Incident Library
Applied filters FactorAutomation amplificationDomainKubernetesClear allEvery case under the filters, with no sentence; newest first.
Suggested filters Search, and the values found in your words appear here.

Graph

  • Root cause
  • Component
  • Symptom
  • Contributing factor
  • Case

Cases30 cases

6 to 10 of 30

  1. Symptoms

    Creating or scaling a node pool on AKS 1.31.8 failed: the VMSS instances never finished provisioning. This started after planned maintenance moved the node image from 202507.* to 202508.*, in a cluster where nodes must send all outbound traffic through an internal HTTP/HTTPS proxy and direct egress is blocked. It happened with both Ubuntu and AzureLinux images.

    Trigger

    A node image auto-upgrade from 202507.* to 202508.* during planned maintenance, on clusters whose Kubernetes patch version was not pre-cached in the new image.

    Root cause
    Component
    Contributing factor
    Detection

    The customer saw VMSS instance provisioning fail with a vmssCSE error in the VMSS activity logs and reported it as a GitHub issue.

    Remediation
    • The customer pinned the node image to a 202507.* snapshot on clusters running 1.31.8
    • The customer upgraded clusters to AKS 1.31.9 or 1.31.10, whose binaries are cached in the 202508.* images
    • The AKS team hot-patched VHD 20250811 so the proxy configuration is used for uncached binary downloads and made it globally available in public regions on 2025-09-04; it also announced the hotfix for VHD 20250820
    • The AKS team told users to reimage their nodes with az aks nodepool upgrade --node-image-only to pick up the hotfixed image
    Action items
    • Apply the proxy fix in all future VHDs
    Lessons

    A bootstrap path that runs only when an artefact is missing from a cache is easy to break without noticing: here only clusters on Kubernetes versions not pre-cached in the node image ever downloaded binaries, so only they met the proxy regression. Testing node provisioning behind a mandatory egress proxy, on older patch versions as well as the newest, would exercise that path. For clusters with restricted egress, pinning the node image or moving to a Kubernetes version cached in the image were both quick workarounds while the fix was shipped.

  2. Symptoms

    On 18 October 2024, from 7:50 to 8:01 UTC, about 25% of the hypervisors in Scaleway's FR-PAR-1 availability zone lost VPC connectivity with the rest of the region, and products that use VPC failed with them. Public internet connectivity and Elastic Metal VPC connectivity were not affected.

    Trigger

    At 6:20 UTC a Top of Rack switch in FR-PAR-1 had a software crash. One of the two BGP route reflectors for VPC ran on a hypervisor in that rack and was left in an abnormal state.

    Root cause
    Component
    Contributing factor
    Detection

    Health-check monitoring on both route reflectors detected the anomaly, and the Scaleway Customer Excellence and SRE teams detected the customer impact and opened an incident.

    Remediation
    • Fixed both VPC route reflectors by manual action
    Action items
    • Fixed the autohealing mechanism that had failed to fix route reflectors stuck in a stale state; the fix is https://github.com/FRRouting/frr/pull/17163
    • Run different software versions on the route reflectors so a single bug cannot stop several instances
    • Investigate the software issue that left the route reflectors in a stale state
  3. Symptoms

    Between 14:20 and 15:16 UTC on 27 August 2024, some HubSpot customers could not log in to their accounts, reach their content or use HubSpot tools. Requests were slow or failed because HubSpot's internal load balancers, which run on Kubernetes and spread traffic across the backend services, were overloaded.

    Trigger

    Routine operation of a critical component of HubSpot's traffic management system, from about 14:08 UTC, ran path handling updates in the load balancer stack, and an issue in that stack made those updates block health check responses.

    Root cause
    Component
    Contributing factor
    Detection

    Monitoring detected widespread performance degradation across the platform at 14:23 UTC and the incident response team was mobilised. HubSpot says it had identified the issue internally by 14:20 UTC. The status page was not updated until 14:44 UTC, which left customers with outdated information.

    Remediation
    • Tried to increase the capacity of the remaining load balancer instances
    • Brought new load balancer instances online, which relieved the pressure and let traffic return to normal
    Action items
    • Change the health check configuration so health checks do not time out falsely
    • Redesign the health check system so health checks get priority and keep running during operations such as configuration updates
    • Increase the capacity of the load balancers for sudden traffic spikes
    • Change the load balancing architecture to detect traffic surges earlier and distribute load dynamically in real time
    • Update the status page automatically for large-scale outages
    • Integrate the monitoring systems more tightly with the communication tools
    • Expand load testing to simulate high-traffic scenarios
    • Introduce chaos engineering to test platform resilience regularly
    • Add traffic pattern metrics, including the ratio of current connections to the maximum allowed
    • Add auto-scaling that adjusts resource capacity to traffic patterns
    Lessons

    HubSpot concluded that earlier detection of the abnormal traffic surge could have prevented the cascading failure, and that health checks have to keep running during operations such as configuration updates so that working load balancers are not removed together. The late status page update caused confusion for customers.

  4. Symptoms

    When traffic changed sharply, CoreDNS came under heavy load, and the cluster saw network problems and a sudden rise in latency. The horizontal pod autoscaler then added pods, database connections surged, and the impact spread to the whole service.

    Trigger

    Sharp changes in traffic loaded the small number of CoreDNS pods beyond what they could handle.

    Root cause
    Component
    Contributing factor
    Remediation
    • Set up the Cluster Proportional Autoscaler for CoreDNS with nodesPerReplica and coresPerReplica chosen for the instance types in use
    • Spread CoreDNS with soft topologySpreadConstraints (ScheduleAnyway) instead of anti-affinity so Karpenter could consolidate nodes
    • Added alert thresholds on CoreDNS error rate, panics, request duration and request rate
    • Deployed NodeLocal DNSCache so each node answers DNS from a local cache and forwards misses to the main CoreDNS
    Lessons

    A fixed, small number of CoreDNS pods cannot follow a cluster whose nodes and pods change quickly with traffic, and the damage spreads: DNS latency triggers autoscaling, which in turn floods the database with connections. Simply adding many CoreDNS replicas created a different problem, because with tainted nodes and a maxSkew: 1 spread constraint the pods piled onto a few nodes and blocked Karpenter consolidation. Scaling CoreDNS in proportion to the cluster and putting a DNS cache on every node handled both.

  5. Symptoms

    From 08:00 US/Pacific on 12 March 2024, GKE GPU nodes running Container-Optimized OS (COS) that were newly created or recreated came up with GPU drivers that did not work, so workloads that used the GPUs could not run. GKE showed elevated errors.

    Root cause
    Component
    Contributing factor
    Detection

    The report does not say how Google detected the issue. Affected users saw "Failed to download GPU driver installer, status: 403 Forbidden" on the GPU node when installing the driver.

    Remediation
    • Halted automatic node recreations, which attempt GPU driver downloads, until the issue was mitigated
    • Worked with the driver partner to resolve access to the driver download bucket
    Lessons

    The status page report states no lessons or follow-up actions.

Check your cluster for this

These 30 cases involve Database and Node operating system image. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause8

Capacity exhaustion8 cases

  1. IL-0102 CoreDNS pods on a production EKS cluster ran out of memory under a burst of new pods, endpoints and nodes, taking down the Buildkite web UI, APIs and job dispatch
  2. IL-0350 Hosts in an IONOS TXL cluster lost connectivity when an InfiniBand fabric resweep failed on a full multicast table
  3. IL-0182 Too few CoreDNS replicas on EKS were overloaded during traffic spikes, raising latency and cutting the network for task pods, and the over-provisioned, tightly spread CoreDNS pods added later blocked Karpenter consolidation
  4. IL-0168 Simultaneous cluster auto-upgrades overloaded Scaleway's Kubernetes API, and a node authentication retry loop kept Kapsule and Kosmos nodes NotReady in FR-PAR
  5. IL-0202 A burst of queries and database writes exhausted connection pools and memory on Honeycomb's ingest hosts, and Kubernetes crash-loop back-off kept failed hosts offline so ingest capacity stayed too low to recover
  6. IL-0037 Image registry rate-limited a whole region after a crash-looping DaemonSet with imagePullPolicy Always pulled through three NAT instances
  7. IL-0064 CPU-heavy pods packed onto one Google Cloud node drove it to kernel panics, and the crash moved from node to node until the site was down
  8. IL-0036 A reindex Job that kept failing exhausted one node after another until the whole cluster was down

Software defect6 cases

  1. IL-0150 A latent race condition in DynamoDB's DNS automation left an empty DNS record for dynamodb.us-east-1.amazonaws.com, and the DynamoDB and EC2 launch failures that followed caused EKS, ECS and Fargate container launch failures and cluster scaling delays in us-east-1
  2. IL-0171 Karpenter node auto-repair replaced EKS GPU nodes about 10 minutes after they became Ready, in a loop, because the Bottlerocket NVIDIA AMI lacked libdcgm.so and set AcceleratedHardwareReady to False
    Inflab2025
  3. IL-0147 AKS nodes behind an HTTP proxy failed to provision with CSE exit code 31 on 202508 node images, because a refactoring stopped the proxy from being used when downloading uncached Kubernetes binaries
  4. IL-0347 About 25% of Scaleway FR-PAR-1 hypervisors lost VPC connectivity when both VPC BGP route reflectors got stuck
  5. IL-0495 HubSpot's internal load balancers on Kubernetes were falsely marked unhealthy and the rest collapsed under the traffic
  6. IL-0112 The daily node rollover put DFDS's EKS nodes on an AMI later recalled for a kernel issue, causing "PLEG is not healthy" NodeNotReady flaps and pod network timeouts
    DFDS2022

Dependency failure3 cases

  1. IL-0187 A brief Spring Cloud Config Server downtime failed every client application's liveness probe, because the actuator health check included the config server, and Kubernetes restarted the pods in a kill loop
  2. IL-0021 GKE GPU nodes on Container-Optimized OS could not download NVIDIA drivers (403 Forbidden) and came up without working GPUs
  3. IL-0073 Intermittent Kafka connectivity overloaded Docker daemons, set off a node rescheduling cascade and poisoned the Consul gossip mesh
    Target2019

Configuration change8 cases

  1. IL-0152 An incorrect configuration applied during maintenance made an internal infrastructure cluster automatically delete the control planes of 200 DOKS clusters in FRA1
  2. IL-0109 A retried node rollover on a DFDS EKS cluster set the Auto Scaling group back to 15 instances, and the default termination policy removed every healthy worker node, leaving the cluster with no nodes
    DFDS2023
  3. IL-0009 A duplicated generated name made Argo CD replace the InfluxDB Cloud production Application and delete the whole production environment
  4. IL-0208 A GitLab chart bump that renamed Kubernetes Service and Deployment ports made the GCP load balancer reconfigure, and GitLab.com slowed down and returned intermittent 50x errors
    GitLab2022
  5. IL-0010 A templating change that dropped its {{ }} delimiters made Argo CD delete all 478 Skyscanner services in every region
  6. IL-0008 An unresponsive OPA validating webhook crash-looped the API server during a GKE master upgrade, and node auto-repair then recreated every node
  7. IL-0004 A new default pod priority let a new Cortex cluster preempt every production ingester in a cascade, taking Grafana Cloud Hosted Prometheus down
  8. IL-0055 A failing CronJob with the default concurrency policy piled up thousands of restarting pods and took down a cluster
    Target2018

Faulty deployment1 case

Organisation
  1. IL-0437 Old pods from an unfinished Argo Rollouts canary could not start with a Helm-updated ConfigMap and died in a cascade
    Gunosy2023

Breaking change in an upgrade2 cases

  1. IL-0198 An automatic Ubuntu security update restarted systemd-networkd, which flushed the IP rules Cilium relied on and cut more than 60 percent of Datadog's Kubernetes nodes off the network across regions and cloud providers
  2. IL-0144 A systemd security update installed by unattended-upgrades lost the DNS configuration of Ubuntu 18.04 VMs, so AKS kubelets could not resolve registry names and pods failed with ImagePullBackOff

Cloud provider outage1 case

Contributing factor
  1. IL-0514 PyPI's backends stopped responding for 7 minutes as rescheduled pods could not start while Consul and Vault were down

DNS or network fault1 case

Organisation
  1. IL-0049 Partial DNS outage after CoreDNS scaled down and kube-proxy failed to delete stale conntrack entries
    Preply2020