Incident Library
  • Root cause
  • Component
  • Symptom
  • Contributing factor
  • Case

Cases4 cases

1 to 4 of 4

  1. Symptoms

    The day began with an alert that several instances of the Redis cluster were running out of disk space. That part was fixed quickly. The outage came an hour later: right after the Redis StatefulSet was deleted and recreated at 8:10 UTC, Kubernetes restarted every Redis pod within about five minutes, and problems started to appear.

    Trigger

    To make Git match the volumes that had been resized by hand, the Redis StatefulSet was deleted with orphan (non-cascading) deletion and recreated with the new storage template; Kubernetes reconciled the new spec by restarting the entire Redis cluster.

    Root cause
    Component
    Contributing factor
    Detection

    An alert about Redis instances running out of disk space started the work; the outage itself showed up as backend errors about Redis connections right after the StatefulSet was recreated.

    Remediation
    • made the Redis masters forget obsolete node identities, reset the affected replicas and rejoined them, then waited for replication to catch up
    • identified the component that was actually running out of memory, scaled the backend service and raised memory limits for that component
    • temporarily relaxed probes so backend instances took traffic immediately instead of flapping between ready and not ready
    • reverted the temporary workarounds at 10:00 UTC
    Action items
    • Add startup probes so a Redis pod is not marked ready until its dataset is loaded
    • Build an own control plane for Redis that handles restarted pods stuck to an old master address
    • Reduce dependence on the single Redis cluster: move some important data to other stores, such as a separate Redis cluster per server, and use Kafka for some backend components
    Lessons

    The disk resize was not the problem; the cleanup afterwards was. An immutable field pushes operators toward deleting and recreating the controller, and that can set off a full reconcile. Startup and readiness probes are what slow a rolling restart down to a safe pace; without them a distributed store restarts in the most fragile way. Recovery plans must expect a cluster to heal slowly, and dependent services need to degrade gracefully while it does.

  2. Symptoms

    On 2022-10-31 a planned upgrade of the vpc-cni EKS add-on, started from the deployment pipeline at 13:45 UTC, timed out at 14:10. Only about 10 of the 45 aws-node pods had upgraded, 5 were stuck in Terminating and the other 30 had not been attempted.

    Trigger

    At 07:30 UTC on 2022-10-31 the daily node rollover replaced the existing nodes with nodes built from AMI v20221027, the latest AWS EKS node AMI, released on 2022-10-29 and later recalled because of a kernel issue.

    Root cause
    Component
    Contributing factor
    Detection

    The team noticed nodes flapping between NodeNotReady and NodeReady ("KubeletNotReady PLEG is not healthy") at 14:30 UTC while watching the stalled vpc-cni upgrade, about seven hours after the rollover. Time to detection was 7 hours. Alerting did not catch the NodeNotReady events or the socket growth.

    Remediation
    • cordoned, drained and deleted 15 stuck nodes one at a time to complete the vpc-cni upgrade
    • changed the Terraform infrastructure-modules so a specific AMI could be set
    • rolled the EC2 Auto Scaling group launch configuration back to the previous known good AMI through the pipeline
    Action items
    • Reach out to teams with suggestions about readiness and liveness probes
    • Create a dashboard for readiness and liveness probe coverage
    • Write a wiki article on readiness and liveness probes and their usefulness
    • Modify infrastructure-modules to allow specifying a particular AMI
    • Schedule a discussion on whether to take the latest AMI immediately and how to test new AMIs before they are deployed
    • Implement alerting on abnormal NodeNotReady events and on increased socket use
    • Create a learning path for Kubernetes within the team
    • Collect logs from nodes centrally
    • Create a Prometheus exporter that retrieves the latest available AMI, with a dashboard and alerts
    Lessons

    When a new node AMI has just been rolled out, upgrading other cluster components on the same day makes it hard to tell which change is causing trouble; here the vpc-cni upgrade on the same day confused matters. Taking the latest AMI automatically with no way to pin one meant a rollback first needed a Terraform change. The team also concluded that it needs better communication paths with application teams during incidents.

  3. Symptoms

    Jetstack was upgrading the master of a development cluster that many teams use to test their apps during the working day, a regional Google Kubernetes Engine (GKE) cluster in europe-west1. The upgrade ran through Jetstack's GKE Terraform pipeline and did not finish before the 20-minute Terraform timeout, while the GKE console still showed the cluster as upgrading.

    Trigger

    A planned master upgrade of the shared development cluster. The same upgrade had been done on another pre-production environment earlier that day, and no API downtime was expected.

    Root cause
    Component
    Contributing factor
    Detection

    The first sign was the master upgrade missing the 20-minute Terraform timeout; re-running the pipeline returned the kube-apiserver unhealthy error. The cause was identified with the help of Google Support.

    Remediation
    • Deleted the OPA ValidatingAdmissionWebhook resource during a window of API server access
    Action items
    • Limit the OPA webhook to the namespaces where the policy applies and development teams have access
    • Enable the webhook only for Ingress and Service resources, the only resources the policy validates
    • Add a liveness probe so OPA is restarted when it stops responding, and update the OPA documentation
    • Follow the open upstream Kubernetes issue about this behaviour
    Lessons

    With alerting on API server response times, the team might have seen CREATE and UPDATE requests slow down across the board as soon as the OPA-backed webhook was first deployed. Every workload needs probes: OPA looked so simple to deploy that the team skipped the Helm chart, which adds a livenessProbe for the admission controller containers among other adjustments to the tutorial configuration. Others had hit the same problem, and an upstream issue to improve it was still open.

  4. Symptoms

    During a rolling update of a kubelet change in one of Oath's on-premises production clusters, nodes started going NotReady, and soon all nodes in the cluster were NotReady.

    Trigger

    A change to kubelet was rolled out across the nodes of one cluster; on restart, kubelet cleans up transient cgroup files, and a Kubernetes bug in that step left kubelet stuck instead of starting.

    Root cause
    Component
    Contributing factor
    Detection

    Nodes reported NotReady and the eviction graphs climbed while the kubelet rollout was in progress.

    Remediation
    • failed the affected data center over so users were routed to the next available data center
    Action items
    • Run a functional test of kubelet after each upgrade batch and certify it before the next 30% of nodes are updated
    Lessons

    Check kubelet after upgrading it before moving to the next batch; a simple curl against the kubelet API would have caught this. The node controller's eviction throttling and full disruption mode, which the speakers note is not well documented, kept a cluster-wide kubelet failure from evicting every pod.

Check your cluster for this

These 4 cases involve kubelet and Admission webhook. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.