Cases8 cases

3 to 7 of 8

  1. Symptoms

    Services on Buffer's kops-managed cluster on AWS (about 60 nodes and 1500 containers) answered more slowly than they should have. The container throttling metric showed that many containers were being throttled whatever their CPU usage was, including containers that never came close to their CPU limit.

    Trigger

    CPU limits on user-facing services, enforced through CFS quota by a Linux kernel with a bug that throttled containers even when they were well under their limit.

    Root cause
    Component
    Contributing factor
    Detection

    While reviewing the container throttling metric, the team noticed many containers being throttled even though their CPU usage stayed far below their limits.

    Remediation
    • removed CPU limits from all services directly or indirectly on the users' critical path
    • moved those services to dedicated tainted nodes and gave them matching tolerations
    • set each service's CPU request to its peak usage over a few months plus a margin of more than 20%, and set memory requests the same way
    Action items
    • Move nodes to a kernel that contains the CFS throttling fix (4.19 or later), which for Buffer means a kops version whose host image is Ubuntu 20.04
    • After the kernel upgrade, check whether throttling is fully gone and update the post
    Lessons

    A CPU limit can slow a service down even when the service uses a small part of it, because of how the kernel enforces CFS quota on older kernels; the throttling metric shows it, the CPU usage graph does not. Upgrading the kernel is the safer fix. Removing limits works for latency, but only together with honest CPU and memory requests, isolation of the unbounded services, and monitoring of node usage, since unbounded containers can starve the kubelet.

  2. Symptoms

    Right after an updated RedisFailover resource was rolled out, the large Redis database lost all its data and the service went down; the data had to be restored from a backup taken just before the change.

    Trigger

    A RedisFailover change that raised the number of Redis replicas from one to two and, in the same rollout, lowered the containers' memory requests and limits from 22 GB to 19 GB.

    Root cause
    Component
    Contributing factor
    Remediation
    • restored the Redis data from the backup prepared before the rollout
    Action items
    • Report the readiness probe flaw to the Redis Operator project and test the developers' fix
    • Reconsider the use of the Spotahome Redis Operator
    • Clean up the Redis databases and fix the application code that created the excess keys
    • Consider Redis built-in clustering and sharding
    Lessons

    Changing the replica count and the pod resources in one rollout turned a seemingly harmless change into a rolling restart of the only pod with data while the new replica was still empty. A readiness probe that only checks that Redis answers a ping does not tell whether a replica has finished syncing. Operators for critical stateful components need to be evaluated for maturity before production use, and the dump.rdb file should be backed up before any change to the Redis cluster.

  3. Symptoms

    After Ravelin moved its API layer from VMs into its GKE cluster behind a Kubernetes Ingress, the integration tests occasionally received 502 errors.

    Trigger

    Pods behind the Ingress being removed by their controller, as happens during rolling deploys and scaling.

    Root cause
    Component
    Contributing factor
    Detection

    Integration tests occasionally received 502 errors.

    Lessons

    Removing a pod's endpoint and signalling the pod happen at the same time, and an ingress can take a long time to catch up. A pod behind an ingress should keep serving after SIGTERM until its grace period ends, and the grace period should be longer than the load balancer's reprogramming time.

  4. Symptoms

    On a Sunday, a team using one of Skyscanner's Kubernetes clusters manually paged the out-of-hours Kubernetes support because their service showed elevated latency, worst at the p90 and maximum levels.

    Trigger

    Upgrading the HAProxy ingress controller to v0.6 and going back from Service virtual IPs to individual pod IPs as backends, on the understanding that the sort-backends flag introduced in v0.5, false by default, meant backends were randomly shuffled.

    Root cause
    Component
    Contributing factor
    Detection

    A cluster user manually paged the out-of-hours Kubernetes support about elevated latency; Prometheus queries then showed the uneven request distribution across pods.

    Remediation
    • switched the affected service from pod IPs back to the Service virtual IP through a config change in the internal deployment tool Slingshot
    • patched the controller to keep each backend's servers in an insertion-ordered slice and changed the template to iterate over that slice
    • tested the patch in sandbox clusters and rolled it out to the production clusters
    Action items
    • Run the internal controller patch in production and return to pod IPs as the default backends
    • Raise the problem upstream with a GitHub issue and pull request
    • Test changes to cluster components against the specific behaviour and conditions that matter
    Lessons

    The team already knew that sorted backends cause hot-podding and still did not test the new flag well enough to see that it did not work; changes to cluster components need tests aimed at the exact behaviour that matters, under conditions like production. A keyword can behave differently in different parts of a language: range over a map is unordered in Go code but sorted in text/template. A small cluster component can do outsized harm to every user of the cluster and, in the end, to customers.

  5. Symptoms

    Services that used the team's Redis-dependent library crashed on start-up, and their teams reported it to the ops members. The Spring Boot logs showed the applications failing to resolve the Redis hostname during bean initialisation.

    Root cause
    Component
    Contributing factor
    Detection

    Service teams reported start-up crashes to the ops members of the team; later the resolution failures were seen in Kibana.

    Remediation
    • set ndots to 4 with a dnsConfig block in the Kubernetes deployment manifests
    • corrected the maximum connection pool size in the Redis library, cutting Redis connections by about 70%
    Action items
    • Test Debian glibc-based base images added to the image library to see whether they resolve the DNS problems
    • Update dependencies to newer Netty versions
    Lessons

    With ndots:5, a name outside the cluster that has fewer than five dots is first tried with every cluster search domain. Adding a trailing dot avoids that, but only if every library in the path accepts it, and the Netty version in use did not. The ndots change is a workaround that will not hold forever. The author would like better alerting for this kind of failure but notes that alerts on one-off DNS failures are not wanted.

Check your cluster for this

These 8 cases involve Ingress controller and Node operating system image. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause1

Software defect8 cases

  1. IL-0058 Argo CD deleted namespaces shared by several applications, leaving about 97 applications stuck Missing and OutOfSync
  2. IL-0171 Karpenter node auto-repair replaced EKS GPU nodes about 10 minutes after they became Ready, in a loop, because the Bottlerocket NVIDIA AMI lacked libdcgm.so and set AcceleratedHardwareReady to False
    Inflab2025
  3. IL-0029 Slow user-facing services from CPU throttling on containers that used far less CPU than their limit
    Buffer2020
  4. IL-0196 Adding a second Redis replica and lowering memory limits in one RedisFailover change restarted the only Redis pod that held data, and Sentinel promoted the empty new replica, erasing the data
    Palark2020
  5. IL-0062 Intermittent 502 errors behind a GKE Ingress because pods shut down before the load balancer stopped sending them traffic
  6. IL-0011 HAProxy ingress piled requests onto the same pods because a Go template visited the backend map in sorted pod IP order
  7. IL-0050 Pods on Kubernetes failed to resolve an external Redis hostname because of ndots:5, the musl resolver in Alpine images, and Netty's DNS resolver
  8. IL-0051 A third-party log shipping client leaked file descriptors with every new container until nodes failed with too many open files