Incident Library
  • Root cause
  • Component
  • Symptom
  • Contributing factor
  • Case

Cases7 cases

4 to 7 of 7

  1. Symptoms

    From 17 October 2024, packets through the vSwitch that joined Namespace's bare metal machines at one provider in the fra3 region were dropped at random. Retries in TCP, QUIC and the Namespace control plane hid most of it, but the SLO error budget for latency targets on key interactions began to burn.

    Trigger

    Random packet drops on the bare metal provider's vSwitch from 17 October 2024; for the second outage, a rate of Kubernetes changes that the slow NVMe on one control plane node could no longer keep up with.

    Root cause
    Component
    Contributing factor
    Detection

    SLO-based monitoring of latency targets showed the error budget burning while retries hid the individual packet drops.

    Remediation
    • diverted all customer traffic from fra3 to other regions
    • connected each provider machine to the zrh1 cluster over Wireguard instead of the vSwitch
    • repaved every fra3 machine with a new identity, certificates and encryption-at-rest keys, dropping regional caches to recover faster
    • cloned existing datasets in a more distributed way to speed up repaving the machines
    • added machines back to the new region in batches and returned the region to the compute pool
    • redirected workloads away from zrh1 during the second outage
    • cloned the failing control plane node's key state to a higher-capacity node that took over its role and IP address
    Action items
    • Credit all instances that ran during the outages back to customers
    • Build up backup regions and solutions so a similar event has options that do not affect customers
    Lessons

    Running hot with a delayed hardware delivery left no room to take a region out, so fixing a provider network fault turned into a global capacity shortage. After one outage the team was anchored on its cause and first looked for network problems in the second outage, which had a different cause: a control plane node whose disk could not keep up with the Kubernetes change rate.

  2. Symptoms

    One Monday morning the author opened the Prometheus dashboard to check a Kubernetes cluster for alerts and could not reach it. The Prometheus pod was in CrashLoopBackOff: kubectl get pods showed it 1/2 ready with 950 restarts over 3d20h on worker3.

    Trigger

    After start, the Prometheus time series count rose to 2,162,256 within five minutes and its memory use filled the 8GB host.

    Root cause
    Component
    Contributing factor
    Detection

    The author found it on a Monday morning when the Prometheus dashboard, opened to check the cluster for alerts, could not be reached.

    Remediation
    • removed most of the unnecessary settings from the Prometheus ConfigMap, after which the container stopped crashing
    Action items
    • Set appropriate resource requests and limits on the Prometheus pod
    • Reduce unneeded metrics by adjusting scrape targets or scrape interval
    • Estimate Prometheus memory needs, provide dedicated hosts with a node label such as deploy-topology: Prometheus, and pin the Prometheus pod to them with a nodeSelector
    Lessons

    Exit code 137 together with an OOM event in the kubelet log means the kernel killed the container, not kubelet. Under node memory pressure the kernel kills the process with the highest score, and kubelet derives each container's oom_score_adj from the pod's QoS class: a container without a memory request in a pod where another container has one ends up Burstable with a score near 1000, so it is killed first. In a large cluster, Prometheus memory needs to be estimated from the expected series count and requested explicitly.

  3. Symptoms

    Shortly after a round of changes, loveholidays saw connectivity problems and raised error rates on its aggregation service. The service is a proxy between two other services of more than 100 instances each, handles over 10,000 requests per second continuously and can spike to four times that.

    Trigger

    Three changes together: a change in service architecture, halving the RAM of the nodes that run the aggregation service, and sharding a downstream service, which doubled the number of connections to track.

    Root cause
    Component
    Contributing factor
    Detection

    Rising error rates and climbing connection reset errors in HAProxy, then node_exporter conntrack metrics compared with their limit.

    Remediation
    • moved the aggregation service to nodes with more RAM
    • limited the number of aggregation service pods per node
    Action items
    • Alert when conntrack table use goes above 75%, with (node_nf_conntrack_entries / on (pod) node_nf_conntrack_entries_limit / on (pod) group_right kube_pod_info) > 0.75
    Lessons

    The conntrack limit is tied to node memory, so resizing a node pool silently resizes the connection table, and on GKE the ratio did not match the commonly cited formula. A high-traffic proxy on small nodes can exhaust it, and the symptoms are connection resets and timeouts, so conntrack use needs its own metric and alert.

  4. Symptoms

    After Civis released its new script infrastructure on Kubernetes internally in September 2018, developers reported that kubectl commands were slow, and users intermittently could not start notebooks and services.

    Trigger

    Migrating clients' Python, R and container scripts from the in-house Bocce system to Kubernetes (the project called Croquet) pushed the cluster to about 290 EC2 instances under a large script load.

    Root cause
    Component
    Contributing factor
    Detection

    Developer reports of slow kubectl commands and user reports of notebooks and services failing to start, then high CPU on the master nodes.

    Remediation
    • moved internal users back to the old Bocce infrastructure
    • resized the three master nodes from m4.large to m4.4xlarge
    • changed the Datadog setup so per-node agents no longer polled the API server for service metadata
    • raised max-requests-inflight for non-mutating requests from 400 to 1200
    • grew the etcd EBS volumes from 20 to 100 GB (100 to 300 IOPS)
    • switched client scripts from the ClusterFirst DNS policy to Default
    Action items
    • Upgrade etcd from 2.2.1 to 3.x once Kops supports a safe migration
    • Solve the in-cluster DNS timeouts so client scripts can talk to other workloads in the cluster
    Lessons

    Kubernetes can reach thousands of nodes only after tuning, and third-party DaemonSets are a common cause of control plane load: an agent on every node that polls or watches the API server multiplies with the cluster size. Datadog, kube2iam and the fluentd metadata filter all showed this. A small configuration change often fixes it, but finding it took load testing and the API server access logs.

Check your cluster for this

These 7 cases involve Kubernetes API server and VPC subnet or pod address range. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause2

Capacity exhaustion6 cases

  1. IL-0067 Redis filled its persistent volume, corrupted its append-only file and crash-looped on every restart
  2. IL-0006 VPC subnets ran out of IP addresses because the AWS VPC CNI kept IPs on full nodes, and WARM_IP_TARGET changes then blocked pod starts after every pod deletion
    Neon2025
  3. IL-0007 The AWS VPC CNI could not assign IP addresses to pods as an EKS cluster ran out of IPv4 space
  4. IL-0176 Prometheus in a 235-node Kubernetes cluster crash-looped because over two million series exhausted host memory and the kernel OOM killer chose it first, as Burstable QoS gave it oom_score_adj 999
    LINE2020
  5. IL-0013 The conntrack table filled up on downsized GKE nodes and a high-traffic aggregation proxy saw climbing connection resets
  6. IL-0075 Kubernetes API servers pegged on CPU when the cluster grew to about 290 nodes, traced to Datadog agents polling the API

Cloud provider outage1 case

Organisation
  1. IL-0084 Packet drops on a bare metal provider's vSwitch forced Namespace to rebuild its fra3 region and left global capacity short, and the next day slow NVMe writes on a control plane node drove the Kubernetes API server to very high CPU