  1. Symptoms

    After a rolling restart of the Argo CD application-controller, namespaces that several applications shared went into the Terminating state. About 97 applications were then stuck in a Missing/OutOfSync deadlock.

    Trigger

    A manual bulk sync with force: true from the Argo CD UI, run during the window after an application-controller restart, on an application whose manifests declared a namespace whose app.kubernetes.io/instance label pointed to a different application.

    Root cause
    Component
    Contributing factor
    Action items
    • Refile the problem as #29739: a manual force sync hard-replaces shared cluster-scoped resources through a tracking-ID conflict, ignoring Prune=false
    Lessons

    The sync option Prune=false only protects the prune path; it does not stop a force sync from deleting and recreating a resource. When two Argo CD applications declare the same namespace or other cluster-scoped resource, force-syncing the application that does not own the tracking label can delete it at any time.

  2. Symptoms

    GPU nodes for an AI video upscaling job were created normally and reached Ready, and then about 10 to 11 minutes later Karpenter treated each one as unhealthy and replaced it. Every new node went the same way, so the GPU pods kept restarting and the upscaling work could not make progress.

    Trigger

    Enabling Karpenter's node auto-repair feature gate (nodeRepair: true) and then running GPU pods on nodes from the Bottlerocket NVIDIA AMI.

    Root cause
    Component
    Contributing factor
    Detection

    The team noticed GPU nodes being replaced repeatedly after running GPU pods, then found the DCGMError message in the node events.

    Remediation
    • Disabled Karpenter node auto-repair by setting the nodeRepair feature gate to false
    Lessons

    Automatic node repair acts on every unhealthy node condition, including AcceleratedHardwareReady, so an image defect that only breaks GPU health monitoring is enough to have every GPU node terminated and recreated in a loop. Before turning on auto-repair, check which conditions it watches and whether the node image reports them correctly. Disabling auto-repair stops the loop at once but is only a temporary measure; installing the missing library or changing the AMI address the cause but cost more on an immutable OS such as Bottlerocket.

  3. Symptoms

    Services on Buffer's kops-managed cluster on AWS (about 60 nodes and 1500 containers) answered more slowly than they should have. The container throttling metric showed that many containers were being throttled whatever their CPU usage was, including containers that never came close to their CPU limit.

    Trigger

    CPU limits on user-facing services, enforced through CFS quota by a Linux kernel with a bug that throttled containers even when they were well under their limit.

    Root cause
    Component
    Contributing factor
    Detection

    While reviewing the container throttling metric, the team noticed many containers being throttled even though their CPU usage stayed far below their limits.

    Remediation
    • removed CPU limits from all services directly or indirectly on the users' critical path
    • moved those services to dedicated tainted nodes and gave them matching tolerations
    • set each service's CPU request to its peak usage over a few months plus a margin of more than 20%, and set memory requests the same way
    Action items
    • Move nodes to a kernel that contains the CFS throttling fix (4.19 or later), which for Buffer means a kops version whose host image is Ubuntu 20.04
    • After the kernel upgrade, check whether throttling is fully gone and update the post
    Lessons

    A CPU limit can slow a service down even when the service uses a small part of it, because of how the kernel enforces CFS quota on older kernels; the throttling metric shows it, the CPU usage graph does not. Upgrading the kernel is the safer fix. Removing limits works for latency, but only together with honest CPU and memory requests, isolation of the unbounded services, and monitoring of node usage, since unbounded containers can starve the kubelet.

  4. Symptoms

    Right after an updated RedisFailover resource was rolled out, the large Redis database lost all its data and the service went down; the data had to be restored from a backup taken just before the change.

    Trigger

    A RedisFailover change that raised the number of Redis replicas from one to two and, in the same rollout, lowered the containers' memory requests and limits from 22 GB to 19 GB.

    Root cause
    Component
    Contributing factor
    Remediation
    • restored the Redis data from the backup prepared before the rollout
    Action items
    • Report the readiness probe flaw to the Redis Operator project and test the developers' fix
    • Reconsider the use of the Spotahome Redis Operator
    • Clean up the Redis databases and fix the application code that created the excess keys
    • Consider Redis built-in clustering and sharding
    Lessons

    Changing the replica count and the pod resources in one rollout turned a seemingly harmless change into a rolling restart of the only pod with data while the new replica was still empty. A readiness probe that only checks that Redis answers a ping does not tell whether a replica has finished syncing. Operators for critical stateful components need to be evaluated for maturity before production use, and the dump.rdb file should be backed up before any change to the Redis cluster.

  5. Symptoms

    After Ravelin moved its API layer from VMs into its GKE cluster behind a Kubernetes Ingress, the integration tests occasionally received 502 errors.

    Trigger

    Pods behind the Ingress being removed by their controller, as happens during rolling deploys and scaling.

    Root cause
    Component
    Contributing factor
    Detection

    Integration tests occasionally received 502 errors.

    Lessons

    Removing a pod's endpoint and signalling the pod happen at the same time, and an ingress can take a long time to catch up. A pod behind an ingress should keep serving after SIGTERM until its grace period ends, and the grace period should be longer than the load balancer's reprogramming time.

Check your cluster for this

These 8 cases involve Ingress controller and Node operating system image. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause1

Software defect8 cases

  1. IL-0058 Argo CD deleted namespaces shared by several applications, leaving about 97 applications stuck Missing and OutOfSync
  2. IL-0171 Karpenter node auto-repair replaced EKS GPU nodes about 10 minutes after they became Ready, in a loop, because the Bottlerocket NVIDIA AMI lacked libdcgm.so and set AcceleratedHardwareReady to False
    Inflab2025
  3. IL-0029 Slow user-facing services from CPU throttling on containers that used far less CPU than their limit
    Buffer2020
  4. IL-0196 Adding a second Redis replica and lowering memory limits in one RedisFailover change restarted the only Redis pod that held data, and Sentinel promoted the empty new replica, erasing the data
    Palark2020
  5. IL-0062 Intermittent 502 errors behind a GKE Ingress because pods shut down before the load balancer stopped sending them traffic
  6. IL-0011 HAProxy ingress piled requests onto the same pods because a Go template visited the backend map in sorted pod IP order
  7. IL-0050 Pods on Kubernetes failed to resolve an external Redis hostname because of ndots:5, the musl resolver in Alpine images, and Netty's DNS resolver
  8. IL-0051 A third-party log shipping client leaked file descriptors with every new container until nodes failed with too many open files