  1. Symptoms

    Event ingestion and the Honeycomb UI in EU1 became unavailable at 22:00:10 UTC on April 9, 2024, and the status page reported that the EU1 instance was down. Both the ingestion service and the service behind the web UI stopped at roughly the same moment.

    Trigger

    A routine system update to the Kubernetes cluster, rolled out earlier on April 9, followed by a regular deployment that replaced pods one at a time.

    Root cause
    Component
    Contributing factor
    Detection

    The first status post, saying the EU1 instance was down, went up at 15:08 PDT (22:08 UTC), about 8 minutes after the outage began. There was no alerting on the AWS Load Balancer Controller.

    Remediation
    • Restarted the AWS Load Balancer Controller
    • Rolled back the Kubernetes cluster system update
    Action items
    • Find the exact cause of the failure so the system update can be deployed safely
    • Add monitoring and alerting on the AWS Load Balancer Controller so on-call engineers learn of a failure quickly and can pause deployments
    Lessons

    A rolling deployment can look healthy while the component that wires new pods into the load balancer is broken; the failure only shows when the last old pod goes away. Honeycomb now treats the AWS Load Balancer Controller as a critical component that needs its own alerting, so deployments can be paused before they remove the last pods that still receive traffic. Extensive testing in development and staging did not reveal the bad interaction.

  2. Symptoms

    LOTTE ON, Lotte E-commerce's online shopping mall of about 40 microservices on Amazon EKS, returned errors for a period of time whenever the Horizontal Pod Autoscaler (HPA) scaled pods in after load dropped. Requests reached containers that had already been deleted and failed with 502 errors.

    Trigger

    HPA scale-in deleting pods, and the deletion of Blue pods after a blue/green switch of the Service label selector.

    Root cause
    Component
    Contributing factor
    Remediation
    • delayed container shutdown on pod deletion (a wait in the SIGTERM handler or a preStop sleep, capped by terminationGracePeriodSeconds) so containers stop only after the pod has left the Service endpoints
    • switched some workloads' Ingress-created ALBs from instance mode to IP mode so traffic goes straight to pod IPs without iptables and conntrack
    Action items
    • Move all workloads to ALB IP mode gradually
    Lessons

    Removing a pod from Service endpoints and stopping its containers happen at the same time in Kubernetes, so a pod can stop while traffic is still routed to it unless shutdown is delayed with a preStop hook or in the application. With an instance-mode ALB, traffic passes through node iptables and conntrack, and established connections can keep going to a pod IP after its iptables rules are gone. IP mode avoids that path, within the limit of 1000 targets per target group.

  3. Symptoms

    The graph of WebSocket connections to messaging-hub, the messaging platform used by the Japanese food delivery service Demaecan, showed sudden deep drops even outside peak traffic. The drops kept coming back at irregular intervals. Messages still reached clients, because messaging-hub switches to Firebase Cloud Messaging when a WebSocket is gone.

    Trigger

    Another service that shared the same L7 load balancer deployed its own load balancer configuration in the Verda dashboard, which reloaded HAProxy; 30 minutes later, at the hard-stop-after limit, the old HAProxy process exited and closed every WebSocket connection it still held.

    Root cause
    Component
    Contributing factor
    Detection

    The developer noticed deep, sudden drops in the WebSocket connection graph that were not tied to peak traffic and kept recurring irregularly. The Nginx packet drops were found through network monitoring.

    Remediation
    • separated the Merchant system's token issuance API into its own deployment so reconnect traffic did not delay other Merchant APIs
    • scaled out Nginx with pod anti-affinity and a label selector so each pod ran on a different node, which stopped the nf_conntrack packet drops
    • raised Ingress Nginx proxy-read-timeout and proxy-send-timeout and the load balancer timeout to 3600s, which did not stop the drops
    • moved messaging-hub from the shared L7 load balancer to an L4 load balancer, which ended the WebSocket drops
    Lessons

    A reload of a shared load balancer by a different team can cut long-lived connections, and with hard-stop-after the cut comes 30 minutes later, far from the change that caused it. The author's lesson is not to narrow the scope of the search too early: trusting that the infrastructure was fine kept the investigation inside the team's own systems for days. A reconnect wave from many WebSocket clients can overload the systems that issue connection tokens and fill nf_conntrack on proxy nodes. Scaling Nginx out only helps for conntrack if the pods land on different nodes, and anti-affinity leaves extra replicas Pending once they outnumber the nodes. That messaging-hub problems can still load the connected systems remains an open problem.

  4. Symptoms

    At 07:53 UTC on 2022-03-31 the rate of 50x errors on GitLab.com went up, and at 07:54 PagerDuty paged the engineer on call (EOC) about the rising error rate. Users saw slow pages and intermittent 50x error pages. The incident lists the Web, API, Git and Pages services as affected.

    Trigger

    A k8s-workloads/gitlab-com pipeline deployed merge request !1643, a GitLab chart bump that changed the port names of Kubernetes Services and Deployments (related to the Prometheus service and pod monitors), starting with the canary environment gprd-cny at 07:49 UTC.

    Root cause
    Component
    Contributing factor
    Detection

    A PagerDuty alert on the rising error rate paged the EOC at 07:54 UTC, one minute after the 50x errors went up. The engineer deploying the change noticed the errors and linked them to it.

    Remediation
    • drained the canary environment and re-enabled it after twenty minutes
    • cancelled the deployment jobs for clusters c and d before they started
    • drained gprd-us-east1-d in HAProxy and re-enabled it five minutes later
    • raised the minimum replica count above 100 (merge request !1650)
    • drained gprd-us-east1-c in HAProxy, deployed the change to it, and re-enabled it
    • reverted the minimum replica increase (merge request !1652)
    Action items
    • Implement graceful draining of a whole regional cluster
    • Create a Chatops command that puts PagerDuty into maintenance mode
    Lessons

    Renaming ports on Kubernetes Services and Deployments behind a GCP load balancer made the load balancer reconfigure, and requests were slow or timed out until the new configuration had fully applied, which took minutes. GitLab notes that alerting worked well. The follow-up work is a way to drain a whole regional cluster gracefully and a Chatops command to put PagerDuty into maintenance mode.

  5. Symptoms

    At 08:00 UTC on 2021-09-06 every service in DFDS's Kubernetes cluster answered with 404. Investigation started five minutes later.

    Trigger

    The automated Kubernetes node rollover on 2021-09-06 restarted all the Traefik v2 pods, five days after a malformed IngressRoute manifest had been applied.

    Root cause
    Component
    Contributing factor
    Detection

    All services returned 404 from 08:00 UTC and root cause investigation started at 08:05. Time to detection was 5 minutes.

    Remediation
    • changed the ALB health check path, which made the targets healthy but did not stop the 404s
    • rolled back by hand to Traefik v1 as the main ingress controller
    • deleted the malformed IngressRoute by hand and confirmed the Traefik v2 bug
    • applied the changes upstream
    Action items
    • Upgrade Traefik to v2.5, where the bug is fixed, and verify that it removes the bug
    • Change the Traefik v2 health check path to something more robust
    • Set up an external liveness probe on the ingress controller
    • Consider workload segmentation to limit the blast zone
    • Look into monitoring the Traefik v2 API for rapid changes
    • Look into smoke testing during and after node rollover
    Lessons

    A malformed IngressRoute did nothing visible for five days and then took down all ingress when every Traefik v2 pod had restarted during a node rollover. Because Traefik v2 failed gracefully, the first signals pointed at the ALB health checks instead of at Traefik. On incident handling, the team concluded that appointing an incident manager could have helped, that the war room meeting should be recorded and a log book kept, that people not involved should only make suggestions in writing, and that a short first round of sharing thoughts and gut feelings is useful.

Check your cluster for this

These 15 cases involve Cloud load balancer and Ingress controller. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause6

Faulty deployment1 case

Organisation
  1. IL-0188 Rolling updates on EKS returned 502 errors for about 30 seconds because Kubernetes deleted old pods as soon as new pods passed readiness, before the ALB had marked the new pod targets healthy

Software defect4 cases

  1. IL-0150 A latent race condition in DynamoDB's DNS automation left an empty DNS record for dynamodb.us-east-1.amazonaws.com, and the DynamoDB and EC2 launch failures that followed caused EKS, ECS and Fargate container launch failures and cluster scaling delays in us-east-1
  2. IL-0131 A new kind of GenerateContent request made Vertex AI prediction API servers segfault, and once enough of them restarted at the same time the serving fleet could not carry the load
  3. IL-0106 A malformed Traefik IngressRoute triggered a Traefik v2 bug once a node rollover restarted every Traefik pod, and all Kubernetes services returned 404
    DFDS2021
  4. IL-0030 Most nodes of a cluster went NotReady together for 15 minutes while the API server sat behind an AWS ELB

Breaking change in an upgrade2 cases

  1. IL-0079 A GKE node auto-upgrade to an ubuntu_containerd image with a kernel regression left kube-proxy unable to apply its ip6tables rules, so load balancer health checks failed and several clusters lost all ingress traffic
  2. IL-0203 A routine Kubernetes cluster system update made the AWS Load Balancer Controller fail, so new pods were never registered with the ALB and Honeycomb's EU1 ingest and UI went down once the last old pods were replaced

Configuration change6 cases

  1. IL-0192 A Crossplane composition merge-policy change for a TLS policy update switched Kubernetes Services from LoadBalancer to ClusterIP and deleted the load balancers behind about 25% of Grafana Cloud services
  2. IL-0177 WebSocket connections to LINE's messaging-hub on Kubernetes dropped all at once whenever another service's change reloaded a shared HAProxy L7 load balancer, and the reconnect wave overloaded a token API and filled nf_conntrack on Nginx
    LINE+2022
  3. IL-0208 A GitLab chart bump that renamed Kubernetes Service and Deployment ports made the GCP load balancer reconfigure, and GitLab.com slowed down and returned intermittent 50x errors
    GitLab2022
  4. IL-0111 Switching the main Kubernetes ingress controller from Traefik v1 to v2 stopped X-Forwarded headers being passed, which broke the Okta login flow for every service using Okta and stopped DFDS online bookings for over an hour
    DFDS2021
  5. IL-0105 Replacing the AWS VPC CNI during a Terraform refactoring detached the ALB target groups, and every service in the Kubernetes cluster returned 503
    DFDS2021
  6. IL-0052 A cryptocurrency miner ran on every node of the development and staging clusters through a public, unauthenticated Weave Scope dashboard

DNS or network fault1 case

Contributing factor
Organisation
  1. IL-0178 On EKS, HPA scale-in returned 502 errors because containers stopped before their pod IPs left the Service endpoints, and after blue/green switches conntrack kept sending established connections to deleted pods behind an instance-mode ALB

Operator error1 case

  1. IL-0089 A test cluster deletion script run with the kube context pointing at the live-1 production cluster deleted its ingress controller, monitoring, logging, cert-manager, kiam and external-dns