  1. Symptoms

    Customers of DigitalOcean Managed Kubernetes (DOKS) saw worker nodes go NotReady between 06:00 and 07:00 UTC and stay unavailable, taking down the services on them, until the nodes were replaced or rebooted; some nodes needed several replacements or reboots. The first sporadic reports on October 8 said replacing the node fixed it. The same thing happened again around 06:00 UTC on October 9, more widely and across many regions, and again on October 10. Only clusters on versions 1.27.6-do.0 and 1.28.2-do.0 were affected.

    Trigger

    A systemd timer in the DigitalOcean Debian image started apt upgrade daily at 06:00 UTC, with a random delay of up to 60 minutes.

    Root cause
    Component
    Contributing factor
    Detection

    Sporadic customer reports of failed worker nodes arrived at 07:43 UTC on October 8; internal incident response started at 07:10 UTC on October 9 after broader impact across regions.

    Remediation
    • Advised customers to replace or reboot affected worker nodes
    • Arranged SSH and console access to worker nodes while they were healthy, and live-debugged an affected node on October 10
    • Released a DaemonSet to all affected clusters that disables the apt upgrade systemd timer on every worker node
    • Released new node images without the auto-update process
    Action items
    • Disable the timer during node provisioning, then remove the DaemonSet from all clusters
    • Add a check to the internal conformance test suite for new cluster versions that the auto-upgrade process and other unwanted timers stay disabled
    • Support logging into worker nodes even when normal access paths are broken
    Lessons

    An operating system auto-update timer left enabled in a node image can change the kernel and systemd underneath Kubernetes, and a timeout that kills the upgrade half-way can leave a node without networking. Failures that start at the same time every day point to a scheduled job on the nodes, and systemd timers belong on that list next to cron jobs. When the failure takes out a node's network, an investigation that depends on logging into the node stalls; access paths that work while the node is broken shorten diagnosis.

  2. Symptoms

    Between 06:00 and 07:00 UTC on 8 March 2023, Kubernetes nodes in several Datadog regions lost network connectivity at the same time, on AWS, Google Cloud and Azure. All services across multiple regions were affected, including the regions that host Datadog's CI/CD and automation tools. Datadog's regions are not connected to each other and changes are rolled out one region at a time, so a simultaneous failure on several cloud providers looked implausible at first.

    Trigger

    On 7 March 2023 Ubuntu published a systemd patch for a CVE (249.11-0ubuntu3.7). Ubuntu's default unattended upgrades installed it on the nodes between 06:00 and 07:00 UTC on 8 March, and installing it restarted systemd-networkd.

    Root cause
    Component
    Contributing factor
    Remediation
    • restarted thousands of disconnected instances on Google Cloud and Azure through the cloud APIs, keeping their local disks
    • rebuilt the data lost with terminated AWS instances' local disks through replication, reprocessing and restores from backup
    Lessons

    A change in a base operating system component can stay dormant for months until something restarts that component. Here the trigger was a security patch, and the change reached every region at once because automatic OS updates ran outside the progressive, region-by-region process used for every other change. Cloud providers react differently to an instance that loses its network. Google Cloud and Azure left the instances running, so a restart recovered them with their disks; AWS replaced them quickly, which brought stateless services back fast but destroyed the local-disk data the stateful services needed.

  3. Symptoms

    At 08:00 UTC on 2021-09-06 every service in DFDS's Kubernetes cluster answered with 404. Investigation started five minutes later.

    Trigger

    The automated Kubernetes node rollover on 2021-09-06 restarted all the Traefik v2 pods, five days after a malformed IngressRoute manifest had been applied.

    Root cause
    Component
    Contributing factor
    Detection

    All services returned 404 from 08:00 UTC and root cause investigation started at 08:05. Time to detection was 5 minutes.

    Remediation
    • changed the ALB health check path, which made the targets healthy but did not stop the 404s
    • rolled back by hand to Traefik v1 as the main ingress controller
    • deleted the malformed IngressRoute by hand and confirmed the Traefik v2 bug
    • applied the changes upstream
    Action items
    • Upgrade Traefik to v2.5, where the bug is fixed, and verify that it removes the bug
    • Change the Traefik v2 health check path to something more robust
    • Set up an external liveness probe on the ingress controller
    • Consider workload segmentation to limit the blast zone
    • Look into monitoring the Traefik v2 API for rapid changes
    • Look into smoke testing during and after node rollover
    Lessons

    A malformed IngressRoute did nothing visible for five days and then took down all ingress when every Traefik v2 pod had restarted during a node rollover. Because Traefik v2 failed gracefully, the first signals pointed at the ALB health checks instead of at Traefik. On incident handling, the team concluded that appointing an incident manager could have helped, that the war room meeting should be recorded and a log book kept, that people not involved should only make suggestions in writing, and that a short first round of sharing thoughts and gut feelings is useful.

  4. Symptoms

    During a cluster upgrade, all traffic to Pusher's products stopped. The speaker recalls that requests were failing with 500 errors.

    Trigger

    A cluster upgrade replaced nodes, so the bridge pods restarted and loaded a ConfigMap that had been changed three or four weeks earlier.

    Root cause
    Component
    Contributing factor
    Action items
    • Build and run Wave so that changes to ConfigMaps and Secrets roll out new pods immediately
    Lessons

    A ConfigMap change does not restart the pods that use it, so for an application that cannot reload its configuration the change takes effect only when pods are next replaced, possibly weeks later during unrelated work. Tie configuration to the pod template so a bad change fails at the moment it is made.

Check your cluster for this

These 6 cases involve Cloud load balancer and Ingress controller. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause3

Software defect2 cases

  1. IL-0138 A failed Nvidia driver build left broken kernel packages on the only Kubernetes master node, which hit a kernel panic on reboot after a power outage and took the homelab cluster down for six days
  2. IL-0106 A malformed Traefik IngressRoute triggered a Traefik v2 bug once a node rollover restarted every Traefik pod, and all Kubernetes services returned 404
    DFDS2021

Breaking change in an upgrade2 cases

Organisation
  1. IL-0203 A routine Kubernetes cluster system update made the AWS Load Balancer Controller fail, so new pods were never registered with the ALB and Honeycomb's EU1 ingest and UI went down once the last old pods were replaced
  2. IL-0198 An automatic Ubuntu security update restarted systemd-networkd, which flushed the IP rules Cilium relied on and cut more than 60 percent of Datadog's Kubernetes nodes off the network across regions and cloud providers

Configuration change2 cases

  1. IL-0153 DOKS worker nodes went NotReady at 06:00 UTC on three days because a systemd timer in the Debian image ran apt upgrade and killed it mid kernel upgrade, breaking node networking
  2. IL-0066 Broken ConfigMap change lay dormant for weeks, then took down Pusher's edge proxy when a cluster upgrade replaced its pods