  1. Symptoms

    When traffic changed sharply, CoreDNS came under heavy load, and the cluster saw network problems and a sudden rise in latency. The horizontal pod autoscaler then added pods, database connections surged, and the impact spread to the whole service.

    Trigger

    Sharp changes in traffic loaded the small number of CoreDNS pods beyond what they could handle.

    Root cause
    Component
    Contributing factor
    Remediation
    • Set up the Cluster Proportional Autoscaler for CoreDNS with nodesPerReplica and coresPerReplica chosen for the instance types in use
    • Spread CoreDNS with soft topologySpreadConstraints (ScheduleAnyway) instead of anti-affinity so Karpenter could consolidate nodes
    • Added alert thresholds on CoreDNS error rate, panics, request duration and request rate
    • Deployed NodeLocal DNSCache so each node answers DNS from a local cache and forwards misses to the main CoreDNS
    Lessons

    A fixed, small number of CoreDNS pods cannot follow a cluster whose nodes and pods change quickly with traffic, and the damage spreads: DNS latency triggers autoscaling, which in turn floods the database with connections. Simply adding many CoreDNS replicas created a different problem, because with tainted nodes and a maxSkew: 1 spread constraint the pods piled onto a few nodes and blocked Karpenter consolidation. Scaling CoreDNS in proportion to the cluster and putting a DNS cache on every node handled both.

  2. Symptoms

    From 08:00 US/Pacific on 12 March 2024, GKE GPU nodes running Container-Optimized OS (COS) that were newly created or recreated came up with GPU drivers that did not work, so workloads that used the GPUs could not run. GKE showed elevated errors.

    Root cause
    Component
    Contributing factor
    Detection

    The report does not say how Google detected the issue. Affected users saw "Failed to download GPU driver installer, status: 403 Forbidden" on the GPU node when installing the driver.

    Remediation
    • Halted automatic node recreations, which attempt GPU driver downloads, until the issue was mitigated
    • Worked with the driver partner to resolve access to the driver download bucket
    Lessons

    The status page report states no lessons or follow-up actions.

  3. Symptoms

    At 01:04 CET on 13 February 2024, the Kubernetes API behind Scaleway's managed Kubernetes services Kapsule and Kosmos in the Paris region (FR-PAR) spiked in RAM and CPU use and ran out of memory. Nodes in FR-PAR could no longer authenticate to their control plane, and some of them went "Not Ready". Customers on both shared (mutualized) and dedicated environments were affected.

    Trigger

    A new Kubernetes release was made available to all users on 12 February 2024, and during the night of 12 to 13 February many clusters triggered their auto-upgrade at the same time.

    Root cause
    Component
    Contributing factor
    Detection

    The timeline's first entry, at 01:04 CET, records the Kubernetes API's RAM and CPU spikes and out-of-memory state, with nodes unable to authenticate to their control plane and some becoming "Not Ready". The first recorded action, 42 minutes later at 01:46, was to increase the resources allocated to the API.

    Remediation
    • increased the resources allocated to the Kubernetes API at 01:46 and again at 02:20
    • applied API traffic restrictions at 02:30 to smooth the incoming traffic
    • removed the traffic restrictions progressively in 50-100 batches from 03:20
    • ran a script at 03:40 to replace the failing nodes created during the congestion
    • rolled back to the former node authentication mechanism, first on a subset of clusters from 15:45 and on all clusters by 19:41 on 19 February
    • disabled cluster upgrade and configuration update features until 10:30 on 20 February
    Action items
    • Increase the resources allocated to the Kubernetes API
    • Roll back to the former node authentication mechanism
    • Implement a local authentication cache on nodes
    • Rework the resource allocation strategy to behave better under load spikes
    • Add new request queuing mechanisms for Kubernetes
    • Separate the different components to reduce side effects under high load or failure
    • Monitor selected metrics closely to identify anomalous patterns earlier
    • Refund customers who deployed nodes during the incident but could not use them normally
    Lessons

    Letting many clusters auto-upgrade at the same moment after a release turns routine upgrades into one coordinated load spike on the shared Kubernetes API. A node authentication mechanism that retries without letting up turns a slow API into an unavailable one, and auto-healing that replaces NotReady nodes amplifies the problem. The congestion pattern had already appeared three weeks earlier, and short-term mitigations did not stop it from recurring, so Scaleway rolled back the new authentication mechanism. Scaleway notes that as the number of customer clusters and nodes grows sharply, traffic control mechanisms have to improve to prevent congestion.

  4. Symptoms

    At 13:02 UTC on 2024-01-23 DigitalOcean posted that, as of 12:18 UTC, its engineers were investigating an issue with Kubernetes clusters in the FRA1 region and that users might see errors when communicating with their clusters. The control planes of the affected DOKS (DigitalOcean Kubernetes) clusters had become inaccessible.

    Trigger

    An incorrect configuration was applied to an internal infrastructure cluster in FRA1 at 12:21 UTC during a maintenance operation.

    Root cause
    Component
    Contributing factor
    Detection

    Engineers were investigating errors with Kubernetes clusters in FRA1 as of 12:18 UTC and identified the incorrect configuration as the cause at 12:36.

    Remediation
    • restored each affected cluster's etcd from its latest twice-daily backup
    • restored the stateless control plane components after etcd
    • patched the recovery mechanism after unexpected problems during recovery
    • found and fixed an additional small bug during recovery
    • contacted affected customers directly with further instructions, since some might need to reconfigure Kubernetes resources
    Action items
    • Prevent automatic deletion of infrastructure cluster resources under any circumstances in the production environment
    Lessons

    When managed control planes run as resources in another cluster, one configuration mistake in that cluster can delete hundreds of control planes at once through ordinary automation. The etcd backups limited the damage, but their twice-daily schedule set the worst case at 12 hours of lost control plane state, and the recovery tooling itself needed patching during the incident.

  5. Symptoms

    Standard alerting paged Honeycomb's on-call engineers about the performance and stability of event ingestion, and the automated load-shedding mechanisms tripped and sent further notifications. The status page described a higher than normal error rate and response time on the ingestion service.

    Trigger

    An abnormally large number of queries arrived from many separate connections within a few minutes.

    Root cause
    Component
    Contributing factor
    Detection

    Standard alerting notified the on-call engineers about ingestion performance and stability, and the automated load-shedding mechanisms added notifications when they tripped. The first status post, about alerts on a higher than normal error rate and response time, went up at 18:28 PST (02:28 UTC), 13 minutes after the 02:15 UTC start.

    Remediation
    • Scaled the ingest fleet up manually and aggressively
    • Cut off most ingest for a few minutes so the ingest hosts could come back with enough capacity
    • Temporarily lowered the rate limits for the most aggressive traffic sources until their traffic subsided
    Action items
    • Keep the ingest fleet scaled up to prevent a repeat while longer-term fixes are worked on
    • Decide on the projects that will address these failure paths
    Lessons

    Load shedding and auto-scaling were in place, yet a burst that arrived faster than the cache could spread its writes still took the ingest hosts down. During recovery, Kubernetes' crash loop back-off worked against the operators: the hosts that had failed stayed offline while the fleet needed every host. Clients that retry whole OTel batches after a partial drop can multiply traffic many times over, so per-source rate limits were what finally stabilised ingest.

Check your cluster for this

These 29 cases involve Application database and Node operating system image. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause7

Faulty deployment1 case

Organisation
  1. IL-0136 A deployment that cleared an internal service's caches at peak traffic sent 20 times the normal load to the Azure OpenAI metadata backend in Sweden Central, and health checks that depended on its database restarted instances in a loop for almost six hours

Capacity exhaustion7 cases

  1. IL-0102 CoreDNS pods on a production EKS cluster ran out of memory under a burst of new pods, endpoints and nodes, taking down the Buildkite web UI, APIs and job dispatch
  2. IL-0182 Too few CoreDNS replicas on EKS were overloaded during traffic spikes, raising latency and cutting the network for task pods, and the over-provisioned, tightly spread CoreDNS pods added later blocked Karpenter consolidation
  3. IL-0168 Simultaneous cluster auto-upgrades overloaded Scaleway's Kubernetes API, and a node authentication retry loop kept Kapsule and Kosmos nodes NotReady in FR-PAR
  4. IL-0202 A burst of queries and database writes exhausted connection pools and memory on Honeycomb's ingest hosts, and Kubernetes crash-loop back-off kept failed hosts offline so ingest capacity stayed too low to recover
  5. IL-0037 Image registry rate-limited a whole region after a crash-looping DaemonSet with imagePullPolicy Always pulled through three NAT instances
  6. IL-0064 CPU-heavy pods packed onto one Google Cloud node drove it to kernel panics, and the crash moved from node to node until the site was down
  7. IL-0036 A reindex Job that kept failing exhausted one node after another until the whole cluster was down

Software defect6 cases

  1. IL-0124 Capacity changes queued while a circuit breaker was engaged ran all at once when it was released, taking multiple OpenAI inference engines out of service and raising API error rates
    OpenAI2026
  2. IL-0150 A latent race condition in DynamoDB's DNS automation left an empty DNS record for dynamodb.us-east-1.amazonaws.com, and the DynamoDB and EC2 launch failures that followed caused EKS, ECS and Fargate container launch failures and cluster scaling delays in us-east-1
  3. IL-0171 Karpenter node auto-repair replaced EKS GPU nodes about 10 minutes after they became Ready, in a loop, because the Bottlerocket NVIDIA AMI lacked libdcgm.so and set AcceleratedHardwareReady to False
    Inflab2025
  4. IL-0147 AKS nodes behind an HTTP proxy failed to provision with CSE exit code 31 on 202508 node images, because a refactoring stopped the proxy from being used when downloading uncached Kubernetes binaries
  5. IL-0112 The daily node rollover put DFDS's EKS nodes on an AMI later recalled for a kernel issue, causing "PLEG is not healthy" NodeNotReady flaps and pod network timeouts
    DFDS2022
  6. IL-0132 A faulty resource cleanup process marked Vertex AI prediction endpoints as deleted worldwide, undeploying customers' models and failing predictions for 4 hours 20 minutes

Dependency failure3 cases

  1. IL-0187 A brief Spring Cloud Config Server downtime failed every client application's liveness probe, because the actuator health check included the config server, and Kubernetes restarted the pods in a kill loop
  2. IL-0021 GKE GPU nodes on Container-Optimized OS could not download NVIDIA drivers (403 Forbidden) and came up without working GPUs
  3. IL-0073 Intermittent Kafka connectivity overloaded Docker daemons, set off a node rescheduling cascade and poisoned the Consul gossip mesh
    Target2019

Breaking change in an upgrade3 cases

  1. IL-0117 A scheduled maintenance and an ingress upgrade on OpenAI's user-facing clusters caused a networking control plane regression that briefly broke the data plane, and the services that restarted then overwhelmed a backend persistence store with a heavy first-start query
    OpenAI2024
  2. IL-0198 An automatic Ubuntu security update restarted systemd-networkd, which flushed the IP rules Cilium relied on and cut more than 60 percent of Datadog's Kubernetes nodes off the network across regions and cloud providers
  3. IL-0144 A systemd security update installed by unattended-upgrades lost the DNS configuration of Ubuntu 18.04 VMs, so AKS kubelets could not resolve registry names and pods failed with ImagePullBackOff

Configuration change8 cases

  1. IL-0152 An incorrect configuration applied during maintenance made an internal infrastructure cluster automatically delete the control planes of 200 DOKS clusters in FRA1
  2. IL-0109 A retried node rollover on a DFDS EKS cluster set the Auto Scaling group back to 15 instances, and the default termination policy removed every healthy worker node, leaving the cluster with no nodes
    DFDS2023
  3. IL-0009 A duplicated generated name made Argo CD replace the InfluxDB Cloud production Application and delete the whole production environment
  4. IL-0208 A GitLab chart bump that renamed Kubernetes Service and Deployment ports made the GCP load balancer reconfigure, and GitLab.com slowed down and returned intermittent 50x errors
    GitLab2022
  5. IL-0010 A templating change that dropped its {{ }} delimiters made Argo CD delete all 478 Skyscanner services in every region
  6. IL-0008 An unresponsive OPA validating webhook crash-looped the API server during a GKE master upgrade, and node auto-repair then recreated every node
  7. IL-0004 A new default pod priority let a new Cortex cluster preempt every production ingester in a cascade, taking Grafana Cloud Hosted Prometheus down
  8. IL-0055 A failing CronJob with the default concurrency policy piled up thousands of restarting pods and took down a cluster
    Target2018

DNS or network fault1 case

Organisation
  1. IL-0049 Partial DNS outage after CoreDNS scaled down and kube-proxy failed to delete stale conntrack entries
    Preply2020