  1. Symptoms

    From 10:03 UTC on 29 September 2026, requests to Azure OpenAI Service, Foundry Agent Service, Foundry Models and Azure AI services in Sweden Central failed intermittently, took longer, or returned HTTP 500 and 503 errors. At 10:17 UTC service monitoring raised an alert on elevated failure rates for Azure OpenAI Service requests in the region.

    Trigger

    At about 09:38 UTC a planned deployment of an internal service in Sweden Central cleared that service's caches during the region's peak traffic hours.

    Root cause
    Component
    Contributing factor
    Detection

    Service monitoring detected elevated failure rates for Azure OpenAI Service requests in the region at 10:17 UTC and alerted the engineering teams; engineers were engaged at 10:28 UTC.

    Remediation
    • reconfigured the backend service's automated health check so it no longer depended on remote connectivity, which stopped the restart loop
    Action items
    • Reconfigure the backend service's automated health check so it no longer depends on connectivity to its database layer
    • Add monitoring and alerting on the load and latency of the caching layer used by the backend service
    • Update troubleshooting and procedural guidance for connection exhaustion scenarios for on-call engineers
    • Add throttling and rate limiting to protect the backend service from sudden traffic increases (estimated October 2026)
    • Increase the resource capacity of the caching layer used by the backend service across regions (estimated October 2026)
    • Improve diagnostic metrics and automated detection to identify such issues more quickly (estimated October 2026)
    • Partition the caching layer used by the backend service to increase its throughput (estimated December 2026)
    Lessons

    A health check that depends on a remote dependency turns a dependency problem into a restart loop: instances that cannot reach the database are killed, the remaining ones take more load and retries, and adding instances or resources does not help until the check itself is changed. Clearing a cache during peak traffic can multiply load on the backend behind it, especially when cache-read defects let lookups bypass the cache. Connection exhaustion was hard to see because the existing network and diagnostic metrics did not show it.

  2. Symptoms

    The day began with an alert that several instances of the Redis cluster were running out of disk space. That part was fixed quickly. The outage came an hour later: right after the Redis StatefulSet was deleted and recreated at 8:10 UTC, Kubernetes restarted every Redis pod within about five minutes, and problems started to appear.

    Trigger

    To make Git match the volumes that had been resized by hand, the Redis StatefulSet was deleted with orphan (non-cascading) deletion and recreated with the new storage template; Kubernetes reconciled the new spec by restarting the entire Redis cluster.

    Root cause
    Component
    Contributing factor
    Detection

    An alert about Redis instances running out of disk space started the work; the outage itself showed up as backend errors about Redis connections right after the StatefulSet was recreated.

    Remediation
    • made the Redis masters forget obsolete node identities, reset the affected replicas and rejoined them, then waited for replication to catch up
    • identified the component that was actually running out of memory, scaled the backend service and raised memory limits for that component
    • temporarily relaxed probes so backend instances took traffic immediately instead of flapping between ready and not ready
    • reverted the temporary workarounds at 10:00 UTC
    Action items
    • Add startup probes so a Redis pod is not marked ready until its dataset is loaded
    • Build an own control plane for Redis that handles restarted pods stuck to an old master address
    • Reduce dependence on the single Redis cluster: move some important data to other stores, such as a separate Redis cluster per server, and use Kafka for some backend components
    Lessons

    The disk resize was not the problem; the cleanup afterwards was. An immutable field pushes operators toward deleting and recreating the controller, and that can set off a full reconcile. Startup and readiness probes are what slow a rolling restart down to a safe pace; without them a distributed store restarts in the most fragile way. Recovery plans must expect a cluster to heal slowly, and dependent services need to degrade gracefully while it does.

  3. Symptoms

    While the Spring Cloud Config Server was briefly down for an upgrade, every client application began to answer its liveness probe with a failure saying it could not reach the config server.

    Trigger

    A downtime upgrade of the Spring Cloud Config Server made it stop responding for a short time.

    Root cause
    Component
    Contributing factor
    Lessons

    A liveness probe that includes an external dependency turns a short outage of that dependency into a restart loop of every client. Keep external dependencies out of liveness checks and handle temporary problems with readiness probes. Libraries can add health indicators to Spring Boot's actuator health endpoint automatically, so check what the probe path actually reports. The author ran another Kubernetes environment for two years without liveness probes, relying on strict readiness probes and on the application terminating itself on unrecoverable faults.

  4. Symptoms

    While the customer was updating the AMIs of its Amazon EKS nodes across more than 30 clusters running Istio, sidecar-injected workloads in one cluster failed to start and showed CrashLoopBackOff.

    Trigger

    Updating the EKS node AMIs, which started hundreds of sidecar-injected pods at the same time.

    Root cause
    Component
    Contributing factor
    Detection

    Sidecar-injected workloads in the updated cluster failed to start and showed CrashLoopBackOff; the customer raised a Severity 1 ticket and a Tetrate engineer was reviewing logs within six minutes.

    Remediation
    • scaled istiod down temporarily from 40 replicas to 1 to slow Istio's internal processes and ease the load on the CA
    • deleted the CertificateSigningRequests stuck in the Approved, Failed state
    • restarted the pods gradually in a controlled order instead of all at once
    Lessons

    When a mesh hands certificate signing to an external CA, every pod start becomes a signing request to that CA, so a mass restart such as a node image rollout can overload it. Sidecars then abort under istiod's 10-second default CA timeout even though the CSRs are eventually signed. Restarting pods in controlled batches keeps the request rate within what the CA can handle. The author's point is that diagnosing such a failure means looking at the whole service mesh ecosystem, including its external dependencies, not only Istio.

  5. Symptoms

    From 3:30am to 7:08am PT, chatgpt.com and a small number of OpenAI APIs returned elevated error rates. The status page classed the incident as a full outage.

    Trigger

    A failure of Cosmos DB in ChatGPT, at OpenAI's service provider.

    Root cause
    Component
    Contributing factor
    Remediation
    • the service provider recovered the affected Cosmos DB databases at 4:25am PT
    • fixed the web server's health checking logic, which ended the pod crash loop
    Action items
    • Change the web systems to degrade more gracefully when they fail, including concurrency control and better load shedding
    • Make the database layer more resilient to service provider outages (described as already underway)
    Lessons

    The database came back at 4:25am PT, yet users saw errors until 7:08am PT: the web tier's own health checks kept removing pods after the dependency had recovered. The planned changes target the web tier's behaviour under failure, with concurrency control and load shedding, rather than the database alone.

Check your cluster for this

These 16 cases involve Container memory limit and Prometheus. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause8

Faulty deployment2 cases

  1. IL-0136 A deployment that cleared an internal service's caches at peak traffic sent 20 times the normal load to the Azure OpenAI metadata backend in Sweden Central, and health checks that depended on its database restarted instances in a loop for almost six hours
  2. IL-0034 A crashing stats agent sidecar marked every pod unready and the service mesh pulled all services out of traffic
    Airbnb2019

Configuration change2 cases

  1. IL-0063 VPN outage after recreating a Redis StatefulSet restarted the whole Redis cluster without readiness checks
  2. IL-0191 A label selector accidentally added to the Loki distributor Service matched only the new pods of a rollout, which took all write traffic, were OOM-killed and stalled the rollout

Dependency failure2 cases

  1. IL-0187 A brief Spring Cloud Config Server downtime failed every client application's liveness probe, because the actuator health check included the config server, and Kubernetes restarted the pods in a kill loop
  2. IL-0103 During an EKS node AMI update, Istio sidecars crash-looped because hundreds of pods restarting at once overloaded the external certificate authority behind istiod

Cloud provider outage1 case

Organisation
  1. IL-0119 ChatGPT web service pods crash-looped on failing health checks after a Cosmos DB failure, leaving too few healthy pods to serve the web layer
    OpenAI2025

Capacity exhaustion3 cases

  1. IL-0044 Prometheus OOMKilled in a loop while replaying its write-ahead log after a kube-prometheus-stack upgrade
  2. IL-0046 Prometheus restarted again and again because its WAL replay took longer than the startup probe allowed
  3. IL-0176 Prometheus in a 235-node Kubernetes cluster crash-looped because over two million series exhausted host memory and the kernel OOM killer chose it first, as Burstable QoS gave it oom_score_adj 999
    LINE2020

Software defect3 cases

Organisation
  1. IL-0123 A response buffer allocated anew in a loop made OpenAI's routing layer nodes hit their memory limits and fail readiness checks on a morning with more completions than any day before, causing 502 and 503 errors across all models
    OpenAI2023
  2. IL-0106 A malformed Traefik IngressRoute triggered a Traefik v2 bug once a node rollover restarted every Traefik pod, and all Kubernetes services returned 404
    DFDS2021
  3. IL-0012 CPU limits and an unpatched kernel CFS quota bug throttled multi-threaded services into stalls, failed health checks and timeouts
    Omio2020

unknown2 cases

  1. IL-0045 Prometheus on the live cluster restarted several times after readiness probe failures, leaving gaps in metrics
  2. IL-0059 Single-master Kubernetes control plane kept dying because the kubelet restarted a healthy etcd on a failing kubeadm liveness probe

Operator error1 case

Organisation