Incident Library
  • Root cause
  • Component
  • Symptom
  • Contributing factor
  • Case

Cases2 cases

1 to 2 of 2

  1. Symptoms

    At about 20:00 on a weekday, one of DeNA's largest sites reported that terminals of a customer-facing system could not communicate and business was suffering. The network group's monitoring had raised no alert.

    Trigger

    During a routine change on 15 Cisco Catalyst 2960L access switches at the site, which tidied descriptions, added VLAN definitions and added allowed VLANs on trunk ports, `no switchport trunk allowed vlan` was applied to GigabitEthernet0/15 of switch SW3, only one of the two physical ports in the LACP bundle between SW3 and SW2.

    Root cause
    Component
    Contributing factor
    Detection

    The site reported the problem at about 20:00; no monitoring alert fired, because the affected port had no interface monitoring and LACP monitoring had been removed by an earlier monitoring change.

    Remediation
    • Rolled back the switch changes without knowing the cause; service recovered when the interface setting of one switch was restored
    • Found the faulty port and confirmed there was no other impact, completing the first response at about 22:00
    Action items
    • Fix the missing interface and LACP monitoring
    • Require a review for every monitoring change
    • Block merges to the alert rule repository without a reviewer's approval
    • Enable automatic AI review on pull requests
    • Announce every network change in advance, however minor
    • Agree the work date with the site's managers and avoid the site's event days
    • Prepare rollback procedures for high-impact maintenance and for work on several devices at once
    Lessons

    Any change can cause an outage, through a mistake, an unexpected event or a bug, so changes need to be scheduled with a maintenance window agreed in advance. A change on a downstream access switch can affect the whole site. Changing many devices at once made it slow both to find the faulty device and to roll back, and the parts that can be prevented by mechanisms rather than by people's care, such as reviews and monitoring, should be enforced that way.

  2. Symptoms

    On 15 January 2026, network services for VMware-based Private Clouds in IONOS Cloud's Berlin location stopped working: customers lost management VPN access and traffic to and from their virtual machines. Inside IONOS, several management interfaces in the Berlin region could no longer be reached.

    Trigger

    During a planned maintenance window to add a new VLAN to the management devices, a human error in the command replaced the existing VLANs on the trunk between the core and management devices instead of adding to them, so only the new VLAN stayed active.

    Root cause
    Component
    Contributing factor
    Remediation
    • Restarted the affected storage services in the final stage of recovery, which caused a brief second outage
    Action items
    • Audit the management device architecture to segment it better (target Q3 2026)
    • Evaluate and implement ways to prevent unintended VLAN changes, such as improved configuration safeguards or automation scripts (target Q1 2026)
Check your cluster for this

These 2 cases involve Network switch and Transit gateway or network interconnect. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause1