  1. Symptoms

    After an upgrade of the kube-prometheus-stack Helm chart, several pods stayed not ready. Among them was prometheus-prometheus-operator-prometheus-0, showing 3/4 Running and a recent termination.

    Trigger

    During the kube-prometheus-stack Helm chart upgrade, Prometheus had to replay its write-ahead log on startup, and the replay needed more memory than its limit allowed.

    Root cause
    Component
    Contributing factor
    Detection

    The team noticed pods not ready after the Helm chart upgrade and found the OOMKilled termination with kubectl describe pod.

    Remediation
    • ran promtool tsdb analyze inside the Prometheus pod to find high-cardinality metrics such as haproxy_server_http_responses_total
    Action items
    • Verify that the memory overhead during WAL replay stays within acceptable limits, for example 10 to 15%, and do not run Prometheus close to its memory limit
    • Optimise storage, scraping and remote write configuration and upgrade to newer Prometheus releases
    • Recover automatically from OOM crash loops, for example by deleting the WAL on OOM events
    • Enforce scrape limits so Prometheus stops scraping targets when memory use passes a threshold
    Lessons

    Size Prometheus for its restart, not only for steady state: WAL replay can need far more memory than normal running, and a Prometheus that already runs near its limit can be OOM-killed during the replay. Much of Prometheus memory use comes from cardinality, which promtool tsdb analyze can measure even when Prometheus itself is down.

  2. Symptoms

    At 12:32 Prometheus on the Cloud Platform was not available after a planned change, and the Prometheus pod had restarted several times. The platform lost its monitoring and had missing metrics for the period.

    Trigger

    A planned change restarted Prometheus at a time when the WAL count was high.

    Root cause
    Component
    Contributing factor
    Detection

    The team saw that the Prometheus pod had restarted several times after the planned change.

    Remediation
    • raised the Prometheus startupProbe threshold to 30 minutes
    Action items
    • Perform planned Prometheus restarts when the WAL count is lower
    • Set the default CPU and memory requests to meet maximum usage
    • Create a test setup that recreates the live WAL count
    • Explore the memory-snapshot-on-shutdown and auto-gomaxprocs feature flags
    • Explore storing WAL files remotely in a different location
    • Look into a blue-green Prometheus to test changes on a live-like setup before applying them to live
    • Spike into Amazon Managed Prometheus
  3. Symptoms

    At 10:15 on 1 November 2023 a Pingdom check raised a PagerDuty high-priority alert that the "Prometheus - live healthcheck is DOWN". The same alert fired for the third time within a few minutes, and the incident was declared at 10:41.

    Root cause
    Component
    Contributing factor
    –
    Detection

    A Pingdom health check on the live Prometheus failed and raised a PagerDuty high-priority alert.

    Remediation
    • increased the Prometheus readiness probe timeout from 3 to 6 seconds
    Action items
    • Inspect more closely to identify this kind of failure earlier
    • Investigate whether the ingestion of data into the database is too big or too long
    • Check whether executing some queries makes Prometheus work harder and stop responding to the readiness probe
    • Check whether any other service probing Prometheus triggers the restart
    • Check whether regular Velero backups disturb EBS reads and writes and cause the restart
  4. Symptoms

    During a rollout of the Grafana Loki distributor Deployment in one Grafana Cloud Logs environment, the write path went down for about 25 minutes. The newly started distributor pods were OOM-killed over and over, never passed their health and readiness checks, and the rollout stopped making progress.

    Trigger

    Step 1 of moving the Loki ring off a separately deployed key-value store onto embedded memberlist added a new label, gossip_ring_member: 'true', to the distributor pods and Service, together with a small config change, and the change required a rollout of the distributors.

    Root cause
    Component
    Contributing factor
    Detection

    The first clue was kubectl get pods and the kube_deployment_status_replicas_updated metric showing that only 16 of 140 distributor pods had been updated.

    Remediation
    • scaled the distributor Deployment out horizontally so the load spread over more pods with the new label and the rollout could continue
    • reverted the migration step to end the outage
    • set service_ignored_labels:: [$._config.gossip_member_label] and passed it to k.util.serviceFor so the label is no longer copied into the Service selector
    Action items
    • Update the function that generates a Service from a Deployment or StatefulSet to handle edge cases, including this one
    Lessons

    A Service whose selector is built by copying every label of a workload changes which pods it matches as soon as a new label is added. During a rollout it then matches only the new pods, which receive all the traffic before there are enough of them. A few errors during a rollout in other environments hid the problem, because those environments gave distributors more memory and could absorb the shift. Manifest diffs kept for every pull request made it possible to see that the Service selector had changed.

  5. Symptoms

    At 08:00 UTC on 2021-09-06 every service in DFDS's Kubernetes cluster answered with 404. Investigation started five minutes later.

    Trigger

    The automated Kubernetes node rollover on 2021-09-06 restarted all the Traefik v2 pods, five days after a malformed IngressRoute manifest had been applied.

    Root cause
    Component
    Contributing factor
    Detection

    All services returned 404 from 08:00 UTC and root cause investigation started at 08:05. Time to detection was 5 minutes.

    Remediation
    • changed the ALB health check path, which made the targets healthy but did not stop the 404s
    • rolled back by hand to Traefik v1 as the main ingress controller
    • deleted the malformed IngressRoute by hand and confirmed the Traefik v2 bug
    • applied the changes upstream
    Action items
    • Upgrade Traefik to v2.5, where the bug is fixed, and verify that it removes the bug
    • Change the Traefik v2 health check path to something more robust
    • Set up an external liveness probe on the ingress controller
    • Consider workload segmentation to limit the blast zone
    • Look into monitoring the Traefik v2 API for rapid changes
    • Look into smoke testing during and after node rollover
    Lessons

    A malformed IngressRoute did nothing visible for five days and then took down all ingress when every Traefik v2 pod had restarted during a node rollover. Because Traefik v2 failed gracefully, the first signals pointed at the ALB health checks instead of at Traefik. On incident handling, the team concluded that appointing an incident manager could have helped, that the war room meeting should be recorded and a log book kept, that people not involved should only make suggestions in writing, and that a short first round of sharing thoughts and gut feelings is useful.

Check your cluster for this

These 18 cases involve Ingress controller and Container memory limit. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause8

Configuration change2 cases

  1. IL-0063 VPN outage after recreating a Redis StatefulSet restarted the whole Redis cluster without readiness checks
  2. IL-0191 A label selector accidentally added to the Loki distributor Service matched only the new pods of a rollout, which took all write traffic, were OOM-killed and stalled the rollout

Capacity exhaustion6 cases

  1. IL-0581 29CM product display servers lost pods and saturated Netty event loops on the first day of the Igu Week sale
  2. IL-0232 Calico pods in the codfw WikiKube cluster hit their resource limits and crash-looped, taking nodes out one by one
  3. IL-0044 Prometheus OOMKilled in a loop while replaying its write-ahead log after a kube-prometheus-stack upgrade
  4. IL-0046 Prometheus restarted again and again because its WAL replay took longer than the startup probe allowed
  5. IL-0176 Prometheus in a 235-node Kubernetes cluster crash-looped because over two million series exhausted host memory and the kernel OOM killer chose it first, as Burstable QoS gave it oom_score_adj 999
    LINE2020
  6. IL-0503 mybinder.org launches failed after a GKE node ran out of memory and its nginx-ingress proxy pod crash-looped

Dependency failure2 cases

  1. IL-0187 A brief Spring Cloud Config Server downtime failed every client application's liveness probe, because the actuator health check included the config server, and Kubernetes restarted the pods in a kill loop
  2. IL-0103 During an EKS node AMI update, Istio sidecars crash-looped because hundreds of pods restarting at once overloaded the external certificate authority behind istiod

Cloud provider outage1 case

Component
Organisation
  1. IL-0119 ChatGPT web service pods crash-looped on failing health checks after a Cosmos DB failure, leaving too few healthy pods to serve the web layer
    OpenAI2025

Software defect3 cases

Organisation
  1. IL-0495 HubSpot's internal load balancers on Kubernetes were falsely marked unhealthy and the rest collapsed under the traffic
  2. IL-0106 A malformed Traefik IngressRoute triggered a Traefik v2 bug once a node rollover restarted every Traefik pod, and all Kubernetes services returned 404
    DFDS2021
  3. IL-0012 CPU limits and an unpatched kernel CFS quota bug throttled multi-threaded services into stalls, failed health checks and timeouts
    Omio2020

unknown2 cases

  1. IL-0045 Prometheus on the live cluster restarted several times after readiness probe failures, leaving gaps in metrics
  2. IL-0059 Single-master Kubernetes control plane kept dying because the kubelet restarted a healthy etcd on a failing kubeadm liveness probe

Faulty deployment1 case

Organisation
  1. IL-0034 A crashing stats agent sidecar marked every pod unready and the service mesh pulled all services out of traffic
    Airbnb2019

Operator error1 case

Organisation
  1. IL-0054 All ingress traffic lost while draining a GKE node pool because the load balancer only targeted new nodes without ingress-nginx pods