  1. Symptoms

    Every rolling update of the team's microservices on Amazon EKS, behind an Application Load Balancer, was followed by intermittent 502 and 503 errors for users. A Slack message at 3 a.m. read "배포는 성공했는데, 서비스는 죽었다" (the deployment succeeded, but the service died). Every pod was Ready and Datadog was green while users saw errors.

    Trigger

    A rolling update of a Deployment served through an ALB that registers pod IPs as targets, with no pod readiness gates.

    Root cause
    Component
    Contributing factor
    Detection

    A Slack message at 3 a.m. reported that the deployment had succeeded but the service was down; Datadog dashboards were green at the time.

    Remediation
    • labelled the namespace with elbv2.k8s.aws/pod-readiness-gate-inject=enabled so the AWS Load Balancer Controller injects pod readiness gates and Kubernetes waits for the ALB target to be healthy before deleting old pods
    Lessons

    A pod being Ready in Kubernetes does not mean the load balancer will send it traffic. Without a readiness gate, a rolling update can delete the old pods while the ALB still considers the new targets unhealthy, and dashboards that track pod status stay green during the errors. Making pods wait longer on shutdown reduced the errors but did not fix the start-up gap and made every deployment much slower; the readiness gate ties the pod's Ready state to the ALB's view of the target.

  2. Symptoms

    Within hours of launching the full SmolLM3 pretraining run (3B parameters, 11T tokens, 384 H100 GPUs on 48 nodes), training throughput fell steeply, with repeated sharp drops. The team expected a steady 13,500 to 14,000 tokens per second, and none of the throughput ablations run beforehand on the same 48 nodes had shown drops.

    Trigger

    Launching the full run with the whole ~24 TB dataset on shared WekaFS storage and the real step count for 11T tokens, both far larger than in the ablation runs.

    Root cause
    Component
    Contributing factor
    Detection

    The team watched training throughput in tokens per second and saw it fall within hours of launch; node-monitoring metrics then tied the large fall to spikes in disk read latency.

    Remediation
    • moved the training data from WekaFS to the local NVMe RAID scratch storage on each node
    • copied the dataset to replacement nodes from a healthy node with fpsync, cutting the copy from 3 hours to 1.5 hours
    • kept a spare node with the dataset preloaded in the Slurm reservation to swap in when a node failed
    • reproduced the drops on a single node and with step counts of about 3M and 32k to rule out hardware and isolate the step count
    • replaced nanotron's nanosets dataloader with the TokenizedBytes dataloader copied from the SmolLM2 setup, which removed the drops
    • pre-shuffled the tokenized sequences offline for each epoch with different seeds (about 1 hour) to fix the noisier loss from TokenizedBytes
    Lessons

    Ablations on data subsets and a short step horizon did not exercise either cause: a shared cache-and-evict filesystem near its capacity, and a dataloader index that grows with the step count. Reproducing the drops on one node separated hardware from software, and varying only the step count pointed at the dataloader. The team chose proven replacements over repairs under deadline pressure, taking an existing dataloader instead of fixing nanosets and offline shuffling instead of changing the dataloader, and warns that too many such shortcuts leave a patchwork system that is hard to maintain.

  3. Symptoms

    GPU nodes for an AI video upscaling job were created normally and reached Ready, and then about 10 to 11 minutes later Karpenter treated each one as unhealthy and replaced it. Every new node went the same way, so the GPU pods kept restarting and the upscaling work could not make progress.

    Trigger

    Enabling Karpenter's node auto-repair feature gate (nodeRepair: true) and then running GPU pods on nodes from the Bottlerocket NVIDIA AMI.

    Root cause
    Component
    Contributing factor
    Detection

    The team noticed GPU nodes being replaced repeatedly after running GPU pods, then found the DCGMError message in the node events.

    Remediation
    • Disabled Karpenter node auto-repair by setting the nodeRepair feature gate to false
    Lessons

    Automatic node repair acts on every unhealthy node condition, including AcceleratedHardwareReady, so an image defect that only breaks GPU health monitoring is enough to have every GPU node terminated and recreated in a loop. Before turning on auto-repair, check which conditions it watches and whether the node image reports them correctly. Disabling auto-repair stops the loop at once but is only a temporary measure; installing the missing library or changing the AMI address the cause but cost more on an immutable OS such as Bottlerocket.

  4. Symptoms

    On 16 May 2025, in Neon's Kubernetes cluster in AWS us-east-1, new compute pods were scheduled but could not start and failed with IP allocation errors. Each Neon compute is a Postgres database running in a lightweight virtual machine in its own pod, so without new pods, idle customer databases could not be woken up.

    Trigger

    On 16 May the Neon control plane's periodic job that terminates idle computes started failing. Compute creations continued, and the number of active computes rose from about 5k to about 8.1k within minutes. On 19 May, a follow-up change that set WARM_IP_TARGET back to 1 started the second round of failures.

    Root cause
    Component
    Contributing factor
    Detection

    As cluster-autoscaler added nodes, the team saw IP allocation errors on new pods that were scheduled but could not start. The rate of successful pod starts and VPC subnet metrics were then used to follow the problem.

    Remediation
    • Set WARM_IP_TARGET=1 to release IPs held by nodes without free CPU or memory
    • Fixed the control plane's periodic job so idle computes were terminated again
    • Restarted the aws-node DaemonSet several times, each with a temporary improvement
    • Set WARM_IP_TARGET=0, MINIMUM_IP_TARGET=0 and WARM_ENI_TARGET=0, which let nodes allocate enough IPs and stabilised the cluster
    • On 19 May, set WARM_IP_TARGET back to 0 after setting it to 1 failed again
    • Enlarged the pool of pre-created warm compute pods to absorb failed pod starts
    Action items
    • Open a pull request to AWS CNI to improve how ipamd releases IPs in this situation
    • Follow up with AWS Support about the roughly 100 subnet IPs that were never allocated, for reasons Neon could not explain
    • Change the architecture to support horizontal scaling
    Lessons

    With default settings AWS CNI can keep many IPs on nodes that cannot use them, so the share of subnet IPs assigned to pods does not tell how close the subnet is to running out. WARM_IP_TARGET and WARM_ENI_TARGET follow different logic, a warm IP target of zero switches to the ENI logic, and IPs in cooldown count toward the target, which behaves badly under high pod churn. Changing these settings during an incident without knowing that logic prolonged the outage, and reverting a setting did not bring back the earlier healthy state.

  5. Symptoms

    At 08:41 UTC on 18 February 2025, several Grafana Labs application teams noticed that some of their endpoints were no longer available. The investigation quickly found that the load balancers for those endpoints were gone.

    Trigger

    A change to the merge policy of a Crossplane composition, made so that the default TLS policy of the load balancers could be overridden, was applied to development, staging and production at the same time.

    Root cause
    Component
    Contributing factor
    Detection

    Application teams noticed at 08:41 UTC that some of their endpoints were no longer available.

    Remediation
    • rolled back the Crossplane composition change
    • recreated the affected Kubernetes Services so that Kubernetes recreated their load balancers
    Action items
    • Add a CI check that blocks a deployment to more than one wave, so any exception to the dev, staging, canary, production order is caught
    • Give higher priority to a more sophisticated wave design that was already under discussion
    • Enable deletion protection on the load balancers, one layer below Crossplane
    • Enable deletion protection on other critical cloud provider resources
    • Develop the Crossplane Managed Resources exporter for change validation and visibility, now in beta testing within Platform engineering; simulated against the change that caused this outage, it shows a clear diff
    • Complete and test support for reconfiguring the TLS policy so application teams can deploy it
    Lessons

    A change that looked small and low-risk had a side effect that only a full end-to-end test through Crossplane and the cloud provider's load balancer controller would have shown; seeing the intended override work was not that test. Staged rollout and blast-radius limits that exist only as process can be skipped, so Grafana Labs moved to enforce waves in CI and to add deletion protection on the load balancers themselves, beneath the Crossplane layer.

Check your cluster for this

These 35 cases involve Telemetry agent and Application database. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause10

Configuration change9 cases

  1. IL-0179 With DEBUG logging and synchronous log output, a high-traffic service filled the 64 KB stdout pipe, so request threads blocked in write() while holding database connections and HikariCP ran dry, failing requests in 30-second bursts
  2. IL-0063 VPN outage after recreating a Redis StatefulSet restarted the whole Redis cluster without readiness checks
  3. IL-0192 A Crossplane composition merge-policy change for a TLS policy update switched Kubernetes Services from LoadBalancer to ClusterIP and deleted the load balancers behind about 25% of Grafana Cloud services
  4. IL-0177 WebSocket connections to LINE's messaging-hub on Kubernetes dropped all at once whenever another service's change reloaded a shared HAProxy L7 load balancer, and the reconnect wave overloaded a token API and filled nf_conntrack on Nginx
    LINE+2022
  5. IL-0209 A too-high HPA CPU target kept GitLab.com web pods from scaling up as traffic moved from VMs to Kubernetes, breaching the web latency SLO for 15 minutes
    GitLab2021
  6. IL-0105 Replacing the AWS VPC CNI during a Terraform refactoring detached the ALB target groups, and every service in the Kubernetes cluster returned 503
    DFDS2021
  7. IL-0108 An Alcide admission controller applied to the production cluster during a workshop made create and update requests on Deployments time out
    DFDS2020
  8. IL-0061 A Terraform pull request merged out of order deleted a production GKE cluster, and recreating it deleted a second one
  9. IL-0066 Broken ConfigMap change lay dormant for weeks, then took down Pusher's edge proxy when a cluster upgrade replaced its pods
    Pusher2019

Software defect8 cases

  1. IL-0058 Argo CD deleted namespaces shared by several applications, leaving about 97 applications stuck Missing and OutOfSync
  2. IL-0171 Karpenter node auto-repair replaced EKS GPU nodes about 10 minutes after they became Ready, in a loop, because the Bottlerocket NVIDIA AMI lacked libdcgm.so and set AcceleratedHardwareReady to False
    Inflab2025
  3. IL-0029 Slow user-facing services from CPU throttling on containers that used far less CPU than their limit
    Buffer2020
  4. IL-0196 Adding a second Redis replica and lowering memory limits in one RedisFailover change restarted the only Redis pod that held data, and Sentinel promoted the empty new replica, erasing the data
    Palark2020
  5. IL-0062 Intermittent 502 errors behind a GKE Ingress because pods shut down before the load balancer stopped sending them traffic
  6. IL-0011 HAProxy ingress piled requests onto the same pods because a Go template visited the backend map in sorted pod IP order
  7. IL-0050 Pods on Kubernetes failed to resolve an external Redis hostname because of ndots:5, the musl resolver in Alpine images, and Netty's DNS resolver
  8. IL-0051 A third-party log shipping client leaked file descriptors with every new container until nodes failed with too many open files

Breaking change in an upgrade1 case

Organisation
  1. IL-0097 A cluster autoscaler version bump was incompatible with the one cluster still on Kubernetes 1.33, so no scale-up events fired and new nodes were not created
    2i2c2026

Faulty deployment3 cases

  1. IL-0160 A repaired legacy GPU monitoring script sent a firmware query that triggers a race condition in the GPU System Processor of NVIDIA RTX 4000 Ada GPUs, locking up GPU Linodes and LKE worker nodes in several regions
    Linode2026
  2. IL-0188 Rolling updates on EKS returned 502 errors for about 30 seconds because Kubernetes deleted old pods as soon as new pods passed readiness, before the ALB had marked the new pod targets healthy
  3. IL-0034 A crashing stats agent sidecar marked every pod unready and the service mesh pulled all services out of traffic
    Airbnb2019

Capacity exhaustion6 cases

  1. IL-0129 Throughput of the 384-GPU SmolLM3 pretraining run collapsed because shared WekaFS storage evicted dataset shards to S3, then kept dropping on local NVMe because the nanotron dataloader built an index that grew with the step count
  2. IL-0006 VPC subnets ran out of IP addresses because the AWS VPC CNI kept IPs on full nodes, and WARM_IP_TARGET changes then blocked pod starts after every pod deletion
    Neon2025
  3. IL-0094 Student pods filled the shared nodes of a JupyterHub cluster and starved the hub's core pods, freezing the hub
    2i2c2020
  4. IL-0064 CPU-heavy pods packed onto one Google Cloud node drove it to kernel panics, and the crash moved from node to node until the site was down
  5. IL-0075 Kubernetes API servers pegged on CPU when the cluster grew to about 290 nodes, traced to Datadog agents polling the API
  6. IL-0036 A reindex Job that kept failing exhausted one node after another until the whole cluster was down

Dependency failure1 case

Organisation
  1. IL-0025 Failed boots, InfiniBand link flapping, NCCL hangs and throughput sags while bringing up a 4,088-GPU H100 training cluster
    Imbue2024

DNS or network fault2 cases

  1. IL-0083 Intermittent 5xx errors in a multi-tenant Kubernetes cluster came from internal DNS: the node-local dnsmasq hit its 150 concurrent query limit, did not cache cluster.local answers, and ndots search lookups flooded CoreDNS
  2. IL-0056 Calls from EKS pods to services behind an NLB in another VPC failed intermittently because the AWS VPC CNI did source NAT on the node

unknown1 case

Organisation
  1. IL-0087 After a cold reboot of RKE2 nodes, pods could not get IP addresses because Multus could not reach the Kubernetes API, and further reboots spread the failure to every node

Operator error2 cases

Organisation
  1. IL-0197 Moving a three-node Elasticsearch StatefulSet to new persistent volumes split the cluster in two, because the Helm chart hardcoded cluster.initial_master_nodes to elasticsearch-0
    Palark2021
  2. IL-0054 All ingress traffic lost while draining a GKE node pool because the load balancer only targeted new nodes without ingress-nginx pods

Cloud provider outage2 cases

  1. IL-0172 An AWS Tokyo data centre cooling failure took down 6 of 60 CockroachDB nodes on Kubernetes within 22 minutes, and ranges lost quorum because the Helm-deployed cluster had no availability zone locality configured
  2. IL-0193 A GCP persistent disk degradation took down a Cassandra StatefulSet whose OrderedReady policy blocked recovery, and Metrictank could not reconnect to the recreated pods, causing a 23-hour Graphite query outage