Incident Library
Applied filters Root causeOperator errorSymptomNetwork unreachableFactorNo safeguard on destructive changeClear allEvery case under the filters, with no sentence; newest first.
Suggested filters Search, and the values found in your words appear here.

Graph

  • Root cause
  • Component
  • Symptom
  • Contributing factor
  • Case

Cases2 cases

1 to 2 of 2

  1. Symptoms

    On 15 January 2026, network services for VMware-based Private Clouds in IONOS Cloud's Berlin location stopped working: customers lost management VPN access and traffic to and from their virtual machines. Inside IONOS, several management interfaces in the Berlin region could no longer be reached.

    Trigger

    During a planned maintenance window to add a new VLAN to the management devices, a human error in the command replaced the existing VLANs on the trunk between the core and management devices instead of adding to them, so only the new VLAN stayed active.

    Root cause
    Component
    Contributing factor
    Remediation
    • Restarted the affected storage services in the final stage of recovery, which caused a brief second outage
    Action items
    • Audit the management device architecture to segment it better (target Q3 2026)
    • Evaluate and implement ways to prevent unintended VLAN changes, such as improved configuration safeguards or automation scripts (target Q1 2026)
  2. Symptoms

    On 20 September 2024 at 11:24 the Cloud Platform team received high priority Pingdom alerts for services on the live cluster, and from 11:26 teams reported in the #ask channel that services were unavailable. Users reported that services could not be resolved.

    Trigger

    At 11:21 the infrastructure-vpc-live-1 pipeline was unpaused, and a pull request that had been waiting in its queue ran automatically.

    Root cause
    Component
    Contributing factor
    Detection

    High priority Pingdom alerts for live cluster services reached the Cloud Platform team at 11:24, and users reported that services could not be resolved.

    Remediation
    • Ran terraform apply locally to rebuild the subnet route table associations
    Action items
    • Review and update the process for pausing and resuming infrastructure pipelines so every team member knows its implications
    • Find a way to hold queued pull requests while manual infrastructure updates are under way
    • Find ways to isolate the plan and apply tasks of infrastructure pipelines better
Check your cluster for this

These 2 cases involve CI system and Transit gateway or network interconnect. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause1