Cases2 cases
1 to 2 of 2
IL-0347About 25% of Scaleway FR-PAR-1 hypervisors lost VPC connectivity when both VPC BGP route reflectors got stuckScaleway2024- Symptoms
On 18 October 2024, from 7:50 to 8:01 UTC, about 25% of the hypervisors in Scaleway's FR-PAR-1 availability zone lost VPC connectivity with the rest of the region, and products that use VPC failed with them. Public internet connectivity and Elastic Metal VPC connectivity were not affected.
- Trigger
At 6:20 UTC a Top of Rack switch in FR-PAR-1 had a software crash. One of the two BGP route reflectors for VPC ran on a hypervisor in that rack and was left in an abnormal state.
- Root cause
- Component
- Contributing factor
- Detection
Health-check monitoring on both route reflectors detected the anomaly, and the Scaleway Customer Excellence and SRE teams detected the customer impact and opened an incident.
- Remediation
- Fixed both VPC route reflectors by manual action
- Action items
- Fixed the autohealing mechanism that had failed to fix route reflectors stuck in a stale state; the fix is https://github.com/FRRouting/frr/pull/17163
- Run different software versions on the route reflectors so a single bug cannot stop several instances
- Investigate the software issue that left the route reflectors in a stale state
IL-0263GitHub was slow and erroring all day and down for 18 minutes as links between access and aggregation switches saturatedGitHub2012- Symptoms
On Friday, 30 November 2012, GitHub had sporadic bursts of slow responses and intermittent errors for the whole day and was completely unavailable for 18 minutes. One fileserver pair was offline for a large part of the day, which affected a small percentage of repositories; this was a side effect of the network problems on the high-availability clustering between the fileserver nodes.
- Trigger
On the morning of 30 November GitHub moved the A switches in its server cabinets onto the new aggregation switches, the second half of a migration whose B-switch half had been done the day before.
- Root cause
- Component
- Contributing factor
- Detection
Engineers saw the problems during the maintenance itself: connectivity to the B switch was lost as the last A switch was connected, and afterwards performance stayed low and the links between access and aggregation switches showed as completely saturated.
- Remediation
- Fixed the bridge-loop problem and returned the affected B switch to service
- Removed the partial link failure detection setting from the access switches
- Escalated to the network vendor, which raised the case to its highest severity level
- Restarted core processes on the aggregation switches in a Saturday 0600 Pacific maintenance window so they learned MAC addresses again
- Action items
- Deploy the vendor's software update that fixes the MAC learning issue to the switches
- Closely monitor aggregation-to-access capacity and keep a workaround process ready if the problem returns
- Build a duplicate of the network stack, from the routers through the access switches, as a staging environment for testing such changes
- Add automated network monitoring that alerts sooner on similar issues
- Run scheduled incident response exercises with scenarios that counter tunnel vision
- Contact the network vendor's support at the first sign of trouble in the network
- Lessons
GitHub had designed the maintenance to have no impact on customers and clearly failed, so it plans to invest in a staging copy of its network to test such changes and catch bugs like this one. During the response the team fixated for a long time on a bridge loop, which kept it from considering other causes. GitHub had a very positive experience with the vendor's support staff, so it will contact that support team at the first sign of network trouble.
These 2 cases involve Network switch and BGP routing. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.
By root cause1
Software defect2 cases
- Component
- Contributing factor