  1. Symptoms

    On a Tuesday morning a developer reported that some production logs were missing. Only the logs from a single node were gone; the other nodes kept shipping normally through fluent-bit, the log shipper the team had run for more than three years.

    Root cause
    Component
    Contributing factor
    Detection

    A developer reported missing production logs; no alert fired because fluent-bit's metrics showed no errors.

    Remediation
    • added CPU to the Elasticsearch virtual machines, which cleared the write queue rejections
    • rolled out Fluentd one node at a time, using node affinity to place Fluentd and anti-affinity to remove fluent-bit
    • lowered Fluentd's flush_thread_count to 1 and set flush_interval to 5 seconds so the backlog of old logs did not overflow the buffer
    • enabled Fluentd's Position DB so already-ingested data was skipped
    Action items
    • Build monitoring for Fluentd on its Prometheus integration, including a throughput alert with separate day and night thresholds or a black-box log check
    Lessons

    A log shipper can fail without an error message and with metrics that simply stop moving, so error-based alerts never fire; throughput alerts or end-to-end checks can catch it. Open source software can break in ways nobody expects, and sometimes the way out is to switch to a different shipper fast, node by node. A new shipper that starts from scratch replays every old log on the node and needs to be slowed down.

  2. Symptoms

    At 18:27 on 21 September 2020 the Cloud Platform team detected that some services running on the live-1 production cluster had gone down, and some users could not reach them. The incident was declared at 18:40.

    Trigger

    A script for deleting a test cluster was triggered while the kube context was pointing at the live-1 production cluster instead of the test cluster.

    Root cause
    Component
    Contributing factor
    Detection

    The first detection was at 18:27, and the incident was declared 13 minutes later, at 18:40.

    Remediation
    • restored the default ingress controller together with external-dns and kiam, which it depends on
    • corrected the owner field in the Formbuilder Route 53 TXT records so external-dns pointed their A records at the new NLB
    • restored the remaining components with a targeted apply
    • ran the apply pipeline to restore all certificates, ServiceMonitors and Prometheus rules from the environment repository
  3. Symptoms

    One Monday morning the author opened the Prometheus dashboard to check a Kubernetes cluster for alerts and could not reach it. The Prometheus pod was in CrashLoopBackOff: kubectl get pods showed it 1/2 ready with 950 restarts over 3d20h on worker3.

    Trigger

    After start, the Prometheus time series count rose to 2,162,256 within five minutes and its memory use filled the 8GB host.

    Root cause
    Component
    Contributing factor
    Detection

    The author found it on a Monday morning when the Prometheus dashboard, opened to check the cluster for alerts, could not be reached.

    Remediation
    • removed most of the unnecessary settings from the Prometheus ConfigMap, after which the container stopped crashing
    Action items
    • Set appropriate resource requests and limits on the Prometheus pod
    • Reduce unneeded metrics by adjusting scrape targets or scrape interval
    • Estimate Prometheus memory needs, provide dedicated hosts with a node label such as deploy-topology: Prometheus, and pin the Prometheus pod to them with a nodeSelector
    Lessons

    Exit code 137 together with an OOM event in the kubelet log means the kernel killed the container, not kubelet. Under node memory pressure the kernel kills the process with the highest score, and kubelet derives each container's oom_score_adj from the pod's QoS class: a container without a memory request in a pod where another container has one ends up Burstable with a score near 1000, so it is killed first. In a large cluster, Prometheus memory needs to be estimated from the expected series count and requested explicitly.

  4. Symptoms

    Dex, the OIDC proxy that handled Kubernetes authentication, stored its data in the Kubernetes API (storage type kubernetes, inCluster: true) and had built up a huge number of AuthRequest objects. Listing all AuthRequests timed out, and without the list they could not be deleted.

    Trigger

    The dex namespace was deleted so that Kubernetes would clean up the accumulated AuthRequest objects itself.

    Root cause
    Component
    Contributing factor
    Detection

    The speaker says he had got hints of the problem earlier. While the masters were down, plenty of alerts arrived in Slack, but monitoring could not be reached because authentication and port-forwarding no longer worked.

    Remediation
    • removed the kubernetes finalizer from the dex namespace by calling the API directly (kill-kube-ns)
    • deployed Dex to a new namespace with sane defaults
    Lessons

    Dex with Kubernetes as its storage keeps every AuthRequest as an API object, and with a long TTL they pile up until the API cannot list them. Deleting a namespace that holds that many objects makes Kubernetes list them in a loop and can overload the masters. Monitoring that is reached through cluster authentication is lost when authentication is what broke.

  5. Symptoms

    The NU.nl development team got reports that several services on one of its Kubernetes clusters behaved erratically: occasional error pages, slow responses and timeouts. The affected services were mostly internal tools and dashboards.

    Trigger

    A new ElastAlert rule, deployed shortly before from the command line, that fired if the Cloudfront-* Elasticsearch indexes stopped receiving documents; those indexes take a few million requests per hour, and the rule made ElastAlert's memory grow without bound.

    Root cause
    Component
    Contributing factor
    Detection

    Users reported error pages, slow responses and timeouts from several services; no alert fired.

    Remediation
    • terminated the NotReady nodes one by one so the auto-scaling group replaced them (the new nodes also went NotReady, but Prometheus and Grafana landed on a stable node)
    • found the ElastAlert pods' memory growth on the Grafana pod memory dashboard
    • fixed the ElastAlert problem that caused the memory growth
    Action items
    • Define alerts on resource usage such as CPU, memory and disk space
    • Keep researching an alerting strategy that combines Elasticsearch, Prometheus Alertmanager and New Relic
    • Consider exporting metrics out of the cluster and running Grafana outside it, on EC2 or a separate Kubernetes cluster
    • Either visualise the important metrics in the ELK stack or make Prometheus and Grafana more available, and improve the metrics strategy
    • Set resource limits for ElastAlert through the Helm values
    • Configure namespaces with default memory requests and limits
    • Isolate customer-facing workloads from build, logging and monitoring workloads (a dedicated node group, or later a separate tools cluster)
    • Deploy everything through automation such as Jenkins pipelines, and consider a GitOps approach
    • Deploy through a pipeline that includes a smoke test step
    • Make Kubernetes and cloud infrastructure work part of the team's sprints, picked up by all team members while pairing with more experienced members, and hold workshops that go deep into specific topics
    Lessons

    Fixing the root cause covers only a small part of what an incident can teach; the chain of smaller failures around it is where most of the learning is. A pod without a memory limit can take whole nodes down, so limits need defaults at the namespace level. Monitoring that runs inside the cluster it watches goes blind with it. Changes installed by hand from the command line leave the rest of the team without a record of what changed.

Check your cluster for this

These 19 cases involve Prometheus and Container memory limit. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause7

Dependency failure1 case

Organisation
  1. IL-0133 A storm shut down cooling at Nebius's us-central1 data center, and a disk hot-plug bug kept Managed Kubernetes control planes down for hours after power returned
    Nebius2026

Software defect2 cases

  1. IL-0138 A failed Nvidia driver build left broken kernel packages on the only Kubernetes master node, which hit a kernel panic on reboot after a power outage and took the homelab cluster down for six days
  2. IL-0041 fluent-bit silently stopped shipping application logs from one node to Elasticsearch

Capacity exhaustion10 cases

  1. IL-0042 Application logs stopped reaching Elasticsearch and OpenSearch for hours and were lost when OpenSearch ran out of disk space
  2. IL-0044 Prometheus OOMKilled in a loop while replaying its write-ahead log after a kube-prometheus-stack upgrade
  3. IL-0046 Prometheus restarted again and again because its WAL replay took longer than the startup probe allowed
  4. IL-0110 A Grafana Agent pod's high memory use and crash-looping Hangfire pods drove a Kubernetes node into system OOM and NotReady, twice in one day
    DFDS2024
  5. IL-0169 The Scaleway Kubernetes API in FR-PAR ran out of memory under simultaneous deployments, and because it also handled node authentication, Kapsule and Kosmos nodes went NotReady
  6. IL-0043 Application logs missing in Kibana after a newer Fluent Bit version changed its chunk drop strategy
  7. IL-0016 Prometheus on the live cluster ran out of memory and was OOMKilled, and the monitoring node it ran on went NotReady
  8. IL-0176 Prometheus in a 235-node Kubernetes cluster crash-looped because over two million series exhausted host memory and the kernel OOM killer chose it first, as Burstable QoS gave it oom_score_adj 999
    LINE2020
  9. IL-0076 Kubernetes masters went down after Dex filled etcd with AuthRequest objects and deleting its namespace started an endless list-and-timeout loop
  10. IL-0001 Cluster-wide DNS outage after CoreDNS pods were OOM-killed again and again under a burst of DNS queries

unknown1 case

Component
Contributing factor
–
  1. IL-0045 Prometheus on the live cluster restarted several times after readiness probe failures, leaving gaps in metrics

Breaking change in an upgrade2 cases

  1. IL-0060 Kubernetes 1.24 upgrade removed the master node label that Calico route reflectors selected on, dropping all pod routes and taking Reddit down for 314 minutes
    Reddit2023
  2. IL-0144 A systemd security update installed by unattended-upgrades lost the DNS configuration of Ubuntu 18.04 VMs, so AKS kubelets could not resolve registry names and pods failed with ImagePullBackOff

Configuration change2 cases

Organisation
  1. IL-0109 A retried node rollover on a DFDS EKS cluster set the Auto Scaling group back to 15 instances, and the default termination policy removed every healthy worker node, leaving the cluster with no nodes
    DFDS2023
  2. IL-0035 Worker nodes went NotReady after a new ElastAlert rule without memory limits used up node memory
    NU.nl2019

Operator error1 case

  1. IL-0089 A test cluster deletion script run with the kube context pointing at the live-1 production cluster deleted its ingress controller, monitoring, logging, cert-manager, kiam and external-dns