  1. Symptoms

    On 5 October 2023 in us-central1, newly created VMs waited a long time before their networking worked, and VMs that had been live migrated lost connectivity for a long time after the migration. Networking telemetry showed cross-region packet loss to and from us-central1 from 03:08 US/Pacific. Health check state of VMs reached load balancers late.

    Trigger

    A management plane behaviour change, meant to decouple the processing of API updates to Instance Groups and Network Endpoint Groups used as load balancer backends, was deployed in us-central1 after rolling out to several other regions without incident.

    Root cause
    Component
    Contributing factor
    Detection

    Engineers were alerted to slowness in the virtual network control plane in us-central1 at 21:45 US/Pacific on 4 October, before the packet loss started, and to controller failures from memory exhaustion at 02:11 on 5 October. Networking telemetry showed cross-region packet loss from 03:08.

    Remediation
    • Increased the memory allocated to the virtual network router controllers
    • Rolled back the management plane change in us-central1
    • Restarted by hand the routers that were still not accepting updates
    Action items
    • Alert proactively on memory risks and unexpected memory increases
    • Refactor the deployment configuration so engineers can reallocate memory much faster
    • Re-evaluate existing practices and add safety mechanisms for API reconciliation
    • Make management plane changes more visible across teams so the changes can be correlated faster
    • Adjust the deployment footprint so a regional API change is less likely to exhaust memory across the region at once
    • Optimise memory use in the traffic routers and their controllers
  2. Symptoms

    From 09:55 UTC on 9 August 2023, DigitalOcean's AMS3, LON1 and SFO2 datacenters lost Internet access in waves of 10 to 15 minutes, about an hour apart. Users saw connectivity issues, latency and timeout errors on Droplets and on Droplet-based services such as Load Balancers, Kubernetes and Database clusters.

    Trigger

    The edge routers received an RPKI-related routing update, and the operating system software on them crashed its routing process on that update.

    Root cause
    Component
    Contributing factor
    Remediation
    • Rolled out a software update to the edge routers running the affected version, site by site
    • Rebalanced traffic on the congested routes between AMS3 and FRA1
    • Rolled out the fix to the redundant networking equipment so a failover would not hit the bug
    Action items
    • Upgrade all global edge routers to remove the bug
    • Bring the network upgrades already done in Asia to Europe and North America
  3. Symptoms

    From 07:08 UTC on 25 January 2023, customers saw long network latency and timeouts when connecting to resources in Azure regions and to other Microsoft services such as Microsoft 365 and Power Platform. Microsoft's monitoring detected DNS and WAN issues from 07:11 UTC.

    Trigger

    A network engineer adding capacity to the global WAN in Madrid ran a step of a recently changed standard operating procedure that purged the IGP database; on the router manufacturer involved, that command runs on all IGP-joined routers instead of only the local one.

    Root cause
    Component
    Contributing factor
    Detection

    Monitoring detected DNS and WAN issues from 07:11 UTC and alerted the on-call engineers within 5 minutes of the command being run. The team reviewed all recent changes and identified the command by 08:20 UTC. The engineer making the change was not informed of the alerts because of the unqualified changes to the SOP.

    Remediation
    • Restarted by hand the paused WAN health and traffic engineering systems, which ended the remaining packet loss
    Action items
    • Audit and block similar widespread-impact commands across all three vendors for all WAN router roles
    • Give on-call engineers real-time visibility of approved and unqualified activity on network devices
    • Run regular mandatory operational training and attestation of following all SOPs
    • Have the Change Advisory Board review all SOPs still pending qualification within 30 days
  4. Symptoms

    On 25 October 2021 from about 11:16, traffic to the DNS servers in KT's network rose sharply, and then KT's internet service failed across the whole country. KT recognised the internet outage at 11:20, and the outage lasted about 89 minutes until KT finished recovery at about 12:45.

    Trigger

    During the replacement of an enterprise network router at KT's Busan office, worked on remotely from the Busan communication center, a worker entered a routing configuration script that lacked the 'exit' command that should have ended the IS-IS part of the configuration.

    Root cause
    Component
    Contributing factor
    Detection

    KT recognised the internet outage at 11:20, four minutes after DNS traffic began to surge at 11:16. The Ministry of Science and ICT saw the traffic increase in its own monitoring, and KT reported the outage to the ministry at 11:40.

    Remediation
    • Isolated the router where the faulty routing configuration was entered
    • Logged in to each regional router, deleted the faulty processes and restarted them
    Action items
    • Check the network management of major carriers, including their work procedures and the systems that stop technical errors from spreading
    • Consider having major carriers introduce simulation systems that diagnose errors from network work in advance
    • Have the NMS center and network operations center of each major carrier check technically that approved work plans are followed
    • Strengthen safeguards in routing work, such as limiting the number of route entries updated at once below a set level
    • Strengthen the monitoring of carriers' outages and develop technology, including AI-based preventive diagnosis, for network stability and resilience
    • Prepare structural measures for a stable network architecture and network survivability
    • Let carriers notify users of outages through SNS, text messages and other means, not only the website
    Lessons

    The investigation named management problems and technical problems. On the management side, work approved for the night was done during the day, partner company workers did the routing work without a work manager, and the work was done with the network still connected. On the technical side, the two pre-verification steps were people reading the script and missed the missing 'exit', there was no virtual testbed for trying the work on a disconnected network, and nothing stopped an error in one region from spreading to the whole country.

  5. Symptoms

    At 09:20 CET on 13 October 2021, during a planned change on a router, IPv4 traffic across OVHcloud's whole network stopped being routed, while all IPv6 traffic stayed reachable. The team detected a problem with the router's performance at 09:21 CET and escalated at once.

    Trigger

    A planned change to a router in the Vint Hill datacentre in the United States, meant to strengthen anti-DDoS protection, included a command to regulate the redistribution of BGP into OSPF, and the router did not interpret that command correctly.

    Root cause
    Component
    Contributing factor
    Detection

    At 09:21 CET the team detected a problem with the router's performance and started the escalation process.

    Remediation
    • Disconnected the optical equipment to isolate the router's connectivity
    • Powered off the faulty router
    • Stabilised connectivity to restore the remaining services
    Action items
    • Re-evaluate the change procedure for this type of equipment, which applies the command line natively
    • Strengthen the related change process
Check your cluster for this

These 12 cases involve BGP routing and Network control plane (SDN). kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause5

Capacity exhaustion1 case

Organisation
  1. IL-0350 Hosts in an IONOS TXL cluster lost connectivity when an InfiniBand fabric resweep failed on a full multicast table

Operator error2 cases

  1. IL-0349 IONOS Private Cloud in Berlin lost management access, storage and VM internet routing after a VLAN change
  2. IL-0337 EBS volumes in one US East Availability Zone got stuck after a network change cut EBS nodes off from their replicas

Software defect5 cases

  1. IL-0347 About 25% of Scaleway FR-PAR-1 hypervisors lost VPC connectivity when both VPC BGP route reflectors got stuck
  2. IL-0529 New Google Cloud VMs and other instances came up without network connectivity in all zones after VPC controllers stopped
  3. IL-0342 DigitalOcean's AMS3, LON1 and SFO2 data centers lost Internet connectivity in repeated waves as edge routers failed
  4. IL-0222 Google Cloud US regions had heavy packet loss and some went unreachable after the network control plane was descheduled
  5. IL-0396 New or live-migrated GCE instances, VPN tunnels and network load balancers were unreachable on public IPs for over 2h

Faulty deployment1 case

Organisation
  1. IL-0530 Virtual router controllers in us-central1 ran out of memory in a loop, cutting networking for new and migrated VMs

Configuration change3 cases

  1. IL-0225 An IGP purge command made every Microsoft WAN router recompute routes, causing global latency, timeouts and packet loss
  2. IL-0539 KT's internet service failed nationwide for about 89 minutes as wrong routes spread from one router in Busan
    KT2021