Incident Library
Applied filters FactorNo safeguard on destructive changeOrganisationIONOS CloudClear allEvery case under the filters, with no sentence; newest first.
Suggested filters Search, and the values found in your words appear here.

Graph

  • Root cause
  • Component
  • Symptom
  • Contributing factor
  • Case

Cases1 case

1 to 1 of 1

  1. Symptoms

    On 15 January 2026, network services for VMware-based Private Clouds in IONOS Cloud's Berlin location stopped working: customers lost management VPN access and traffic to and from their virtual machines. Inside IONOS, several management interfaces in the Berlin region could no longer be reached.

    Trigger

    During a planned maintenance window to add a new VLAN to the management devices, a human error in the command replaced the existing VLANs on the trunk between the core and management devices instead of adding to them, so only the new VLAN stayed active.

    Root cause
    Component
    Contributing factor
    Remediation
    • Restarted the affected storage services in the final stage of recovery, which caused a brief second outage
    Action items
    • Audit the management device architecture to segment it better (target Q3 2026)
    • Evaluate and implement ways to prevent unintended VLAN changes, such as improved configuration safeguards or automation scripts (target Q1 2026)
Check your cluster for this