Incident Library
Applied filters Root causeDependency failureSymptomNetwork unreachableClear allEvery case under the filters, with no sentence; newest first.
Suggested filters Search, and the values found in your words appear here.

Graph

  • Root cause
  • Component
  • Symptom
  • Contributing factor
  • Case

Cases6 cases

3 to 6 of 6

  1. Symptoms

    From about 03:00 UTC on 30 June 2023, Fastmail and a fraction of the internet could not communicate with each other, and Fastmail first heard of it from customers through support tickets and social media. The problem lasted about 19 hours and affected an estimated 3-5% of customers as well as some email servers.

    Root cause
    Component
    Contributing factor
    Detection

    Customers told Fastmail through support tickets and social media. Fastmail's own monitors in multiple locations and its staff were not on affected networks and saw nothing.

    Action items
    • Select a provider for a second transit connection directly into Fastmail's servers, via Megaport or a provider present in 365's New Jersey datacenter, so that Fastmail controls the outbound path and can route around a network with problems
    Lessons

    With a single path for outbound traffic, Fastmail could not route around a provider's network problem and could not fix it itself. Being able to choose between several outbound paths would let Fastmail get everyone back online faster.

  2. Symptoms

    On 10 January 2023 at 16:37 UTC Icinga reported "BGP status on cr3-eqsin is CRITICAL: BGP CRITICAL - AS1299/IPv6: Active - Telia, AS1299/IPv4: Active - Telia", and from 16:45 the hosts in Wikimedia's eqsin site went DOWN with "PING CRITICAL - Packet loss = 100%". Users normally directed to eqsin, mostly in the APAC region, could only read Wikipedia pages already cached in eqsin.

    Trigger

    Planned maintenance by the transport provider took down eqsin's second transport link while the first was still down from a long fiber cut.

    Root cause
    Component
    Contributing factor
    Detection

    Automated monitoring: Icinga BGP status alerts for cr3-eqsin at 16:37 and cr2-eqsin at 16:44, followed by a flood of host-down alerts and three pages at the same time.

    Remediation
    • Depooled eqsin from DNS
    • Repooled eqsin
    Action items
    • Create a backup GRE tunnel for eqsin (T327265)
    • Ensure the long-down transport link comes back up properly once it is fixed (T322529)
    • Automatically parse maintenance notifications and alert on conflicting maintenance (T230835)
    Lessons

    The site was depooled quickly, and "depool first, investigate later" was the right attitude. A flood of host-down alerts usually means a network problem. eqsin stayed too long on a single working transport link, SREs did not catch that the downtime of the two transport links overlapped, and the provider's planned maintenance was not recorded in a task or reminder.

  3. Symptoms

    At about 08:49 UTC on 2 June 2019, Packet's internal network monitoring alerted on serious reachability and performance problems in several of Packet's global datacenter locations. The first investigation found routing loops and traffic being blackholed to specific internal and Internet destinations.

    Trigger

    A trans-continental US backbone link in the network of Packet's upstream provider Zayo had a hardware failure and blackholed IP traffic routed over it.

    Root cause
    Component
    Contributing factor
    –
    Detection

    Packet's internal network monitoring alerted at 08:49 UTC on reachability issues in several global datacenter locations, and engineers confirmed them at 08:52.

    Remediation
    • Migrated traffic to an alternative network and removed Zayo from the provider mix
    • Applied route filters to return service to normal
    • Optimised specific routing policies to improve latency across the backbone with the new traffic mix
    Action items
    • Expand internal connectivity monitoring and alerting of on-call operations teams
    • Expand network automation and routing so traffic can be balanced across all available backbone paths and an operator can trigger automated re-routes across all Packet datacenters in a major provider incident
    • Make Packet's provisioning systems less dependent on third party network providers and inter-datacenter connectivity
  4. Symptoms

    At 4.50am Melbourne time on Sunday 7 February (evening of 6 February UTC), FastMail became unavailable and stayed unreachable for almost two hours. Traffic to FastMail's public IP range never made it into FastMail's own network.

    Trigger

    The GRE tunnels between Level 3 and NYI, which carried FastMail's filtered traffic into its network, went down.

    Root cause
    Component
    Contributing factor
    Detection

    NYI, the datacentre provider, noticed the failure quickly.

    Remediation
    • NYI escalated with Level 3's support until FastMail's public IP ranges were pointed back to NYI
    Action items
    • Go back to DDoS protection from Black Lotus under NYI's explicit control
    • Build nginx frontends in the Los Angeles datacentre that reach NYI over the secondary network, and point DNS to them if NYI's primary network fails
    • Add hardware in Amsterdam and change the delivery system so it depends less on NYI
    • Work with NYI to understand its processes for detecting and responding to network faults
    Lessons

    Much of FastMail's and NYI's reliability had come from NYI controlling its own infrastructure. With protection always on at Level 3, NYI could not restore the routes itself, and FastMail calls the resulting delay in restoring service unacceptable.

Check your cluster for this

These 6 cases involve BGP routing and ISP and transit networks. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause1