

  1. IL-0183 kubeadm's one-year leaf certificates expired, so kube-apiserver could not reach etcd, restarted in a loop and left the cluster unreachable
  2. IL-0113 The managed GKE control plane of Webhook Relay's main cluster failed because its API server certificates had never been rotated, and a manual credential rotation reported success without taking effect
  3. IL-0184 JupyterHub's KubeSpawner could not create containers and kubectl was refused because the API server and other internal certificates of a kubeadm cluster had expired
    dbhang2021

Software defect2 cases

  1. IL-0138 A failed Nvidia driver build left broken kernel packages on the only Kubernetes master node, which hit a kernel panic on reboot after a power outage and took the homelab cluster down for six days
  2. IL-0077 EKS cluster went read-only for over seven hours after Kyverno ephemeralreports filled the etcd database past its size limit

Capacity exhaustion7 cases

  1. IL-0204 An etcd memory spike overloaded the control plane of a Render Frankfurt cluster, and DNS then failed because CoreDNS ran on the rebooted control plane nodes and could not start without the API server
    Render2024
  2. IL-0195 The kube-apiservers of a cluster with more than 200 nodes ran out of memory and crashed one after another under mass LIST requests from Cilium agents
    Palark2023
  3. IL-0165 Some LKE users in Frankfurt could not reach their kube-apiservers with kubectl after backend services failed under memory constraints
    Linode2023
  4. IL-0194 After a kube-apiserver restart, pod LIST requests from every pod of a Vector DaemonSet nearly tripled etcd memory and restarted all master nodes
    Palark2023
  5. IL-0076 Kubernetes masters went down after Dex filled etcd with AuthRequest objects and deleting its namespace started an endless list-and-timeout loop
  6. IL-0075 Kubernetes API servers pegged on CPU when the cluster grew to about 290 nodes, traced to Datadog agents polling the API
  7. IL-0031 Kubernetes API server OOM-killed, leaving the Skipper ingress without routes; the talk points to a misconfigured CronJob manifest

Configuration change4 cases

  1. IL-0005 A new telemetry service overloaded the Kubernetes API servers of large clusters and broke DNS-based service discovery for all OpenAI services
    OpenAI2024
  2. IL-0118 A global change to Kubernetes namespace labels made the networking layer recompute metadata and overwhelmed the control planes of three of OpenAI's largest GPU clusters
    OpenAI2024
  3. IL-0152 An incorrect configuration applied during maintenance made an internal infrastructure cluster automatically delete the control planes of 200 DOKS clusters in FRA1
  4. IL-0008 An unresponsive OPA validating webhook crash-looped the API server during a GKE master upgrade, and node auto-repair then recreated every node

DNS or network fault1 case

Contributing factor
–
Organisation
  1. IL-0154 Line cards on an SFO3 core router rebooted together and halved backbone capacity, and DOKS nodes whose guest networking did not recover stayed NotReady with degraded API servers until all affected nodes in the SFO3 DOKS fleet were recycled

Cloud provider outage1 case

Organisation
  1. IL-0145 A power sag and chiller failure in one Australia East availability zone took down the AKS control plane's compute and its non-zone-redundant SQL Database operation queue, blocking AKS create, update and delete operations in Australia East and Australia Southeast

unknown1 case

Organisation
  1. IL-0059 Single-master Kubernetes control plane kept dying because the kubelet restarted a healthy etcd on a failing kubeadm liveness probe