  1. Symptoms

    Within hours of launching the full SmolLM3 pretraining run (3B parameters, 11T tokens, 384 H100 GPUs on 48 nodes), training throughput fell steeply, with repeated sharp drops. The team expected a steady 13,500 to 14,000 tokens per second, and none of the throughput ablations run beforehand on the same 48 nodes had shown drops.

    Trigger

    Launching the full run with the whole ~24 TB dataset on shared WekaFS storage and the real step count for 11T tokens, both far larger than in the ablation runs.

    Root cause
    Component
    Contributing factor
    Detection

    The team watched training throughput in tokens per second and saw it fall within hours of launch; node-monitoring metrics then tied the large fall to spikes in disk read latency.

    Remediation
    • moved the training data from WekaFS to the local NVMe RAID scratch storage on each node
    • copied the dataset to replacement nodes from a healthy node with fpsync, cutting the copy from 3 hours to 1.5 hours
    • kept a spare node with the dataset preloaded in the Slurm reservation to swap in when a node failed
    • reproduced the drops on a single node and with step counts of about 3M and 32k to rule out hardware and isolate the step count
    • replaced nanotron's nanosets dataloader with the TokenizedBytes dataloader copied from the SmolLM2 setup, which removed the drops
    • pre-shuffled the tokenized sequences offline for each epoch with different seeds (about 1 hour) to fix the noisier loss from TokenizedBytes
    Lessons

    Ablations on data subsets and a short step horizon did not exercise either cause: a shared cache-and-evict filesystem near its capacity, and a dataloader index that grows with the step count. Reproducing the drops on one node separated hardware from software, and varying only the step count pointed at the dataloader. The team chose proven replacements over repairs under deadline pressure, taking an existing dataloader instead of fixing nanosets and offline shuffling instead of changing the dataloader, and warns that too many such shortcuts leave a patchwork system that is hard to maintain.

  2. Symptoms

    From early August 2025 a number of users reported that Claude's responses had become worse. At first the reports were hard to tell apart from the normal variation in user feedback. By late August they had become frequent and persistent enough for Anthropic to open an investigation.

    Trigger

    A bug from 5 August that sent some Sonnet 4 requests to servers configured for the upcoming 1M-token context window; a misconfiguration deployed to the Claude API TPU servers on 25 August; token-selection and sampling-code changes deployed on 25 and 26 August that removed a December 2024 workaround and exposed a latent XLA:TPU compiler bug; and a routine load-balancing change on 29 August that increased the misrouted traffic.

    Root cause
    Component
    Contributing factor
    Detection

    User reports of degraded responses from early August, including reports online. They were hard to tell apart from normal feedback variation, and their rising frequency and persistence by late August led Anthropic to open an investigation; internal evaluations did not detect the degradation.

    Remediation
    • Fixed the routing logic so short- and long-context requests go to the correct server pools (deployed 4 September, rolled out to all platforms by 18 September)
    • Rolled back the TPU server change that corrupted token generation (2 September)
    • Rolled back the top-k sampling change for Haiku 3.5 (4 September), Opus 3 (12 September) and Sonnet 4
    • Switched from approximate to exact top-k and standardized some additional operations on fp32 precision
    Action items
    • Add detection tests for unexpected character outputs to the deployment process
    • Develop more sensitive evaluations that reliably tell working and broken implementations apart
    • Run quality evaluations continuously on true production systems
    • Build infrastructure and tooling to debug community-sourced feedback faster without sacrificing user privacy
    • Fix the approximate top-k compiler bug together with the XLA:TPU team
    Lessons

    Benchmarks, safety evaluations and canary deployments missed degradation that users noticed, partly because the model often recovers from isolated mistakes, and Anthropic relied too heavily on noisy evaluations, with no clear way to connect rising reports to each of its recent changes. Overlapping bugs with different symptoms on different platforms looked like random degradation, and privacy controls on user interactions kept engineers from examining the interactions needed to identify or reproduce the bugs. Anthropic concluded that it needs evaluations running continuously on production and a continuous signal from users, such as the /bug command in Claude Code and the thumbs-down button in the Claude apps.

  3. Symptoms

    From 17 October 2024, packets through the vSwitch that joined Namespace's bare metal machines at one provider in the fra3 region were dropped at random. Retries in TCP, QUIC and the Namespace control plane hid most of it, but the SLO error budget for latency targets on key interactions began to burn.

    Trigger

    Random packet drops on the bare metal provider's vSwitch from 17 October 2024; for the second outage, a rate of Kubernetes changes that the slow NVMe on one control plane node could no longer keep up with.

    Root cause
    Component
    Contributing factor
    Detection

    SLO-based monitoring of latency targets showed the error budget burning while retries hid the individual packet drops.

    Remediation
    • diverted all customer traffic from fra3 to other regions
    • connected each provider machine to the zrh1 cluster over Wireguard instead of the vSwitch
    • repaved every fra3 machine with a new identity, certificates and encryption-at-rest keys, dropping regional caches to recover faster
    • cloned existing datasets in a more distributed way to speed up repaving the machines
    • added machines back to the new region in batches and returned the region to the compute pool
    • redirected workloads away from zrh1 during the second outage
    • cloned the failing control plane node's key state to a higher-capacity node that took over its role and IP address
    Action items
    • Credit all instances that ran during the outages back to customers
    • Build up backup regions and solutions so a similar event has options that do not affect customers
    Lessons

    Running hot with a delayed hardware delivery left no room to take a region out, so fixing a provider network fault turned into a global capacity shortage. After one outage the team was anchored on its cause and first looked for network problems in the second outage, which had a different cause: a control plane node whose disk could not keep up with the Kubernetes change rate.

  4. Symptoms

    At 08:45 CET on 22 April 2024 the Hugging Face Hub became unstable, and by 09:30 it was unresponsive. For most users the website was slow or could not be reached at all.

    Trigger

    Bursts of requests to revision endpoints that read heavily from the *_info_cache collections: a call to https://huggingface.co/api/datasets/lighteval/mmlu/revision/main rose sharply right before the first crash, and a call to https://huggingface.co/api/models/sentence-transformers/all-mpnet-base-v2/revision/main, a model with 300+ associated spaces, lined up with the crash at 21:30 on 23 April.

    Root cause
    Component
    Contributing factor
    Detection

    Instability started at 08:45 on 22 April and the Hub was unresponsive by 09:30; the team followed MongoDB Atlas metrics and a MongoDB support case. The root cause was found days later from a new graph of requests per URL.

    Remediation
    • Added a firewall rule blocking all requests with a Java/* user agent
    • Disabled the quicksearch feature on the Hub
    • Scaled the MongoDB Atlas cluster by hand from tier 2 to tier 3
    • Switched the Hub to maintenance mode with a 503 page through AWS WAF and blocked incoming traffic
    • Scaled all Hub pods down to 0 and brought them back
    • Set an aggressive rate limit
    • Added timeouts to requests and reworked database queries that were slow or returned large bodies
    Action items
    • Add timeouts to requests based on their usual completion time
    • Optimise requests that took too long or returned a large body, and rework poorly designed database queries
    • Remove old unused indexes from the database
    • Build new dashboards and monitoring metrics
    • Move the *_info_cache collections to Redis
    • Make it possible to abort any database request when the client aborts theirs
    Lessons

    Finding the root cause took two to three days: the existing charts did not show it, and a per-URL request breakdown did. Not cancelling database work when a client goes away turns a strained database into a thundering herd. A close inspection of the database exposed architectural flaws and bottlenecks, such as a collection with large unused indexes, and taught the team which metrics need closer watching to anticipate crashes. Unrelated failures happening at the same time added to the stress and made restoring service harder.

  5. Symptoms

    At 16:40 UTC on 19 April 2024 CoW Protocol's mainnet production environment stopped producing settlements; the outage officially began then.

    Trigger

    During a cluster capacity expansion, the Infrastructure as Code automation updated the AWS VPC CNI plugin, because the CNI version was not hardcoded in the IaC and the IaC library version had recently changed.

    Root cause
    Component
    Contributing factor
    Detection

    The CNI version mismatch was identified as the cause at 17:03 UTC, 23 minutes after settlements stopped.

    Remediation
    • upgraded the Kubernetes cluster
    • set up new node groups with a new version of the networking plugin
    Lessons

    Versions in IaC scripts should be specified explicitly so an automation run cannot update a component such as the CNI plugin unintentionally. Changes in production need change management that is easy to revert.

Check your cluster for this

These 14 cases involve Cluster autoscaler and Node pool. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause7

Dependency failure2 cases

  1. IL-0133 A storm shut down cooling at Nebius's us-central1 data center, and a disk hot-plug bug kept Managed Kubernetes control planes down for hours after power returned
    Nebius2026
  2. IL-0135 A power source switch during UPS maintenance cut power to a row of GPU servers and shut down Crusoe Cloud VMs in us-northcentral1

Capacity exhaustion1 case

Organisation
  1. IL-0129 Throughput of the 384-GPU SmolLM3 pretraining run collapsed because shared WekaFS storage evicted dataset shards to S3, then kept dropping on local NVMe because the nanotron dataloader built an index that grew with the step count

Software defect4 cases

  1. IL-0022 Three overlapping infrastructure bugs (context-window misrouting, TPU output corruption and an XLA top-k miscompilation) degraded Claude's responses
  2. IL-0024 Expensive cache-backed API calls and uncancelled database requests overloaded MongoDB and took the Hugging Face Hub down three times
  3. IL-0112 The daily node rollover put DFDS's EKS nodes on an AMI later recalled for a kernel issue, causing "PLEG is not healthy" NodeNotReady flaps and pod network timeouts
    DFDS2022
  4. IL-0003 linkerd lost Kubernetes service discovery after an etcd reconfiguration, and restarting every linkerd instance turned failed payments into a full platform outage
    Monzo2017

Cloud provider outage4 cases

  1. IL-0084 Packet drops on a bare metal provider's vSwitch forced Namespace to rebuild its fra3 region and left global capacity short, and the next day slow NVMe writes on a control plane node drove the Kubernetes API server to very high CPU
  2. IL-0205 The GKE cluster autoscaler could not add nodes to GitLab.com's production cluster because Google Cloud ran out of SSD persistent disks in us-east1
    GitLab2021
  3. IL-0193 A GCP persistent disk degradation took down a Cassandra StatefulSet whose OrderedReady policy blocked recovery, and Metrictank could not reconnect to the recreated pods, causing a 23-hour Graphite query outage
  4. IL-0014 A GKE upgrade to a withdrawn version stalled on slow drains and a stuck node pool, then broke an ingress and confused the HPA

Configuration change1 case

Organisation
  1. IL-0114 An unpinned AWS VPC CNI plugin was updated automatically during a capacity expansion, leaving new pods Pending without IP addresses and stopping CoW Protocol settlements for about 3.5 hours

Operator error1 case

Organisation
  1. IL-0115 One of OpenAI's three production AKS clusters went offline through a human error, and rebuilding it took 10½ hours because an AKS Kubernetes upgrade broke the ingress and AKS cannot be downgraded
    OpenAI2022

DNS or network fault1 case

Organisation
  1. IL-0199 A non-essential container exceeding its memory limit made GitHub's production pods unavailable, and their restarts failed because a DNS maintenance change had left the clusters unable to reach the image registry
    GitHub2020