  1. Symptoms

    Every service in the homelab Kubernetes cluster stopped answering: the V-Rising server, Grafana, Jellyfin and Linkding were all unreachable, and the Kubernetes API was down, so the cluster could not be managed at all. The outage was found by hand, about 3 hours after it began, when someone tried to use the services.

    Trigger

    A power outage forced the Kubernetes master node to reboot.

    Root cause
    Component
    Contributing factor
    Detection

    Manually, when someone tried to access the services; there were no automated alerts.

    Remediation
    • Connected a monitor to the master node and read the boot logs, which showed the kernel panic
    • Booted the previous kernel version, which brought the system back
    • Removed the broken Nvidia packages with sudo apt-get remove --purge '^nvidia-.*' and ran sudo dpkg --configure -a
    • Found remaining broken packages with dpkg -l | grep -v ^ii and removed them by hand
    • Ran sudo apt-get install -f and reinstalled linux-headers-$(uname -r)
    • Rebooted and confirmed the kernel panic was gone
    Action items
    • Make sure GPU driver installations fully succeed, or revert immediately when they fail
    • Move the cluster to a high-availability control plane
    • Expose the Kubernetes API through a load balancer in the HA setup
    • Set up a ticketing system to record incidents and their resolution
    • Write predefined troubleshooting workflows to shorten response time
    • Add infrastructure monitoring such as Prometheus and Grafana
    • Add blackbox HTTP and TCP checks from outside the cluster for critical services
    Lessons

    A driver installation that fails half-way can leave kernel packages broken without any visible effect until the next reboot, which may come weeks later and at the worst time. A failed DKMS build should be fixed or reverted at once. With a single master node and no monitoring from outside the cluster, one unbootable machine meant a total outage that nobody was told about; the fix itself was simple once the boot logs were seen.

  2. Symptoms

    In January 2022 an etcd memory spike overloaded the Kubernetes control plane of one of Render's clusters in Frankfurt. At first only operations that need the control plane failed: new deploys and cron job runs.

    Trigger

    A memory spike in etcd overloaded the cluster's control plane.

    Root cause
    Component
    Contributing factor
    Action items
    • Run CoreDNS on data plane nodes instead of control plane nodes
    • Run etcd on dedicated nodes
    Lessons

    CoreDNS can keep answering from its in-memory cache while the API server is down, but it cannot initialise without it. With CoreDNS on the control plane nodes, a reboot or restart during a control plane outage turned a failure of deploys and cron jobs into a failure of requests to services that were already running. The core problem was that the data plane was not isolated enough from the control plane: even without the reboot, the etcd memory spike alone could have forced CoreDNS to restart.

  3. Symptoms

    Alerts fired at 3:13 PM PST on 11 December 2024, and from 3:16 PM every OpenAI service was significantly degraded or completely unavailable, including ChatGPT, the API and Sora. The status page reported API calls returning errors and difficulties logging in to platform.openai.com and ChatGPT. Customer impact peaked at 3:40 PM.

    Trigger

    At 2:23 PM PST a change introducing a new telemetry service, which collects detailed Kubernetes control plane metrics, was merged and the deployment pipeline started. Between 2:51 PM and 3:20 PM the change was applied to all clusters.

    Root cause
    Component
    Contributing factor
    Detection

    OpenAI's detection tools worked: alerts fired at 3:13 PM PST, a few minutes before customer impact began at 3:16 PM, and the root cause was identified at 3:16 PM.

    Remediation
    • Scaled clusters down to reduce the total Kubernetes API load
    • Blocked network access to the Kubernetes admin APIs so no new expensive requests arrived
    • Scaled up the Kubernetes API servers
    • Removed the telemetry service once enough control was back
    • Moved traffic from impacted clusters to healthy ones
    • Intervened manually in clusters where simultaneous resource downloads saturated resource limits
    Action items
    • Put every infrastructure configuration change through a phased rollout with continuous monitoring of both the service workloads and the clusters, including the Kubernetes control plane
    • Run fault injection tests in which the data plane runs without the control plane for longer, and tests that roll out bad changes on purpose to check detection and rollback
    • Build break-glass mechanisms so engineers can reach the Kubernetes API servers in any circumstances
    • Decouple the Kubernetes data plane from the control plane so that service discovery for critical workloads does not depend on the control plane
    • Speed up recovery with better caching and dynamic rate limiters for resources needed at cluster startup, and regular drills that rapidly replace an entire cluster
    Lessons

    Several systems and processes failed at once and interacted in unexpected ways: tests did not catch the change's effect on the Kubernetes control plane, DNS caching put a delay between the change and the failures, and being locked out of the control plane made remediation very slow. Because service discovery used Kubernetes DNS, the control plane was carrying load for product traffic even though the data plane was meant to be independent of it.

  4. Symptoms

    From 10:15 am PT on 25 November 2024 a large share of both API and ChatGPT traffic failed with timeouts and 503 errors.

    Trigger

    A global change to Kubernetes namespace labels caused the networking layer to recompute metadata. The change had rolled out to the small clusters without problems.

    Root cause
    Component
    Contributing factor
    Remediation
    • moved workloads out of the impacted clusters by hand
    • with the cloud provider, scaled up the number of control plane nodes while scaling down the number of data plane nodes, which let the control planes recover
    Action items
    • Lock namespace changes so this incident cannot recur
    • Freeze certain types of infrastructure deploys
    • Allowlist identities to prevent a recurrence of this class of incidents
    • Improve the GPU load balancing logic so traffic is re-routed automatically and more effectively when possible
    • Improve change management for fleet-wide infrastructure changes
  5. Symptoms

    From 17 October 2024, packets through the vSwitch that joined Namespace's bare metal machines at one provider in the fra3 region were dropped at random. Retries in TCP, QUIC and the Namespace control plane hid most of it, but the SLO error budget for latency targets on key interactions began to burn.

    Trigger

    Random packet drops on the bare metal provider's vSwitch from 17 October 2024; for the second outage, a rate of Kubernetes changes that the slow NVMe on one control plane node could no longer keep up with.

    Root cause
    Component
    Contributing factor
    Detection

    SLO-based monitoring of latency targets showed the error budget burning while retries hid the individual packet drops.

    Remediation
    • diverted all customer traffic from fra3 to other regions
    • connected each provider machine to the zrh1 cluster over Wireguard instead of the vSwitch
    • repaved every fra3 machine with a new identity, certificates and encryption-at-rest keys, dropping regional caches to recover faster
    • cloned existing datasets in a more distributed way to speed up repaving the machines
    • added machines back to the new region in batches and returned the region to the compute pool
    • redirected workloads away from zrh1 during the second outage
    • cloned the failing control plane node's key state to a higher-capacity node that took over its role and IP address
    Action items
    • Credit all instances that ran during the outages back to customers
    • Build up backup regions and solutions so a similar event has options that do not affect customers
    Lessons

    Running hot with a delayed hardware delivery left no room to take a region out, so fixing a provider network fault turned into a global capacity shortage. After one outage the team was anchored on its cause and first looked for network problems in the second outage, which had a different cause: a control plane node whose disk could not keep up with the Kubernetes change rate.

Check your cluster for this

These 28 cases involve Kubernetes API server and etcd. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause9

Credential exposure1 case

Contributing factor
  1. IL-0069 Attackers stole a high-privilege service account token from a production Kubernetes cluster and used it to reach a cryptocurrency exchange's financial systems

Certificate or credential expiry3 cases

  1. IL-0183 kubeadm's one-year leaf certificates expired, so kube-apiserver could not reach etcd, restarted in a loop and left the cluster unreachable
  2. IL-0113 The managed GKE control plane of Webhook Relay's main cluster failed because its API server certificates had never been rotated, and a manual credential rotation reported success without taking effect
  3. IL-0184 JupyterHub's KubeSpawner could not create containers and kubectl was refused because the API server and other internal certificates of a kubeadm cluster had expired
    dbhang2021

Software defect5 cases

  1. IL-0138 A failed Nvidia driver build left broken kernel packages on the only Kubernetes master node, which hit a kernel panic on reboot after a power outage and took the homelab cluster down for six days
  2. IL-0077 EKS cluster went read-only for over seven hours after Kyverno ephemeralreports filled the etcd database past its size limit
  3. IL-0030 Most nodes of a cluster went NotReady together for 15 minutes while the API server sat behind an AWS ELB
  4. IL-0072 High etcd write latency made the API servers return stale data, and the production cluster flipped between two views of its state
  5. IL-0003 linkerd lost Kubernetes service discovery after an etcd reconfiguration, and restarting every linkerd instance turned failed payments into a full platform outage
    Monzo2017

Capacity exhaustion9 cases

  1. IL-0204 An etcd memory spike overloaded the control plane of a Render Frankfurt cluster, and DNS then failed because CoreDNS ran on the rebooted control plane nodes and could not start without the API server
    Render2024
  2. IL-0168 Simultaneous cluster auto-upgrades overloaded Scaleway's Kubernetes API, and a node authentication retry loop kept Kapsule and Kosmos nodes NotReady in FR-PAR
  3. IL-0195 The kube-apiservers of a cluster with more than 200 nodes ran out of memory and crashed one after another under mass LIST requests from Cilium agents
    Palark2023
  4. IL-0165 Some LKE users in Frankfurt could not reach their kube-apiservers with kubectl after backend services failed under memory constraints
    Linode2023
  5. IL-0194 After a kube-apiserver restart, pod LIST requests from every pod of a Vector DaemonSet nearly tripled etcd memory and restarted all master nodes
    Palark2023
  6. IL-0002 CI builder pods could not get AWS IAM credentials because kubelet fell minutes behind its API rate limit
  7. IL-0076 Kubernetes masters went down after Dex filled etcd with AuthRequest objects and deleting its namespace started an endless list-and-timeout loop
  8. IL-0075 Kubernetes API servers pegged on CPU when the cluster grew to about 290 nodes, traced to Datadog agents polling the API
  9. IL-0031 Kubernetes API server OOM-killed, leaving the Skipper ingress without routes; the talk points to a misconfigured CronJob manifest

Configuration change6 cases

  1. IL-0005 A new telemetry service overloaded the Kubernetes API servers of large clusters and broke DNS-based service discovery for all OpenAI services
    OpenAI2024
  2. IL-0118 A global change to Kubernetes namespace labels made the networking layer recompute metadata and overwhelmed the control planes of three of OpenAI's largest GPU clusters
    OpenAI2024
  3. IL-0152 An incorrect configuration applied during maintenance made an internal infrastructure cluster automatically delete the control planes of 200 DOKS clusters in FRA1
  4. IL-0068 Anonymous access to the Kubernetes API server used to plant a ClusterRoleBinding backdoor and a cryptominer DaemonSet
  5. IL-0108 An Alcide admission controller applied to the production cluster during a workshop made create and update requests on Deployments time out
    DFDS2020
  6. IL-0008 An unresponsive OPA validating webhook crash-looped the API server during a GKE master upgrade, and node auto-repair then recreated every node

Cloud provider outage1 case

Organisation
  1. IL-0084 Packet drops on a bare metal provider's vSwitch forced Namespace to rebuild its fra3 region and left global capacity short, and the next day slow NVMe writes on a control plane node drove the Kubernetes API server to very high CPU

DNS or network fault1 case

Contributing factor
–
Organisation
  1. IL-0154 Line cards on an SFO3 core router rebooted together and halved backbone capacity, and DOKS nodes whose guest networking did not recover stayed NotReady with degraded API servers until all affected nodes in the SFO3 DOKS fleet were recycled

Breaking change in an upgrade1 case

Organisation
  1. IL-0060 Kubernetes 1.24 upgrade removed the master node label that Calico route reflectors selected on, dropping all pod routes and taking Reddit down for 314 minutes
    Reddit2023

unknown1 case

Organisation
  1. IL-0059 Single-master Kubernetes control plane kept dying because the kubelet restarted a healthy etcd on a failing kubeadm liveness probe