  1. Symptoms

    Google Kubernetes Engine (GKE) customers with Workload Identity enabled saw a high logging rate. Debug log lines containing the string "Unable to sync sandbox" were ingested into Cloud Logging, used up the Cloud Logging ingestion quota and, beyond the free monthly allotment, produced extra billable usage. Workload Identity is opt-in on GKE Standard and always enabled on GKE Autopilot.

    Trigger

    GKE clusters ran gke-metadata-server versions 0.4.272 to 0.4.280, which contained an incorrect configuration that wrote "Unable to sync sandbox" debug logs at a high rate.

    Root cause
    Component
    Contributing factor
    –
    Detection

    The first status update was posted at 13:32 US/Pacific on 2023-11-02, and the updates told customers how to check a cluster from the version annotation on the gke-metadata-server DaemonSet.

    Remediation
    • rolled out a fix across the GKE fleet so the excess logs were no longer ingested into Cloud Logging
    • offered GKE Rapid channel customers a control plane upgrade to 1.28.2-gke.1157000 or above, or 1.27.7-gke.1038000 or above, as a workaround
  2. Symptoms

    Request latency from the Temporal Server History service, the service that starts workflow executions and records their progress, was higher and less steady than it should be on a self-hosted Kubernetes deployment. The CPU dashboard showed the history pods using less than 60 percent of their CPU, yet the same pods were being throttled.

    Trigger

    Normal load on History pods that had a CPU limit of 2 cores on 8-core nodes, with the Go runtime's GOMAXPROCS left at its default of one per node core.

    Root cause
    Component
    Contributing factor
    Detection

    A Prometheus query for CPU throttling showed the history pods throttled although their CPU usage read under 60 percent.

    Remediation
    • set the GOMAXPROCS environment variable to 2 to match the 2-core CPU limit
    Action items
    • Set GOMAXPROCS automatically from the Kubernetes CPU limit, from Temporal release 1.21.0
    Lessons

    A CPU usage graph averaged over 15 seconds or more can sit far below 100 percent while a container is being throttled, so throttling needs its own metric. A Go program in a container should have GOMAXPROCS matched to its CPU limit, or to its CPU request when it has no limit. The author recommends not using CPU limits at all.

  3. Symptoms

    On a Friday afternoon a tenant of SCHIP, Adevinta's multi-tenant Kubernetes runtime, reported a spike of HTTP 5xx errors in some of its services. The drops in quality of service came back periodically through the following days, each one short, and were reported mostly around midnight.

    Root cause
    Component
    Contributing factor
    Detection

    A tenant reported a spike of HTTP 5xx errors in some of its services; the DNS Latency SLI had already been degraded for some time without being acted on.

    Remediation
    • raised the dnsmasq concurrent query limit from 150 to 1500
    • added a CoreDNS header block that sets the ra and aa flags and clears rd, so dnsmasq caches cluster.local answers
    • configured dnsmasq on each node to answer NXDOMAIN for unresolvable search-domain names instead of forwarding them to CoreDNS
    • changed the fluent-bit log router hostname to a fully qualified name
    • asked the affected tenants to use fully qualified names for internal calls
    Lessons

    The DNS Latency SLI had shown the problem long before anyone looked at it. An SLO only protects you when its SLIs are trusted and a drop is investigated. The investigation took a month partly because several on-call groups worked on it separately, without one place for observations and hypotheses, and sometimes chased hypotheses already discarded. Disprove one hypothesis before starting the next, and collect data the metrics system lacks: DNStop showed the garbage lookups that no dashboard did. With ndots:5, short service names multiply DNS traffic; a node-local cache only helps if it can cache the cluster DNS answers at all.

  4. Symptoms

    From 11:49 AM PDT on 13 June 2023, Lambda function invocations in the Northern Virginia (us-east-1) Region returned more errors and took longer. Customers that triggered functions from asynchronous or streaming event sources saw their event backlogs grow because the events were not being processed.

    Trigger

    At 11:49 AM PDT, while adding capacity for normal daily traffic growth, the Lambda Frontend fleet in one cell crossed a capacity threshold that no single cell had reached before.

    Root cause
    Component
    Contributing factor
    Detection

    Engineering teams were engaged immediately and began investigating; by 12:26 PM PDT they had identified the latent defect and its effect on provisioning compute capacity.

    Remediation
    • scaled the Lambda Frontend fleet down to a size that no longer triggered the latent defect
    Action items
    • Disable the Lambda Frontend scaling activities that triggered the event
    • Fix the latent bug and deploy the fix to all Regions
    • Complete action items addressing the immediate concern with cellular scaling
    • Bound all cells to a well-tested size to avoid unexpected scaling issues
    Lessons

    A fleet that scales automatically can grow into a size that was never tested, and a defect that only appears at that size stays hidden until ordinary daily growth reaches it. AWS's answer is to cap every cell at a well-tested size. For EKS users, the event shows that provisioning new clusters in us-east-1 depended on Lambda, while clusters that were already running were not affected.

  5. Symptoms

    The graph of WebSocket connections to messaging-hub, the messaging platform used by the Japanese food delivery service Demaecan, showed sudden deep drops even outside peak traffic. The drops kept coming back at irregular intervals. Messages still reached clients, because messaging-hub switches to Firebase Cloud Messaging when a WebSocket is gone.

    Trigger

    Another service that shared the same L7 load balancer deployed its own load balancer configuration in the Verda dashboard, which reloaded HAProxy; 30 minutes later, at the hard-stop-after limit, the old HAProxy process exited and closed every WebSocket connection it still held.

    Root cause
    Component
    Contributing factor
    Detection

    The developer noticed deep, sudden drops in the WebSocket connection graph that were not tied to peak traffic and kept recurring irregularly. The Nginx packet drops were found through network monitoring.

    Remediation
    • separated the Merchant system's token issuance API into its own deployment so reconnect traffic did not delay other Merchant APIs
    • scaled out Nginx with pod anti-affinity and a label selector so each pod ran on a different node, which stopped the nf_conntrack packet drops
    • raised Ingress Nginx proxy-read-timeout and proxy-send-timeout and the load balancer timeout to 3600s, which did not stop the drops
    • moved messaging-hub from the shared L7 load balancer to an L4 load balancer, which ended the WebSocket drops
    Lessons

    A reload of a shared load balancer by a different team can cut long-lived connections, and with hard-stop-after the cut comes 30 minutes later, far from the change that caused it. The author's lesson is not to narrow the scope of the search too early: trusting that the infrastructure was fine kept the investigation inside the team's own systems for days. A reconnect wave from many WebSocket clients can overload the systems that issue connection tokens and fill nf_conntrack on proxy nodes. Scaling Nginx out only helps for conntrack if the pods land on different nodes, and anti-affinity leaves extra replicas Pending once they outnumber the nodes. That messaging-hub problems can still load the connected systems remains an open problem.

Check your cluster for this

These 36 cases involve Application database and In-memory cache. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause7

Faulty deployment1 case

Organisation
  1. IL-0136 A deployment that cleared an internal service's caches at peak traffic sent 20 times the normal load to the Azure OpenAI metadata backend in Sweden Central, and health checks that depended on its database restarted instances in a loop for almost six hours

Software defect10 cases

  1. IL-0124 Capacity changes queued while a circuit breaker was engaged ran all at once when it was released, taking multiple OpenAI inference engines out of service and raising API error rates
    OpenAI2026
  2. IL-0150 A latent race condition in DynamoDB's DNS automation left an empty DNS record for dynamodb.us-east-1.amazonaws.com, and the DynamoDB and EC2 launch failures that followed caused EKS, ECS and Fargate container launch failures and cluster scaling delays in us-east-1
  3. IL-0081 API requests timed out during deployment rollouts because the ingress-nginx enable-serial-reloads option held back endpoint updates while a long NGINX reload was running
    Cresta2025
  4. IL-0131 A new kind of GenerateContent request made Vertex AI prediction API servers segfault, and once enough of them restarted at the same time the serving fleet could not carry the load
  5. IL-0024 Expensive cache-backed API calls and uncancelled database requests overloaded MongoDB and took the Hugging Face Hub down three times
  6. IL-0141 gke-metadata-server versions 0.4.272 to 0.4.280 flooded Cloud Logging with "Unable to sync sandbox" debug logs on GKE clusters with Workload Identity, using up logging quota and adding billable usage
  7. IL-0151 A latent defect in the AWS Lambda Frontend, set off when one us-east-1 cell scaled past a size never reached before, raised errors for Lambda and for services that depend on it, including new EKS cluster provisioning
  8. IL-0029 Slow user-facing services from CPU throttling on containers that used far less CPU than their limit
    Buffer2020
  9. IL-0012 CPU limits and an unpatched kernel CFS quota bug throttled multi-threaded services into stalls, failed health checks and timeouts
    Omio2020
  10. IL-0011 HAProxy ingress piled requests onto the same pods because a Go template visited the backend map in sorted pod IP order

Capacity exhaustion11 cases

  1. IL-0181 A traffic spike from an external community post pushed product API pods into CPU throttling under a 1-core limit, and an e-commerce product page slowed down while every pod stayed Running
    Kevin2026
  2. IL-0100 PostHog's feature flags pods were packed onto Kubernetes nodes that were too small for their CPU requests, and CPU saturation above 90% caused three outages in ten days through Redis overload, connection pool exhaustion and slow queries
  3. IL-0082 Losing one CoreDNS pod during a planned EKS node reroll overloaded the remaining CoreDNS pods, causing DNS timeouts and errors across multiple services at RebelMouse
  4. IL-0027 All CoreDNS pods landed on one node, the node ran out of memory, and DNS for the whole service went down
  5. IL-0182 Too few CoreDNS replicas on EKS were overloaded during traffic spikes, raising latency and cutting the network for task pods, and the over-provisioned, tightly spread CoreDNS pods added later blocked Karpenter consolidation
  6. IL-0202 A burst of queries and database writes exhausted connection pools and memory on Honeycomb's ingest hosts, and Kubernetes crash-loop back-off kept failed hosts offline so ingest capacity stayed too low to recover
  7. IL-0028 Temporal History service latency rose because its pods were CPU-throttled while CPU usage read below 60 percent
  8. IL-0140 The GKE API in us-central1 returned errors and high latency for 3 hours 19 minutes after an unexpected rise in backend traffic that client retries made worse
  9. IL-0206 Consul agents in GitLab.com's GKE pods were repeatedly OOM-killed, so the Rails pods lost database replica discovery and sent every query to the primary
    GitLab2022
  10. IL-0033 Uneven load across kube-dns pods and a DNS packets-per-second limit pushed service latency to 20 seconds
    Airbnb2019
  11. IL-0075 Kubernetes API servers pegged on CPU when the cluster grew to about 290 nodes, traced to Datadog agents polling the API

Configuration change7 cases

  1. IL-0063 VPN outage after recreating a Redis StatefulSet restarted the whole Redis cluster without readiness checks
  2. IL-0118 A global change to Kubernetes namespace labels made the networking layer recompute metadata and overwhelmed the control planes of three of OpenAI's largest GPU clusters
    OpenAI2024
  3. IL-0177 WebSocket connections to LINE's messaging-hub on Kubernetes dropped all at once whenever another service's change reloaded a shared HAProxy L7 load balancer, and the reconnect wave overloaded a token API and filled nf_conntrack on Nginx
    LINE+2022
  4. IL-0208 A GitLab chart bump that renamed Kubernetes Service and Deployment ports made the GCP load balancer reconfigure, and GitLab.com slowed down and returned intermittent 50x errors
    GitLab2022
  5. IL-0209 A too-high HPA CPU target kept GitLab.com web pods from scaling up as traffic moved from VMs to Kubernetes, breaching the web latency SLO for 15 minutes
    GitLab2021
  6. IL-0189 A JVM service moved from EC2 to Kubernetes answered up to ten times slower because KIAM's 15-minute credentials made the AWS Java SDK fetch new credentials on every request
  7. IL-0035 Worker nodes went NotReady after a new ElastAlert rule without memory limits used up node memory
    NU.nl2019

Cloud provider outage2 cases

Organisation
  1. IL-0084 Packet drops on a bare metal provider's vSwitch forced Namespace to rebuild its fra3 region and left global capacity short, and the next day slow NVMe writes on a control plane node drove the Kubernetes API server to very high CPU
  2. IL-0205 The GKE cluster autoscaler could not add nodes to GitLab.com's production cluster because Google Cloud ran out of SSD persistent disks in us-east1
    GitLab2021

DNS or network fault4 cases

  1. IL-0083 Intermittent 5xx errors in a multi-tenant Kubernetes cluster came from internal DNS: the node-local dnsmasq hit its 150 concurrent query limit, did not cache cluster.local answers, and ndots search lookups flooded CoreDNS
  2. IL-0056 Calls from EKS pods to services behind an NLB in another VPC failed intermittently because the AWS VPC CNI did source NAT on the node
  3. IL-0057 Higher p99 latency after moving a reverse proxy to EKS, from outgoing connections delayed by a SNAT conntrack race
    Prezi2019
  4. IL-0047 Pod-to-pod requests delayed by 5, 10 or 15 seconds because of DNS lookups lost to a conntrack race

Dependency failure1 case

Organisation
  1. IL-0073 Intermittent Kafka connectivity overloaded Docker daemons, set off a node rescheduling cascade and poisoned the Consul gossip mesh
    Target2019