IL-0400Public sector sites across Wales lost connectivity for over 8 hours as a PE router wrongly advertised a default routePSBA2026- Symptoms
On 25 March 2026 from about 16:40, public sector organisations on the PSBA network across Wales lost connectivity at their sites. The Service Desk saw about 400 alerts at 16:58, when a Major Incident was declared, about 1,500 at 17:05 and about 5,000 across Wales at 17:08, while councils, a fire and rescue service and Natural Resources Wales phoned in to report sites down.
- Trigger
At 16:30 a route map change was applied, outside formal change control, on a PSBA core Provider Edge (PE) router to leak MPLS VPN routes, so that legacy Capita-operated UPS devices in a /16 subnet could be managed by BT/PSBA. The change was removed at 16:40.
- Root cause
- Component
- Contributing factor
- Detection
At 16:57 Mid Wales Fire & Rescue Service phoned in a loss of connectivity at its Presteigne site, and at 16:58 a case was opened in Service Now for a group of about 400 alerts and a Major Incident was declared.
- Remediation
- Removed the route map change from the PE router at 16:40
- Changed QoS on the BGP to bring back the management links, after which alarms cleared
- Cleared routes and reset inbound BGP advertisements, which did not stop the default route being advertised
- Corrected the configuration issue affecting the internet learned route at 01:02
- Performed a controlled reload of the affected router at 01:10, which restored customer services and management connectivity
- Action items
- Reinforce change control requirements with an internal briefing on formal change submission, the risks of unplanned changes and roles during planned and emergency changes
- Create a dedicated Microsoft Teams channel as the single real-time communication point for all live P1 and Major Incidents
- Explore disaster recovery and business continuity test exercises for major or P1 incidents
- During loss of management access, have all technical teams assess customer impact from what reporting organisations provide, captured and shared in real time by the Service Desk and Incident Management
- Investigate a fixed link between Capital Quarter and the PSBA management racks in Vantage Data Centre at Newport, with dedicated management terminals and two-factor authentication for access outside the secure management platform
- Improve initial triage with stronger probing questions when incidents are reported and keep reassessing and communicating impact throughout the incident
- Review the P1 and Major Incident process so escalation criteria and timeframes are clearly defined, and train the Service Desk to recognise and escalate them early
- Review the PSBA estate for legacy configuration, set processes and timeframes for removing it and add controls so it is not introduced again
- Review email and SMS distribution lists and processes and reinforce Service Desk training on customer communications during P1 and Major Incidents
- Lessons
The report names eight lessons: a change was made outside PSBA change control; internal communication during the Major Incident was slow and fragmented; the organisation was not ready for a network-wide incident; losing management access stopped the resolver groups from seeing the network state and customer impact; the resolver groups did not understand customer impact in enough detail, which delayed finding the root cause; escalation to PSBA management was slow; legacy configuration left in the network contributed; and email and SMS communications did not reach some customers in time.
- Symptoms
On 23 November 2021 at 09:39, two minutes after a change on the eqiad core routers, alerts fired because Icinga in eqiad could not reach the public text-lb address in eqsin (Singapore). For about 12 minutes eqiad could not reach hosts in other data centers, such as the cache PoPs, through their public IP addresses.
- Trigger
At about 09:37 a change on cr1-eqiad and cr2-eqiad, made as part of task T295672 to influence BGP route selection, removed a BGP setting that sets the BGP "MED" attribute to the OSPF cost of reaching the BGP route's next hop.
- Root cause
- Component
- Contributing factor
- Detection
Icinga health checks against edge caching clusters alerted at 09:39; the first alert was Icinga in eqiad failing to reach the public text-lb address in eqsin.
- Remediation
- Reverted the configuration change on both eqiad routers
- Forced a reset of the BGP session between the two eqiad routers
- Action items
- Updated T295672 with further detail on the incident and a proposal to adjust the BGP sessions to address the "second IXP port" issue and prevent this from happening again
IL-0228IPv4 routing across OVHcloud's global network broke after a router change put the full internet routing table into OSPFOVHcloud2021- Symptoms
At 09:20 CET on 13 October 2021, during a planned change on a router, IPv4 traffic across OVHcloud's whole network stopped being routed, while all IPv6 traffic stayed reachable. The team detected a problem with the router's performance at 09:21 CET and escalated at once.
- Trigger
A planned change to a router in the Vint Hill datacentre in the United States, meant to strengthen anti-DDoS protection, included a command to regulate the redistribution of BGP into OSPF, and the router did not interpret that command correctly.
- Root cause
- Component
- Contributing factor
- Detection
At 09:21 CET the team detected a problem with the router's performance and started the escalation process.
- Remediation
- Disconnected the optical equipment to isolate the router's connectivity
- Powered off the faulty router
- Stabilised connectivity to restore the remaining services
- Action items
- Re-evaluate the change procedure for this type of equipment, which applies the command line natively
- Strengthen the related change process
These 3 cases involve BGP routing and Backbone network (WAN). kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.
By root cause1
Configuration change3 cases
- Contributing factor
- Organisation
IL-0400Public sector sites across Wales lost connectivity for over 8 hours as a PE router wrongly advertised a default routePSBA2026IL-0266Eqiad routers looped traffic between each other after a BGP MED change and could not reach other sites' public IPsIL-0228IPv4 routing across OVHcloud's global network broke after a router change put the full internet routing table into OSPFOVHcloud2021