  1. Symptoms

    While the Spring Cloud Config Server was briefly down for an upgrade, every client application began to answer its liveness probe with a failure saying it could not reach the config server.

    Trigger

    A downtime upgrade of the Spring Cloud Config Server made it stop responding for a short time.

    Root cause
    Component
    Contributing factor
    Lessons

    A liveness probe that includes an external dependency turns a short outage of that dependency into a restart loop of every client. Keep external dependencies out of liveness checks and handle temporary problems with readiness probes. Libraries can add health indicators to Spring Boot's actuator health endpoint automatically, so check what the probe path actually reports. The author ran another Kubernetes environment for two years without liveness probes, relying on strict readiness probes and on the application terminating itself on unrecoverable faults.

  2. Symptoms

    While the customer was updating the AMIs of its Amazon EKS nodes across more than 30 clusters running Istio, sidecar-injected workloads in one cluster failed to start and showed CrashLoopBackOff.

    Trigger

    Updating the EKS node AMIs, which started hundreds of sidecar-injected pods at the same time.

    Root cause
    Component
    Contributing factor
    Detection

    Sidecar-injected workloads in the updated cluster failed to start and showed CrashLoopBackOff; the customer raised a Severity 1 ticket and a Tetrate engineer was reviewing logs within six minutes.

    Remediation
    • scaled istiod down temporarily from 40 replicas to 1 to slow Istio's internal processes and ease the load on the CA
    • deleted the CertificateSigningRequests stuck in the Approved, Failed state
    • restarted the pods gradually in a controlled order instead of all at once
    Lessons

    When a mesh hands certificate signing to an external CA, every pod start becomes a signing request to that CA, so a mass restart such as a node image rollout can overload it. Sidecars then abort under istiod's 10-second default CA timeout even though the CSRs are eventually signed. Restarting pods in controlled batches keeps the request rate within what the CA can handle. The author's point is that diagnosing such a failure means looking at the whole service mesh ecosystem, including its external dependencies, not only Istio.

  3. Symptoms

    At 12:32 Prometheus on the Cloud Platform was not available after a planned change, and the Prometheus pod had restarted several times. The platform lost its monitoring and had missing metrics for the period.

    Trigger

    A planned change restarted Prometheus at a time when the WAL count was high.

    Root cause
    Component
    Contributing factor
    Detection

    The team saw that the Prometheus pod had restarted several times after the planned change.

    Remediation
    • raised the Prometheus startupProbe threshold to 30 minutes
    Action items
    • Perform planned Prometheus restarts when the WAL count is lower
    • Set the default CPU and memory requests to meet maximum usage
    • Create a test setup that recreates the live WAL count
    • Explore the memory-snapshot-on-shutdown and auto-gomaxprocs feature flags
    • Explore storing WAL files remotely in a different location
    • Look into a blue-green Prometheus to test changes on a live-like setup before applying them to live
    • Spike into Amazon Managed Prometheus
  4. Symptoms

    During a rollout of the Grafana Loki distributor Deployment in one Grafana Cloud Logs environment, the write path went down for about 25 minutes. The newly started distributor pods were OOM-killed over and over, never passed their health and readiness checks, and the rollout stopped making progress.

    Trigger

    Step 1 of moving the Loki ring off a separately deployed key-value store onto embedded memberlist added a new label, gossip_ring_member: 'true', to the distributor pods and Service, together with a small config change, and the change required a rollout of the distributors.

    Root cause
    Component
    Contributing factor
    Detection

    The first clue was kubectl get pods and the kube_deployment_status_replicas_updated metric showing that only 16 of 140 distributor pods had been updated.

    Remediation
    • scaled the distributor Deployment out horizontally so the load spread over more pods with the new label and the rollout could continue
    • reverted the migration step to end the outage
    • set service_ignored_labels:: [$._config.gossip_member_label] and passed it to k.util.serviceFor so the label is no longer copied into the Service selector
    Action items
    • Update the function that generates a Service from a Deployment or StatefulSet to handle edge cases, including this one
    Lessons

    A Service whose selector is built by copying every label of a workload changes which pods it matches as soon as a new label is added. During a rollout it then matches only the new pods, which receive all the traffic before there are enough of them. A few errors during a rollout in other environments hid the problem, because those environments gave distributors more memory and could absorb the shift. Manifest diffs kept for every pull request made it possible to see that the Service selector had changed.

  5. Symptoms

    While the old nodes of a GKE cluster were being drained to move workloads to a newly created node pool, none of the services in the cluster could be reached through ingress-nginx any more.

    Trigger

    Cordoning and draining the old node pool removed those nodes from the GCP load balancer backend while the ingress-nginx pods were still running on them.

    Root cause
    Component
    Contributing factor
    Detection

    The team noticed during the drain that no service in the cluster was reachable through ingress-nginx.

    Remediation
    • deleted the nginx-ingress-controller pods still running on the old nodes so they were rescheduled on the new, ready nodes
    Lessons

    With externalTrafficPolicy: Local, the load balancer can only reach nodes that run an ingress pod, and cordoned nodes leave the load balancer backend immediately; if the ingress pods stay behind on cordoned nodes, all ingress traffic stops. Before any change that might touch traffic, look twice into the documentation.

Check your cluster for this

These 6 cases involve Admission webhook and Configuration templating. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause5

Dependency failure2 cases

  1. IL-0187 A brief Spring Cloud Config Server downtime failed every client application's liveness probe, because the actuator health check included the config server, and Kubernetes restarted the pods in a kill loop
  2. IL-0103 During an EKS node AMI update, Istio sidecars crash-looped because hundreds of pods restarting at once overloaded the external certificate authority behind istiod

Capacity exhaustion1 case

Component
  1. IL-0046 Prometheus restarted again and again because its WAL replay took longer than the startup probe allowed

Configuration change1 case

Organisation
  1. IL-0191 A label selector accidentally added to the Loki distributor Service matched only the new pods of a rollout, which took all write traffic, were OOM-killed and stalled the rollout

Operator error1 case

Organisation
  1. IL-0054 All ingress traffic lost while draining a GKE node pool because the load balancer only targeted new nodes without ingress-nginx pods

unknown1 case

Organisation
  1. IL-0059 Single-master Kubernetes control plane kept dying because the kubelet restarted a healthy etcd on a failing kubeadm liveness probe