Incident Library
Applied filters ComponentDatabase failover managerFactorChange with a delayed effectClear allEvery case under the filters, with no sentence; newest first.
Suggested filters Search, and the values found in your words appear here.

Graph

  • Root cause
  • Component
  • Symptom
  • Contributing factor
  • Case

Cases2 cases

1 to 2 of 2

  1. Symptoms

    On the event day of a global game, with close to 1000 rps per MySQL instance even after sharding and replication, a master instance stopped because of a host failure. MHA failed over automatically as usual and the service kept running, but one of the three replicas hit a replication error and could no longer follow the latest data.

    Trigger

    Under heavy load on a game event day, a MySQL master instance stopped because of a host failure, and MHA started an automatic failover.

    Root cause
    Component
    Contributing factor
    Remediation
    • Removed the replica that could not apply data from service
    Lessons

    MHA had not followed a mysqlbinlog change in MySQL 5.7.9, so under specific conditions bringing replicas up to date during failover failed. Running MySQL at large scale means meeting rare events like this, which only show when a master stops suddenly under load.

  2. Symptoms

    On 10 July 2019 the Stripe API failed a substantial majority of requests twice, from 16:35 to 17:02 UTC and from 21:14 to 22:47 UTC. In the first period automated monitoring detected within a minute that a database cluster had failed to elect a new primary.

    Trigger

    The primary node of a database cluster failed at 16:35 UTC while one shard had several stalled nodes. The second period was set off by rolling the election protocol back to the previous minor version at 20:42 UTC.

    Root cause
    Component
    Contributing factor
    Detection

    Automated monitoring detected the failed election within a minute, and the team was alerted at 16:36 UTC. The second period was announced at 21:14 UTC by automated alerts that some shards in the cluster were unavailable.

    Remediation
    • Restarted all nodes of the database cluster, which forced a successful primary election
    • Updated the production configuration and restarted the database cluster's nodes
    • Ramped traffic back up, putting services for user-initiated API requests first
    Action items
    • Alert when nodes stop reporting their replication lag
    • Alert when a shard enters a state that could trigger the election fault
    • Work with the database maintainers on a fix for the underlying fault
    • Add circuit breaking on failed operations to particular database clusters
    • Use fault isolation to contain the impact of a single failed shard
    • Limit the resources used by clients that keep retrying failed requests
    • Add procedures and tooling that make rapid configuration changes during incident response safer
Check your cluster for this