Incident Library
Applied filters FactorUnverified assumptionClear allEvery case under the filters, with no sentence; newest first.
Suggested filters Search, and the values found in your words appear here.

Graph

  • Root cause
  • Component
  • Symptom
  • Contributing factor
  • Case

Cases35 cases

1 to 5 of 35

  1. Symptoms

    The on-call engineer for a high-traffic service was alerted that requests were failing in large batches every 30 seconds.

    Trigger

    DEBUG level logging was on in production when traffic surged, raising log volume to about 100 times normal while the service logged synchronously.

    Root cause
    Component
    Contributing factor
    Detection

    The on-call engineer was alerted that requests were failing in large batches every 30 seconds.

    Action items
    • Replace synchronous logging with TraceAwareAsyncAppender, which captures trace_id and span_id on the calling thread and drops logs instead of blocking when the queue is full (neverBlock=true)
    • Keep the amount of log output at a sustainable level, since an asynchronous queue still fills under sustained overload
    Lessons

    Removing AsyncAppender to keep trace IDs also removed the protection that kept request threads away from stdout back-pressure. A company-wide standard applies the same side effect to dozens of services, so check what a standard rests on and what working behaviour it takes away. ThreadLocal context does not cross into an asynchronous worker, but capturing it on the calling thread before handing the event off keeps both the IDs and the asynchronous output. Under extreme load, dropping log lines is preferable to stopping request handling.

  2. Symptoms

    After a rolling restart of the Argo CD application-controller, namespaces that several applications shared went into the Terminating state. About 97 applications were then stuck in a Missing/OutOfSync deadlock.

    Trigger

    A manual bulk sync with force: true from the Argo CD UI, run during the window after an application-controller restart, on an application whose manifests declared a namespace whose app.kubernetes.io/instance label pointed to a different application.

    Root cause
    Component
    Contributing factor
    Action items
    • Refile the problem as #29739: a manual force sync hard-replaces shared cluster-scoped resources through a tracking-ID conflict, ignoring Prune=false
    Lessons

    The sync option Prune=false only protects the prune path; it does not stop a force sync from deleting and recreating a resource. When two Argo CD applications declare the same namespace or other cluster-scoped resource, force-syncing the application that does not own the tracking label can delete it at any time.

  3. Symptoms

    At 15:10 (Bucharest time) on 2026-03-31 an alert fired for the prod hub on the berkeley-geojupyter cluster on AWS: "[FIRING:1] At least two servers failed to start in the last 30m cluster=berkeley-geojupyter hub=prod (provider=aws immediate action needed)". It opened PagerDuty incident #2057.

    Trigger

    An upgrade merged on 2026-03-30 bumped the cluster autoscaler version, and the new version was incompatible with Kubernetes 1.33, which the berkeley-geojupyter cluster still ran.

    Root cause
    Component
    Contributing factor
    Detection

    An alert that at least two servers failed to start in the last 30 minutes fired at 15:10 and opened PagerDuty incident #2057. The report notes it was triggered by an automatic health check run, not by users being unable to start servers.

    Remediation
    • upgraded the cluster's Kubernetes version from 1.33 to 1.34
    • downgraded the cluster autoscaler by one patch version to 9.55.0, the version meant for Kubernetes 1.34
    Action items
    • The change in https://github.com/2i2c-org/infrastructure/pull/8008 (the report gives only the link)
    • Use recurrent issues, such as the recurrent-k8s-aws-upgrades workflow, to standardize Kubernetes versions across clusters
    Lessons

    Because the context of the autoscaler bump was fresh, the team went down the right path from the start. The upgrade batches had been designed with only 1.32 clusters in mind, so the one 1.33 cluster was missed and got an incompatible autoscaler. 2i2c notes it was lucky that an automatic health check, not real users, hit the failure first.

  4. Symptoms

    From about 21:00 UTC on March 4, 2026, customers using Linodes backed by NVIDIA RTX 4000 Ada GPUs saw the GPUs lock up. At first the problem seemed limited to worker nodes of the Linode Kubernetes Engine (LKE); later Linode confirmed that every Linode with this hardware was affected, while Standard Compute and other GPU instances were not.

    Trigger

    Deployment of a repaired legacy GPU monitoring script, fixed during a routine improvement effort to restore a missing metric on internal observability dashboards.

    Root cause
    Component
    Contributing factor
    Detection

    Customers saw the lockups from about 21:00 UTC; the first status post went up at 02:07 UTC on March 5, about 5 hours after the lockups began.

    Remediation
    • Disabled the monitoring script across the GPU fleet
    • Rebooted the affected nodes
    Action items
    • Take improvement and prevention measures to stop a recurrence; the postmortem does not list them
    Lessons

    A monitoring script can take down the hardware it watches. A fix meant only to restore a missing metric brought back a firmware query written for an earlier GPU generation, and on the RTX 4000 Ada architecture that query against an active GPU triggers a lockup. The script ran across the GPU fleet, so every Linode with this GPU was affected in several regions, and the investigation first suspected a regression in the host hypervisor or the GPU firmware.

  5. Symptoms

    The day began with an alert that several instances of the Redis cluster were running out of disk space. That part was fixed quickly. The outage came an hour later: right after the Redis StatefulSet was deleted and recreated at 8:10 UTC, Kubernetes restarted every Redis pod within about five minutes, and problems started to appear.

    Trigger

    To make Git match the volumes that had been resized by hand, the Redis StatefulSet was deleted with orphan (non-cascading) deletion and recreated with the new storage template; Kubernetes reconciled the new spec by restarting the entire Redis cluster.

    Root cause
    Component
    Contributing factor
    Detection

    An alert about Redis instances running out of disk space started the work; the outage itself showed up as backend errors about Redis connections right after the StatefulSet was recreated.

    Remediation
    • made the Redis masters forget obsolete node identities, reset the affected replicas and rejoined them, then waited for replication to catch up
    • identified the component that was actually running out of memory, scaled the backend service and raised memory limits for that component
    • temporarily relaxed probes so backend instances took traffic immediately instead of flapping between ready and not ready
    • reverted the temporary workarounds at 10:00 UTC
    Action items
    • Add startup probes so a Redis pod is not marked ready until its dataset is loaded
    • Build an own control plane for Redis that handles restarted pods stuck to an old master address
    • Reduce dependence on the single Redis cluster: move some important data to other stores, such as a separate Redis cluster per server, and use Kafka for some backend components
    Lessons

    The disk resize was not the problem; the cleanup afterwards was. An immutable field pushes operators toward deleting and recreating the controller, and that can set off a full reconcile. Startup and readiness probes are what slow a rolling restart down to a safe pace; without them a distributed store restarts in the most fragile way. Recovery plans must expect a cluster to heal slowly, and dependent services need to degrade gracefully while it does.

Check your cluster for this

These 35 cases involve Telemetry agent and Application database. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause10

Configuration change9 cases

  1. IL-0179 With DEBUG logging and synchronous log output, a high-traffic service filled the 64 KB stdout pipe, so request threads blocked in write() while holding database connections and HikariCP ran dry, failing requests in 30-second bursts
  2. IL-0063 VPN outage after recreating a Redis StatefulSet restarted the whole Redis cluster without readiness checks
  3. IL-0192 A Crossplane composition merge-policy change for a TLS policy update switched Kubernetes Services from LoadBalancer to ClusterIP and deleted the load balancers behind about 25% of Grafana Cloud services
  4. IL-0177 WebSocket connections to LINE's messaging-hub on Kubernetes dropped all at once whenever another service's change reloaded a shared HAProxy L7 load balancer, and the reconnect wave overloaded a token API and filled nf_conntrack on Nginx
    LINE+2022
  5. IL-0209 A too-high HPA CPU target kept GitLab.com web pods from scaling up as traffic moved from VMs to Kubernetes, breaching the web latency SLO for 15 minutes
    GitLab2021
  6. IL-0105 Replacing the AWS VPC CNI during a Terraform refactoring detached the ALB target groups, and every service in the Kubernetes cluster returned 503
    DFDS2021
  7. IL-0108 An Alcide admission controller applied to the production cluster during a workshop made create and update requests on Deployments time out
    DFDS2020
  8. IL-0061 A Terraform pull request merged out of order deleted a production GKE cluster, and recreating it deleted a second one
  9. IL-0066 Broken ConfigMap change lay dormant for weeks, then took down Pusher's edge proxy when a cluster upgrade replaced its pods
    Pusher2019

Software defect8 cases

  1. IL-0058 Argo CD deleted namespaces shared by several applications, leaving about 97 applications stuck Missing and OutOfSync
  2. IL-0171 Karpenter node auto-repair replaced EKS GPU nodes about 10 minutes after they became Ready, in a loop, because the Bottlerocket NVIDIA AMI lacked libdcgm.so and set AcceleratedHardwareReady to False
    Inflab2025
  3. IL-0029 Slow user-facing services from CPU throttling on containers that used far less CPU than their limit
    Buffer2020
  4. IL-0196 Adding a second Redis replica and lowering memory limits in one RedisFailover change restarted the only Redis pod that held data, and Sentinel promoted the empty new replica, erasing the data
    Palark2020
  5. IL-0062 Intermittent 502 errors behind a GKE Ingress because pods shut down before the load balancer stopped sending them traffic
  6. IL-0011 HAProxy ingress piled requests onto the same pods because a Go template visited the backend map in sorted pod IP order
  7. IL-0050 Pods on Kubernetes failed to resolve an external Redis hostname because of ndots:5, the musl resolver in Alpine images, and Netty's DNS resolver
  8. IL-0051 A third-party log shipping client leaked file descriptors with every new container until nodes failed with too many open files

Breaking change in an upgrade1 case

Organisation
  1. IL-0097 A cluster autoscaler version bump was incompatible with the one cluster still on Kubernetes 1.33, so no scale-up events fired and new nodes were not created
    2i2c2026

Faulty deployment3 cases

  1. IL-0160 A repaired legacy GPU monitoring script sent a firmware query that triggers a race condition in the GPU System Processor of NVIDIA RTX 4000 Ada GPUs, locking up GPU Linodes and LKE worker nodes in several regions
    Linode2026
  2. IL-0188 Rolling updates on EKS returned 502 errors for about 30 seconds because Kubernetes deleted old pods as soon as new pods passed readiness, before the ALB had marked the new pod targets healthy
  3. IL-0034 A crashing stats agent sidecar marked every pod unready and the service mesh pulled all services out of traffic
    Airbnb2019

Capacity exhaustion6 cases

  1. IL-0129 Throughput of the 384-GPU SmolLM3 pretraining run collapsed because shared WekaFS storage evicted dataset shards to S3, then kept dropping on local NVMe because the nanotron dataloader built an index that grew with the step count
  2. IL-0006 VPC subnets ran out of IP addresses because the AWS VPC CNI kept IPs on full nodes, and WARM_IP_TARGET changes then blocked pod starts after every pod deletion
    Neon2025
  3. IL-0094 Student pods filled the shared nodes of a JupyterHub cluster and starved the hub's core pods, freezing the hub
    2i2c2020
  4. IL-0064 CPU-heavy pods packed onto one Google Cloud node drove it to kernel panics, and the crash moved from node to node until the site was down
  5. IL-0075 Kubernetes API servers pegged on CPU when the cluster grew to about 290 nodes, traced to Datadog agents polling the API
  6. IL-0036 A reindex Job that kept failing exhausted one node after another until the whole cluster was down

Dependency failure1 case

Organisation
  1. IL-0025 Failed boots, InfiniBand link flapping, NCCL hangs and throughput sags while bringing up a 4,088-GPU H100 training cluster
    Imbue2024

DNS or network fault2 cases

  1. IL-0083 Intermittent 5xx errors in a multi-tenant Kubernetes cluster came from internal DNS: the node-local dnsmasq hit its 150 concurrent query limit, did not cache cluster.local answers, and ndots search lookups flooded CoreDNS
  2. IL-0056 Calls from EKS pods to services behind an NLB in another VPC failed intermittently because the AWS VPC CNI did source NAT on the node

unknown1 case

Organisation
  1. IL-0087 After a cold reboot of RKE2 nodes, pods could not get IP addresses because Multus could not reach the Kubernetes API, and further reboots spread the failure to every node

Operator error2 cases

Organisation
  1. IL-0197 Moving a three-node Elasticsearch StatefulSet to new persistent volumes split the cluster in two, because the Helm chart hardcoded cluster.initial_master_nodes to elasticsearch-0
    Palark2021
  2. IL-0054 All ingress traffic lost while draining a GKE node pool because the load balancer only targeted new nodes without ingress-nginx pods

Cloud provider outage2 cases

  1. IL-0172 An AWS Tokyo data centre cooling failure took down 6 of 60 CockroachDB nodes on Kubernetes within 22 minutes, and ranges lost quorum because the Helm-deployed cluster had no availability zone locality configured
  2. IL-0193 A GCP persistent disk degradation took down a Cassandra StatefulSet whose OrderedReady policy blocked recovery, and Metrictank could not reconnect to the recreated pods, causing a 23-hour Graphite query outage