Incident Library
Applied filters FactorNo runbookClear allEvery case under the filters, with no sentence; newest first.
Suggested filters Search, and the values found in your words appear here.

Graph

  • Root cause
  • Component
  • Symptom
  • Contributing factor
  • Case

Cases10 cases

1 to 5 of 10

  1. Symptoms

    From 10:03 UTC on 29 September 2026, requests to Azure OpenAI Service, Foundry Agent Service, Foundry Models and Azure AI services in Sweden Central failed intermittently, took longer, or returned HTTP 500 and 503 errors. At 10:17 UTC service monitoring raised an alert on elevated failure rates for Azure OpenAI Service requests in the region.

    Trigger

    At about 09:38 UTC a planned deployment of an internal service in Sweden Central cleared that service's caches during the region's peak traffic hours.

    Root cause
    Component
    Contributing factor
    Detection

    Service monitoring detected elevated failure rates for Azure OpenAI Service requests in the region at 10:17 UTC and alerted the engineering teams; engineers were engaged at 10:28 UTC.

    Remediation
    • reconfigured the backend service's automated health check so it no longer depended on remote connectivity, which stopped the restart loop
    Action items
    • Reconfigure the backend service's automated health check so it no longer depends on connectivity to its database layer
    • Add monitoring and alerting on the load and latency of the caching layer used by the backend service
    • Update troubleshooting and procedural guidance for connection exhaustion scenarios for on-call engineers
    • Add throttling and rate limiting to protect the backend service from sudden traffic increases (estimated October 2026)
    • Increase the resource capacity of the caching layer used by the backend service across regions (estimated October 2026)
    • Improve diagnostic metrics and automated detection to identify such issues more quickly (estimated October 2026)
    • Partition the caching layer used by the backend service to increase its throughput (estimated December 2026)
    Lessons

    A health check that depends on a remote dependency turns a dependency problem into a restart loop: instances that cannot reach the database are killed, the remaining ones take more load and retries, and adding instances or resources does not help until the check itself is changed. Clearing a cache during peak traffic can multiply load on the backend behind it, especially when cache-read defects let lookups bypass the cache. Connection exhaustion was hard to see because the existing network and diagnostic metrics did not show it.

  2. Symptoms

    On 19 August 2026 the first equipment-level signs in Nebius's us-central1 region appeared around 09:40 UTC: the InfiniBand fabric degraded and GPU over-temperature alerts began to accumulate. Customer reports followed shortly after 10:00. At 10:15 on-call engineers were paged on critical component temperature alerts, and the incident was declared at 10:21.

    Trigger

    A storm-related event at the data center building took the building management system offline and shut down the chilled-water cooling loop.

    Root cause
    Component
    Contributing factor
    Detection

    No facility-level alert fired, because the storm also disabled the building management system that monitors the facility. Engineers acted on component over-temperature alerts that paged on-call at 10:15 UTC, after InfiniBand degradation, GPU over-temperature alerts and customer reports; the temperature rise from about 09:15 was visible on dashboards but had no alert.

    Remediation
    • had the facility operator switch cooling to manual bypass mode and opened rack rear doors to vent heat
    • re-energised tripped racks, control-plane racks first
    • restored the regional infrastructure control plane by manual intervention
    • restarted block-storage host components to clear stale disk attachment state
    • raised the VM recovery rate limits by hand for the region-scale recovery
    • started the affected Managed Kubernetes control-plane instances by hand
    • applied a controlled stop and start to control-plane instances whose data disk had been left unattached
    • identified and started 104 customer VMs that the incident had stopped
    Action items
    • Complete a joint resilience review with the facility operator covering redundancy of facility-management and monitoring systems, cooling that keeps running when those fail, electrical protection of cooling equipment and on-site response
    • Add facility-level environmental alerting on cooling plant state and room temperature trend that pages on-call independently of the building management system
    • Set up a documented emergency escalation path with the facility operator, with an on-call contact tree and guaranteed response times
    • Define an emergency heat-load reduction procedure with criteria, ownership and mechanics for shutting down or degrading workloads during a cooling loss
    • Establish a dependency-ordered region cold-start procedure with clear ownership for each service layer
    • Run regular region-scale recovery drills that cover VMs, storage attachments and Managed Kubernetes clusters
    • Fix the disk-attachment bug that extended the Managed Kubernetes outage and deploy the fix to all production regions
    • Improve the recovery policies Compute users can configure, and move all Managed Kubernetes control-plane nodes to the improved policy
    • Automate reconciliation of stale storage attachment state after abrupt host failures
    • Remove in-region dependencies from monitoring startup and recovery, and extend cross-region monitoring
    • Make regional health checks used for global traffic management reflect real service availability
    Lessons

    Facility monitoring that runs on the same system it watches goes silent in exactly the failure it should report, and with no alert on the room temperature trend there was no practical window to shed heat load in a controlled way. A cold start of a whole region exercised recovery paths built for isolated failures: single-attempt VM recovery, conservative rate limits and stale disk attachments all needed manual work. The longest part of the outage was restoring customer resources, Managed Kubernetes control planes above all, so Nebius is extending its recovery drills to that layer.

  3. Symptoms

    At 11:48 PM PDT on 19 October 2025, every system that reached DynamoDB in us-east-1 through the public regional endpoint started getting DNS failures and could not connect. This included customer traffic and internal AWS services that depend on DynamoDB. DynamoDB global table replicas in other regions still answered but fell behind in replication to and from us-east-1.

    Trigger

    One DNS Enactor, slowed by unusually high retry delays, applied a much older DNS plan to the regional DynamoDB endpoint just as another Enactor that had applied the newest plan ran its clean-up, which deleted that older plan and with it every IP address of the endpoint.

    Root cause
    Component
    Contributing factor
    Detection

    DNS failures to DynamoDB began immediately at 11:48 PM PDT and the engineering teams of affected AWS services were engaged at once; by 12:38 AM they had identified DynamoDB's DNS state as the source. The later NLB health check problem was detected by monitoring at 6:52 AM.

    Remediation
    • applied temporary mitigations by 1:15 AM that let some internal services reach DynamoDB and repaired key internal tooling
    • restored all DynamoDB DNS information by 2:25 AM through manual operator intervention
    • throttled incoming work and selectively restarted DWFM hosts from 4:14 AM so droplet leases could be re-established
    • reduced the load on Network Manager to bring network configuration propagation times back to normal by 10:36 AM
    • disabled automatic health check failover for NLB at 9:36 AM, and re-enabled it at 2:09 PM after EC2 recovered
    • relaxed the EC2 request throttles from 11:23 AM until all EC2 APIs and launches were normal at 1:50 PM
    Action items
    • Disable the DynamoDB DNS Planner and DNS Enactor automation worldwide
    • Fix the race condition and add protections against applying incorrect DNS plans before re-enabling the DNS automation
    • Add a velocity control to NLB that limits how much capacity a single load balancer can remove when health check failures cause availability zone failover
    • Build an additional EC2 test suite that exercises the DWFM recovery workflow at scale
    • Improve throttling in EC2 data propagation systems so incoming work is rate limited by the size of the waiting queue
    Lessons

    A single DNS record that automation can empty is enough to take a widely used regional endpoint off the network, and every service built on it fails in turn. A check made once at the start of a long operation can be stale by the time the operation writes its result. Recovery of the dependency is not recovery of the dependents: systems that lost state during the outage, such as EC2's droplet leases and network propagation backlog, can collapse under their own catch-up work, and container services that rely on new instance launches keep failing to launch and scale until that work is done.

  4. Symptoms

    At 5:00 PM BST on 12 August 2025 a 2i2c engineer declared an incident. While deploying a new cluster called temple and running into NFS issues, the engineer had deleted the prod namespace; the deletion hung, and listing the pods showed many users from a different cluster. The engineer's first message suggested that the kubeconfig had somehow been mutated or corrupted and that some other cluster was being torn down.

    Trigger

    While working around a bug in the NFS deployment process for a new hub, an engineer ran a delete of the prod namespace with the kubeconfig context pointing at the LEAP cluster.

    Root cause
    Component
    Contributing factor
    Detection

    The engineer who ran the deletion noticed when it hung and the pod list showed users of another cluster, and declared the incident at 5:00 PM BST, before the uptime check on leap.2i2c.cloud failed at 5:32 PM.

    Remediation
    • deleted the single remaining user pod in prod so the namespace deletion completed
    • killed the nfs-share-creator job that was blocking the deployment
    • redeployed the prod hub with the updated NFS server IP address
    • deleted the prod ingress during the deployment so that users could not start servers mid-deployment
    Action items
    • Write an incident report
    • Write a short incident response document for the case "I deleted prod, what next?"
    • Upgrade jupyterhub-home-nfs and remove the nfs-share-creator job
    • Add opt-in hardening against nested kubeconfig contexts to the deployer system
    • Change the engineer's shell configuration to show distinct kubeconfig contexts more clearly
    Lessons

    Provisioning persistent storage outside Kubernetes with Terraform meant a deleted namespace cost an hour of downtime and no data. The engineer had no visible cue for which kubeconfig context was active, which turned a workaround on a new cluster into a deletion on a production one. The engineer knew the fix but did not feel confident redeploying without first confirming with the tech lead, in another time zone, that there was no risk of losing persistent data, and reaching the tech lead took time.

  5. Symptoms

    At around 09:33 UTC one of the three control plane nodes of the Kubernetes cluster that hosts Magic Pages went offline. Looking at the node showed that it had run out of memory.

    Trigger

    One of the three control plane nodes ran out of memory and went offline at about 09:33 UTC; the attempts to replace it with hetzner-k3s failed while the cluster's own components were exhausting the Hetzner API rate limit.

    Root cause
    Component
    Contributing factor
    Detection

    The founder found the control plane node offline at about 09:33 UTC. Monitoring alerts about unreachable customer websites started around the time the replacement attempts failed, and about half an hour of investigation identified the exhausted Hetzner API rate limit.

    Remediation
    • powered off all servers of the Kubernetes cluster to stop the API requests so the Hetzner rate limit could recover
    • waited until ratelimit-remaining had built up a buffer before starting recovery
    • restarted the control plane servers
    • started the essential Longhorn components by hand so Longhorn could heal and make storage volumes available
    • restarted the remaining websites by hand
    Action items
    • Monitor the Hetzner API call rate coming from the Kubernetes cluster nodes themselves to get early warning of high usage
    • Get a higher Hetzner API rate limit; Hetzner support was contacted
    • Investigate how to reduce the cluster's reliance on a single API, including alternatives to hetzner-k3s
    • Document and test a procedure for recovering Longhorn after a full cluster shutdown
    Lessons

    The running cluster, not only the deployment tooling, consumed the cloud provider's API quota, and in a failure it consumed it fast enough that the quota never recovered. The default limit of 3600 requests per hour was not enough for failure and recovery scenarios, and API usage from inside the cluster was not monitored. A tool that hides the provider's API errors slows diagnosis. After a full, non-graceful shutdown, Longhorn needed manual intervention to come back, which lengthened the outage.

Check your cluster for this

These 10 cases involve Persistent volumes and stateful sets and Terraform. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause6

Faulty deployment2 cases

  1. IL-0136 A deployment that cleared an internal service's caches at peak traffic sent 20 times the normal load to the Azure OpenAI metadata backend in Sweden Central, and health checks that depended on its database restarted instances in a loop for almost six hours
  2. IL-0086 A deployment meant for a CircleCI test Kubernetes cluster also removed Traefik and Calico resources from the production cluster, taking down the CircleCI UI and runner.circleci.com

Dependency failure2 cases

Organisation
  1. IL-0133 A storm shut down cooling at Nebius's us-central1 data center, and a disk hot-plug bug kept Managed Kubernetes control planes down for hours after power returned
    Nebius2026
  2. IL-0126 The OPT-175B training run restarted more than 40 times in two weeks as cloud GPU nodes failed with ECC errors, replacement nodes came back faulty, and checkpoint downloads hung

Software defect1 case

  1. IL-0150 A latent race condition in DynamoDB's DNS automation left an empty DNS record for dynamodb.us-east-1.amazonaws.com, and the DynamoDB and EC2 launch failures that followed caused EKS, ECS and Fargate container launch failures and cluster scaling delays in us-east-1

Operator error1 case

Organisation
  1. IL-0095 An engineer deleted the prod namespace of the LEAP JupyterHub while believing the kubeconfig pointed at a new cluster, and the hub was down for about an hour
    2i2c2025

Capacity exhaustion1 case

Organisation
  1. IL-0085 A control plane node of Magic Pages' Kubernetes cluster on Hetzner Cloud ran out of memory, the cluster's own calls then used up the Hetzner API rate limit, and all customer websites were down for about 7.5 hours

Configuration change3 cases

  1. IL-0091 Changing the worker node instance type through Terraform recycled all nodes at once and deleted users' production pods together
  2. IL-0109 A retried node rollover on a DFDS EKS cluster set the Auto Scaling group back to 15 instances, and the default termination policy removed every healthy worker node, leaving the cluster with no nodes
    DFDS2023
  3. IL-0009 A duplicated generated name made Argo CD replace the InfluxDB Cloud production Application and delete the whole production environment