Incident Library
Applied filters SymptomNode NotReadyClear allEvery case under the filters, with no sentence; newest first.
Suggested filters Search, and the values found in your words appear here.

Graph

  • Root cause
  • Component
  • Symptom
  • Contributing factor
  • Case

Cases23 cases

16 to 20 of 23

  1. Symptoms

    Fewer than 20% of the nodes in one Zalando cluster were available. Most nodes reported NotReady at the same moment, and only a handful stayed Ready.

    Root cause
    Component
    Contributing factor
    Remediation
    • none; the nodes recovered on their own after about 15 minutes
  2. Symptoms

    The NU.nl development team got reports that several services on one of its Kubernetes clusters behaved erratically: occasional error pages, slow responses and timeouts. The affected services were mostly internal tools and dashboards.

    Trigger

    A new ElastAlert rule, deployed shortly before from the command line, that fired if the Cloudfront-* Elasticsearch indexes stopped receiving documents; those indexes take a few million requests per hour, and the rule made ElastAlert's memory grow without bound.

    Root cause
    Component
    Contributing factor
    Detection

    Users reported error pages, slow responses and timeouts from several services; no alert fired.

    Remediation
    • terminated the NotReady nodes one by one so the auto-scaling group replaced them (the new nodes also went NotReady, but Prometheus and Grafana landed on a stable node)
    • found the ElastAlert pods' memory growth on the Grafana pod memory dashboard
    • fixed the ElastAlert problem that caused the memory growth
    Action items
    • Define alerts on resource usage such as CPU, memory and disk space
    • Keep researching an alerting strategy that combines Elasticsearch, Prometheus Alertmanager and New Relic
    • Consider exporting metrics out of the cluster and running Grafana outside it, on EC2 or a separate Kubernetes cluster
    • Either visualise the important metrics in the ELK stack or make Prometheus and Grafana more available, and improve the metrics strategy
    • Set resource limits for ElastAlert through the Helm values
    • Configure namespaces with default memory requests and limits
    • Isolate customer-facing workloads from build, logging and monitoring workloads (a dedicated node group, or later a separate tools cluster)
    • Deploy everything through automation such as Jenkins pipelines, and consider a GitOps approach
    • Deploy through a pipeline that includes a smoke test step
    • Make Kubernetes and cloud infrastructure work part of the team's sprints, picked up by all team members while pairing with more experienced members, and hold workshops that go deep into specific topics
    Lessons

    Fixing the root cause covers only a small part of what an incident can teach; the chain of smaller failures around it is where most of the learning is. A pod without a memory limit can take whole nodes down, so limits need defaults at the namespace level. Monitoring that runs inside the cluster it watches goes blind with it. Changes installed by hand from the command line leave the rest of the team without a record of what changed.

  3. Symptoms

    On Friday, January 18, Moonlight's API began returning occasional errors that looked like connection problems with its Redis database. The API checks Redis on every authenticated request to validate the session. At the same time the Kubernetes monitoring reported some nodes and pods as unresponsive.

    Trigger

    The Kubernetes scheduler put several CPU-heavy pods on the same node, including all three replicas of the website and the server-side rendering pods.

    Root cause
    Component
    Contributing factor
    Detection

    API errors that looked like Redis connectivity problems, and Kubernetes monitoring that showed nodes and pods as unresponsive. Google Cloud Support later found the link between sustained 100% CPU and kernel panics.

    Remediation
    • added anti-affinity rules to all major deployments so their pods spread across nodes
    Action items
    • Keep working with Google Cloud support to find and fix the cause of the node kernel panics
    Lessons

    Three replicas give no fault tolerance if the scheduler places them all on one node; anti-affinity rules make the spread explicit. A node failure that comes from the workload itself moves with the workload when the scheduler reschedules it.

  4. Symptoms

    An upgrade of the network subsystem under Target's datacenter OpenStack, meant to cause only a brief disruption, ran into problems and left network connectivity disrupted for several hours. Kafka, which runs on that OpenStack, became intermittently available.

    Trigger

    A network subsystem upgrade in the datacenter OpenStack infrastructure disrupted connectivity for several hours and made Kafka intermittently available.

    Root cause
    Component
    Contributing factor
    Remediation
    • enabled gossip encryption on Consul so messages from the poisoned mesh were rejected
    • stabilized the deployment engine and redeployed the development environment with encryption, terminating instances without it
    • upgraded Consul in place to 1.2.3 and then to 1.3.0
    Action items
    • Reduce how much of an outage a single Docker daemon can cause, together with running smaller and more numerous clusters
    Lessons

    Smaller and more numerous clusters limited the damage: the smaller development clusters and production were not hit the same way as the one large cluster, and dev and prod on one cluster would have been far worse. A Docker daemon shared by many workloads is a brittle failure point. Per-workload logging and metrics sidecars were judged the right design; a shared cluster-level agent would almost certainly have made the problem worse and harder to fix.

  5. Symptoms

    At about 15:00 UTC on 19 July 2018, monitoring alerted on rising 5xx responses from several APIs, most notably pilot and tiles. Logins failed first, because the pilot service fetches the user's profile, and from there all services became unresponsive. Every affected API ran on the production Kubernetes cluster.

    Root cause
    Component
    Contributing factor
    Detection

    Monitoring alerted on an increase in 5xx responses from several APIs, most notably pilot and tiles.

    Remediation
    • restarted the kubelets on the stuck worker nodes, which did not last
    • restarted all worker nodes in a staggered order starting at about 18:00 UTC, which took about 1.5 hours
    Action items
    • Restart nodes on a rolling schedule to keep nodes and kubelets healthy until the fixes land upstream and reach the cloud provider, Microsoft Azure
    Lessons

    When nodes keep falling back to NotReady after kubelet restarts and pods fail on network and DNS errors, a known upstream bug may be the cause; matching the symptoms to the upstream issue tracker, with help from the community, found the cause and the fix candidates.

Check your cluster for this

These 23 cases involve kubelet and Node operating system image. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause8

Capacity exhaustion9 cases

  1. IL-0155 Some DOKS clusters in NYC1 saw intermittent DNS timeouts and NodeNotReady events because CoreDNS ran on shared-CPU Droplet worker nodes
  2. IL-0085 A control plane node of Magic Pages' Kubernetes cluster on Hetzner Cloud ran out of memory, the cluster's own calls then used up the Hetzner API rate limit, and all customer websites were down for about 7.5 hours
  3. IL-0110 A Grafana Agent pod's high memory use and crash-looping Hangfire pods drove a Kubernetes node into system OOM and NotReady, twice in one day
    DFDS2024
  4. IL-0168 Simultaneous cluster auto-upgrades overloaded Scaleway's Kubernetes API, and a node authentication retry loop kept Kapsule and Kosmos nodes NotReady in FR-PAR
  5. IL-0169 The Scaleway Kubernetes API in FR-PAR ran out of memory under simultaneous deployments, and because it also handled node authentication, Kapsule and Kosmos nodes went NotReady
  6. IL-0016 Prometheus on the live cluster ran out of memory and was OOMKilled, and the monitoring node it ran on went NotReady
  7. IL-0064 CPU-heavy pods packed onto one Google Cloud node drove it to kernel panics, and the crash moved from node to node until the site was down
  8. IL-0036 A reindex Job that kept failing exhausted one node after another until the whole cluster was down
  9. IL-0040 Parallel Helm installs saturated small gp2 root volumes on a kops cluster and left all three workers NotReady with the kubelet or Docker down

DNS or network fault1 case

Contributing factor
–
Organisation
  1. IL-0154 Line cards on an SFO3 core router rebooted together and halved backbone capacity, and DOKS nodes whose guest networking did not recover stayed NotReady with degraded API servers until all affected nodes in the SFO3 DOKS fleet were recycled

Dependency failure2 cases

  1. IL-0021 GKE GPU nodes on Container-Optimized OS could not download NVIDIA drivers (403 Forbidden) and came up without working GPUs
  2. IL-0073 Intermittent Kafka connectivity overloaded Docker daemons, set off a node rescheduling cascade and poisoned the Consul gossip mesh
    Target2019

Configuration change2 cases

  1. IL-0153 DOKS worker nodes went NotReady at 06:00 UTC on three days because a systemd timer in the Debian image ran apt upgrade and killed it mid kernel upgrade, breaking node networking
  2. IL-0035 Worker nodes went NotReady after a new ElastAlert rule without memory limits used up node memory
    NU.nl2019

Hardware failure1 case

Contributing factor
Organisation
  1. IL-0185 A disk failure made the first control plane node of a Kubespray cluster read-only, and recovery needed the Kubespray inventory reordered and a new control plane node joined

Breaking change in an upgrade1 case

Organisation
  1. IL-0198 An automatic Ubuntu security update restarted systemd-networkd, which flushed the IP rules Cilium relied on and cut more than 60 percent of Datadog's Kubernetes nodes off the network across regions and cloud providers

Software defect5 cases

  1. IL-0112 The daily node rollover put DFDS's EKS nodes on an AMI later recalled for a kernel issue, causing "PLEG is not healthy" NodeNotReady flaps and pod network timeouts
    DFDS2022
  2. IL-0029 Slow user-facing services from CPU throttling on containers that used far less CPU than their limit
    Buffer2020
  3. IL-0030 Most nodes of a cluster went NotReady together for 15 minutes while the API server sat behind an AWS ELB
  4. IL-0074 All AirMap platform services down as worker nodes went NotReady and pods crash-looped on network and DNS failures
    AirMap2018
  5. IL-0038 kubelet rollout hit a Kubernetes bug and left every node in a cluster NotReady, triggering mass pod eviction
    Oath2018

Cloud provider outage2 cases

  1. IL-0172 An AWS Tokyo data centre cooling failure took down 6 of 60 CockroachDB nodes on Kubernetes within 22 minutes, and ranges lost quorum because the Helm-deployed cluster had no availability zone locality configured
  2. IL-0193 A GCP persistent disk degradation took down a Cassandra StatefulSet whose OrderedReady policy blocked recovery, and Metrictank could not reconnect to the recreated pods, causing a 23-hour Graphite query outage