  1. Symptoms

    At about 16:38 UTC on 17 March 2025, internal alerts fired across multiple Linode data centers because various servers had been unreachable for an extended period. At the same time customers began reporting problems with several products.

    Trigger

    A release of Akamai Compute's internal backend API component was rolling out, and during the rollout the API gave inconsistent responses to the route servers.

    Root cause
    Component
    Contributing factor
    Detection

    Internal alerts fired across multiple data centers showing servers unreachable for an extended period, and customers reported problems with multiple products at the same time.

    Remediation
    • Restarted the route servers in all data centers in phases, starting with the most affected regions
    Action items
    • Hold backend API releases until there is a better way to make sure route data for route servers is contiguous