  1. Symptoms

    In Amazon's large-scale foundation model training, training steps took about 0.3 seconds longer (8.7 s instead of 8.4 s) when a node had a GPU whose network adapter had failed. No hardware failure alert fired, and standard node checks such as GPU burn-in and short NCCL tests rarely catch such nodes.

    Trigger

    The network adapter of one GPU on a node failed.

    Root cause
    Component
    Contributing factor
    Detection

    No hardware alert or standard health check showed the fault. It showed as slower training steps, in the per-node network device status and transmission rate that Guard monitors, and as elevated latency or reduced bandwidth in a 2-node sweep.

    Remediation
    • Resolved the degraded communication path, which brought training step time from 8.7 s back to 8.4 s
    Action items
    • Monitor each node's network device status continuously to find and isolate nodes whose traffic NCCL rerouted
    • Remove a node flagged by online monitoring from the healthy node pool and schedule it for offline verification
    • Run a multi-node sweep that stresses cross-node collective communication to expose degraded links and misrouted traffic
    • Trigger node sweeps after anomalies found by online monitoring and after repairs, before a node re-enters production
    Lessons

    NCCL's transparent rerouting keeps both the job and NCCL tests working while it hides a failed adapter, so checks that verify functional correctness do not find the node. Amazon relies on performance-aware monitoring during training, with step time as the main signal, and on offline verification under realistic load before nodes return to service.

  2. Symptoms

    In the week of 10 October 2022, Linode Object Storage in Newark had two incidents of reduced performance and availability, on 10 and 16 October, and in some cases the front-end gateways returned 504 gateway timeouts to customers. The second incident began while the first was still being investigated.

    Trigger

    One back-end Object Storage node had a hardware problem that was not an outright failure, so the node kept going up and down.

    Root cause
    Component
    Contributing factor
    Remediation
    • Removed the failed back-end infrastructure from the Object Storage cluster
    Action items
    • Improve detection so subtle problems with failing or misbehaving hardware are found and triaged before they affect the wider cluster
    • Describe Ceph-related events more accurately to on-call administrators and define alerts more clearly
    Lessons

    Hardware that misbehaves without failing outright can cause service-wide problems, and Linode's internal monitoring had gaps in spotting such subtle issues before they affected the wider cluster.

Check your cluster for this

These 2 cases involve NCCL and NIC, cable and switch port link. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause1