Incident Library
  • Root cause
  • Component
  • Symptom
  • Contributing factor
  • Case

Cases20 cases

16 to 20 of 20

  1. Symptoms

    On a Saturday at 5:12 pm, Blue Matador's own monitoring raised a SystemOOM event for one node in the production Kubernetes cluster. Four minutes later a second warning reported a low EBS Burst Balance on that node's root volume. CloudWatch data showed the burst balance had actually bottomed out at 5:02 pm, before the memory event; the warning arrived late because EBS metrics lag 10 to 15 minutes.

    Trigger

    Memory use of the fluentd-sumologic log shipper pods grew until the node ran out of memory; log volume in Sumo Logic had been steady, so a burst of logs was not the cause.

    Root cause
    Component
    Contributing factor
    Detection

    Blue Matador's own monitoring product alerted on the SystemOOM event, followed minutes later by a low EBS Burst Balance warning for the same node.

    Remediation
    • restarted all fluentd-sumologic pods so they started with low memory
    • set RUBY_GC_HEAP_OLDOBJECT_LIMIT_FACTOR to 0.9 on the fluentd-sumologic pods
    • added memory requests of 128Mi and limits of 1024Mi, and CPU requests of 100m and limits of 250m, to the fluentd-sumologic pods
    Action items
    • Apply default resource limits and resource quotas so that every pod runs with requests and limits
    Lessons

    When checking for restarted pods, look in every namespace, not only the application one. Set resource requests and limits on every pod, third-party ones in particular, so that one workload cannot exhaust a node. Investigate side signals such as the disk I/O spike while the logs still exist.

  2. Symptoms

    On a Sunday, a team using one of Skyscanner's Kubernetes clusters manually paged the out-of-hours Kubernetes support because their service showed elevated latency, worst at the p90 and maximum levels.

    Trigger

    Upgrading the HAProxy ingress controller to v0.6 and going back from Service virtual IPs to individual pod IPs as backends, on the understanding that the sort-backends flag introduced in v0.5, false by default, meant backends were randomly shuffled.

    Root cause
    Component
    Contributing factor
    Detection

    A cluster user manually paged the out-of-hours Kubernetes support about elevated latency; Prometheus queries then showed the uneven request distribution across pods.

    Remediation
    • switched the affected service from pod IPs back to the Service virtual IP through a config change in the internal deployment tool Slingshot
    • patched the controller to keep each backend's servers in an insertion-ordered slice and changed the template to iterate over that slice
    • tested the patch in sandbox clusters and rolled it out to the production clusters
    Action items
    • Run the internal controller patch in production and return to pod IPs as the default backends
    • Raise the problem upstream with a GitHub issue and pull request
    • Test changes to cluster components against the specific behaviour and conditions that matter
    Lessons

    The team already knew that sorted backends cause hot-podding and still did not test the new flag well enough to see that it did not work; changes to cluster components need tests aimed at the exact behaviour that matters, under conditions like production. A keyword can behave differently in different parts of a language: range over a map is unordered in Go code but sorted in text/template. A small cluster component can do outsized harm to every user of the cluster and, in the end, to customers.

  3. Symptoms

    The NU.nl development team got reports that several services on one of its Kubernetes clusters behaved erratically: occasional error pages, slow responses and timeouts. The affected services were mostly internal tools and dashboards.

    Trigger

    A new ElastAlert rule, deployed shortly before from the command line, that fired if the Cloudfront-* Elasticsearch indexes stopped receiving documents; those indexes take a few million requests per hour, and the rule made ElastAlert's memory grow without bound.

    Root cause
    Component
    Contributing factor
    Detection

    Users reported error pages, slow responses and timeouts from several services; no alert fired.

    Remediation
    • terminated the NotReady nodes one by one so the auto-scaling group replaced them (the new nodes also went NotReady, but Prometheus and Grafana landed on a stable node)
    • found the ElastAlert pods' memory growth on the Grafana pod memory dashboard
    • fixed the ElastAlert problem that caused the memory growth
    Action items
    • Define alerts on resource usage such as CPU, memory and disk space
    • Keep researching an alerting strategy that combines Elasticsearch, Prometheus Alertmanager and New Relic
    • Consider exporting metrics out of the cluster and running Grafana outside it, on EC2 or a separate Kubernetes cluster
    • Either visualise the important metrics in the ELK stack or make Prometheus and Grafana more available, and improve the metrics strategy
    • Set resource limits for ElastAlert through the Helm values
    • Configure namespaces with default memory requests and limits
    • Isolate customer-facing workloads from build, logging and monitoring workloads (a dedicated node group, or later a separate tools cluster)
    • Deploy everything through automation such as Jenkins pipelines, and consider a GitOps approach
    • Deploy through a pipeline that includes a smoke test step
    • Make Kubernetes and cloud infrastructure work part of the team's sprints, picked up by all team members while pairing with more experienced members, and hold workshops that go deep into specific topics
    Lessons

    Fixing the root cause covers only a small part of what an incident can teach; the chain of smaller failures around it is where most of the learning is. A pod without a memory limit can take whole nodes down, so limits need defaults at the namespace level. Monitoring that runs inside the cluster it watches goes blind with it. Changes installed by hand from the command line leave the rest of the team without a record of what changed.

  4. Symptoms

    Customers of the Zalando Fashion Store got a high rate of errors on all web product pages and outfit pages for more than an hour. The errors came from the main data aggregation layer service, which runs in one of Zalando's Kubernetes clusters.

    Trigger

    Calls from the aggregation layer to a single, not very important downstream service started timing out. The aggregation layer returned 404s for them, clients retried, and the resulting spike in requests became a spike in DNS queries to CoreDNS.

    Root cause
    Component
    Contributing factor
    Detection

    The on-call engineer for the aggregation layer phoned the on-call Kubernetes engineer. Automatic paging did not happen because the cluster's monitoring and alerting ran inside the cluster and failed along with DNS. The Kubernetes engineer then saw that the CoreDNS pods were being OOM-killed.

    Remediation
    • Raised the CoreDNS memory requests and limits by hand from 100Mi to 2000Mi
    Action items
    • Introduce a more resilient DNS setup: CoreDNS fronted by dnsmasq on every node
    • Improve high-level alerting from outside the clusters, so that a cluster problem is known before or at the same time as applications are affected
    • Improve incident response processes and tooling so that any on-call engineer can escalate directly to other teams when automatic paging fails, for example through a chat bot
    Lessons

    The Kubernetes DNS setup was far from resilient enough: a single application could take down DNS for everything in the cluster. The blast radius of one application sending more DNS queries should be limited to one node at most, ideally to single pods. Known Kubernetes DNS problems, such as Linux kernel races in conntrack handling and the ndots 5 problem, were familiar to the team and partly mitigated, but their combined effect on the DNS infrastructure was worse than the team had understood. Monitoring that runs inside the cluster was not robust enough: when the cluster's DNS broke, it could not page anyone, and recovery took longer than it should have.

  5. Symptoms

    Customers were affected, and Zalando's IAM service answered requests with HTTP 404. The talk shows this on slides titled "Customer impact" and "IAM returning 404", followed by a slide on the number of pods in the cluster.

    Trigger

    A CronJob (apiVersion batch/v2alpha1, schedule "*/15 9-19 * * Mon-Fri") whose concurrencyPolicy: Forbid and job history limits sat inside the pod template spec instead of the CronJob spec. The talk shows it right after the slides on the number of pods and the API server being OOM-killed, and the lessons add a quota on the number of pods.

    Root cause
    Component
    Contributing factor
    Remediation
    • fixed the CronJob manifest: moved concurrencyPolicy: Forbid and the job history limits to the CronJob spec, added activeDeadlineSeconds: 120 and changed the schedule to "7 8-18 * * Mon-Fri"
    Action items
    • Make the ingress stay healthy during API server problems
    • Make the ingress keep the last known set of routes
    • Use a ResourceQuota on the number of pods (the example sets pods: "1500")
    Lessons

    An AWS ALB routes traffic to all hosts when all hosts report unhealthy, so the ingress should stay healthy during API server problems. An ingress controller that reads routes from the API server should keep its last known set of routes. Use a quota for the number of pods.

Check your cluster for this

These 20 cases involve Container memory limit and CoreDNS. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause4

Capacity exhaustion13 cases

  1. IL-0102 CoreDNS pods on a production EKS cluster ran out of memory under a burst of new pods, endpoints and nodes, taking down the Buildkite web UI, APIs and job dispatch
  2. IL-0027 All CoreDNS pods landed on one node, the node ran out of memory, and DNS for the whole service went down
  3. IL-0044 Prometheus OOMKilled in a loop while replaying its write-ahead log after a kube-prometheus-stack upgrade
  4. IL-0110 A Grafana Agent pod's high memory use and crash-looping Hangfire pods drove a Kubernetes node into system OOM and NotReady, twice in one day
    DFDS2024
  5. IL-0168 Simultaneous cluster auto-upgrades overloaded Scaleway's Kubernetes API, and a node authentication retry loop kept Kapsule and Kosmos nodes NotReady in FR-PAR
  6. IL-0169 The Scaleway Kubernetes API in FR-PAR ran out of memory under simultaneous deployments, and because it also handled node authentication, Kapsule and Kosmos nodes went NotReady
  7. IL-0016 Prometheus on the live cluster ran out of memory and was OOMKilled, and the monitoring node it ran on went NotReady
  8. IL-0195 The kube-apiservers of a cluster with more than 200 nodes ran out of memory and crashed one after another under mass LIST requests from Cilium agents
    Palark2023
  9. IL-0206 Consul agents in GitLab.com's GKE pods were repeatedly OOM-killed, so the Rails pods lost database replica discovery and sent every query to the primary
    GitLab2022
  10. IL-0176 Prometheus in a 235-node Kubernetes cluster crash-looped because over two million series exhausted host memory and the kernel OOM killer chose it first, as Burstable QoS gave it oom_score_adj 999
    LINE2020
  11. IL-0026 Kubernetes nodes hit SystemOOM because fluentd-sumologic log shipper pods had no memory limits
  12. IL-0001 Cluster-wide DNS outage after CoreDNS pods were OOM-killed again and again under a burst of DNS queries
  13. IL-0031 Kubernetes API server OOM-killed, leaving the Skipper ingress without routes; the talk points to a misconfigured CronJob manifest

Configuration change4 cases

  1. IL-0063 VPN outage after recreating a Redis StatefulSet restarted the whole Redis cluster without readiness checks
  2. IL-0191 A label selector accidentally added to the Loki distributor Service matched only the new pods of a rollout, which took all write traffic, were OOM-killed and stalled the rollout
  3. IL-0004 A new default pod priority let a new Cortex cluster preempt every production ingester in a cascade, taking Grafana Cloud Hosted Prometheus down
  4. IL-0035 Worker nodes went NotReady after a new ElastAlert rule without memory limits used up node memory
    NU.nl2019

Software defect2 cases

  1. IL-0104 After a CoreDNS pod was OOMKilled, the talk names three causes: Istio's aggressive DNS cache refresh on one reused client port, kube-proxy not cleaning up conntrack entries of terminated pods, and the 2-minute UDP conntrack timeout
  2. IL-0011 HAProxy ingress piled requests onto the same pods because a Go template visited the backend map in sorted pod IP order

DNS or network fault1 case

Organisation
  1. IL-0199 A non-essential container exceeding its memory limit made GitHub's production pods unavailable, and their restarts failed because a DNS maintenance change had left the clusters unable to reach the image registry
    GitHub2020