  1. Symptoms

    On the evening of a long-overdue upgrade of a loveholidays production GKE cluster from 1.10.X to 1.12.5-gke.10, planned to take 2 to 2.5 hours, the master upgrade and the first two 7-node NodePools went smoothly. After that the NodePool upgrades slowed to a crawl. Each node is cordoned, drained and upgraded in turn. Even a 14-node cluster at about 5 minutes per node took over an hour, and with about 100 more nodes to go, some of them taking over 15 minutes to drain, the sequential drains were too slow to finish at a reasonable hour.

    Trigger

    A manual upgrade of the GKE masters and NodePools from 1.10.X to 1.12.5-gke.10, two versions at once, on 19 March 2019; GKE's release notes of 14 March had already said that version was no longer available for new clusters or master upgrades because masters showed elevated error rates, but it could still be selected.

    Root cause
    Component
    Contributing factor
    Detection

    The slow drains, zombie nodes and stuck NodePool were seen by the engineer running the upgrade; the broken Ingress was noticed after the upgrade and explained by Google support; the HPA problem was noticed the next day.

    Remediation
    • drained the remaining NodePool nodes ahead of the upgrade with kubectl drain --ignore-daemonsets --delete-local-data
    • deleted the zombie instances from the managed instance group with gcloud compute instance-groups managed delete-instances
    • cancelled the stuck UPGRADE_NODES operation with gcloud beta container operations cancel
    • used kubectl port-forward in place of the broken internal Ingresses
    • scaled down the older of two active ReplicaSets, or triggered a dummy deployment, to bring the HPA back
    Action items
    • Alert when a HorizontalPodAutoscaler is at 70% and at 100% of its capacity
    • Alert when a deployment has had two active ReplicaSets for 30 minutes and for 60 minutes
    • Re-evaluate termination grace periods that were set to arbitrary large values
    • Read the GKE release notes before every cluster upgrade
    • Use auto-upgrade in non-production environments, and manual cluster upgrades with automatic node upgrades in production
    • Keep environments as identical as possible, including resource names
    Lessons

    Read the release notes before upgrading: the target version had been withdrawn five days earlier. Drain time depends on pod configuration, so emptyDir volumes, long grace periods and missing disruption budgets turn a NodePool upgrade into hours. Pre-production only catches problems like the ingress bug if it matches production down to resource names. Auto-upgrades in non-production surface problems early, and a mix of manual cluster upgrades and automatic node upgrades in production keeps clusters current without much effort.

Check your cluster for this

These 8 cases involve Node pool and Node operating system image. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause4

Faulty deployment4 cases

  1. IL-0167 A phased rollout of an LKE software release in Osaka stalled LKE-E cluster creation, version upgrades and control plane ACL changes
    Linode2026
  2. IL-0020 During an EKS 1.30 upgrade the descheduler tried to reschedule every pod on the cordoned nodes at once and production workloads went down
  3. IL-0164 An incremental Linode Kubernetes Engine production update that was missing changes from the previous release made cluster upgrades and node additions fail silently
    Linode2022
  4. IL-0149 Upgrades of AKS clusters on Virtual Machine Scale Sets failed with a 'platform image is not available' error after a service update left a backend service unhealthy

Software defect2 cases

Organisation
  1. IL-0147 AKS nodes behind an HTTP proxy failed to provision with CSE exit code 31 on 202508 node images, because a refactoring stopped the proxy from being used when downloading uncached Kubernetes binaries
  2. IL-0112 The daily node rollover put DFDS's EKS nodes on an AMI later recalled for a kernel issue, causing "PLEG is not healthy" NodeNotReady flaps and pod network timeouts
    DFDS2022

Configuration change1 case

Organisation
  1. IL-0008 An unresponsive OPA validating webhook crash-looped the API server during a GKE master upgrade, and node auto-repair then recreated every node

Cloud provider outage1 case

Organisation
  1. IL-0014 A GKE upgrade to a withdrawn version stalled on slow drains and a stuck node pool, then broke an ingress and confused the HPA