  1. Symptoms

    On 16 May 2025, in Neon's Kubernetes cluster in AWS us-east-1, new compute pods were scheduled but could not start and failed with IP allocation errors. Each Neon compute is a Postgres database running in a lightweight virtual machine in its own pod, so without new pods, idle customer databases could not be woken up.

    Trigger

    On 16 May the Neon control plane's periodic job that terminates idle computes started failing. Compute creations continued, and the number of active computes rose from about 5k to about 8.1k within minutes. On 19 May, a follow-up change that set WARM_IP_TARGET back to 1 started the second round of failures.

    Root cause
    Component
    Contributing factor
    Detection

    As cluster-autoscaler added nodes, the team saw IP allocation errors on new pods that were scheduled but could not start. The rate of successful pod starts and VPC subnet metrics were then used to follow the problem.

    Remediation
    • Set WARM_IP_TARGET=1 to release IPs held by nodes without free CPU or memory
    • Fixed the control plane's periodic job so idle computes were terminated again
    • Restarted the aws-node DaemonSet several times, each with a temporary improvement
    • Set WARM_IP_TARGET=0, MINIMUM_IP_TARGET=0 and WARM_ENI_TARGET=0, which let nodes allocate enough IPs and stabilised the cluster
    • On 19 May, set WARM_IP_TARGET back to 0 after setting it to 1 failed again
    • Enlarged the pool of pre-created warm compute pods to absorb failed pod starts
    Action items
    • Open a pull request to AWS CNI to improve how ipamd releases IPs in this situation
    • Follow up with AWS Support about the roughly 100 subnet IPs that were never allocated, for reasons Neon could not explain
    • Change the architecture to support horizontal scaling
    Lessons

    With default settings AWS CNI can keep many IPs on nodes that cannot use them, so the share of subnet IPs assigned to pods does not tell how close the subnet is to running out. WARM_IP_TARGET and WARM_ENI_TARGET follow different logic, a warm IP target of zero switches to the ENI logic, and IPs in cooldown count toward the target, which behaves badly under high pod churn. Changing these settings during an incident without knowing that logic prolonged the outage, and reverting a setting did not bring back the earlier healthy state.

  2. Symptoms

    At 08:29 UTC on 22 June 2021 alerts fired because all services in the Kubernetes cluster were returning 503. No inbound traffic was reaching the cluster. A customer reported the problem at 08:32.

    Trigger

    The pipeline replaced the AWS VPC CNI as part of a refactoring that moved EKS add-ons from kubectl to native Terraform management.

    Root cause
    Component
    Contributing factor
    Detection

    Alerts fired at 08:29 UTC, eight minutes after the VPC CNI was replaced; a customer reported the issue at 08:32.

    Remediation
    • committed a fix that reverted the infrastructure-modules reference
    • re-triggered the pipeline after it failed on an AWS API timeout
    • let the pipeline reattach the target groups to the ALB
    Action items
    • Revert the ALB de-registration delay to the default of 300 seconds
    • Update the roll-over script to set the ALB de-registration delay to zero temporarily before a roll-over
    • Create an ingress test suite
    Lessons

    The change to the de-registration delay had been weighed mainly for performance. Critical pipeline runs should be watched while they run. Everyone should receive the alerts and react to them, and alert messages that were unclear should be reworded.

  3. Symptoms

    On the Saturday the production cluster was moved from kops to EKS, the platform became very slow and too unstable to keep running, and the team reverted.

    Trigger

    Production was moved from a kops cluster using Weave networking to a new EKS cluster using the AWS VPC CNI, without external SNAT enabled.

    Root cause
    Component
    Contributing factor
    Detection

    The team lead saw the platform behaving very slowly after the switch to EKS and phoned the author.

    Remediation
    • reverted production to the kops cluster
    • set AWS_VPC_K8S_CNI_EXTERNALSNAT=true in the AWS VPC CNI
    Action items
    • Monitor and alert on the AWS VPC CNI
    Lessons

    In a networking problem every component in the stack is a suspect; ruling out EKS early cost a lot of time. A DaemonSet that pinged every component from every other one exposed the anomaly that led to the fix. The team had only skimmed the AWS CNI documentation before the migration; knowing how the plugin works internally would have led to better judgements and hypotheses while debugging.

Check your cluster for this

These 3 cases involve AWS VPC CNI and Cloud load balancer. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.