Incident Library
  • Root cause
  • Component
  • Symptom
  • Contributing factor
  • Case

Cases29 cases

12 to 16 of 29

  1. Symptoms

    At 13:02 UTC on 2024-01-23 DigitalOcean posted that, as of 12:18 UTC, its engineers were investigating an issue with Kubernetes clusters in the FRA1 region and that users might see errors when communicating with their clusters. The control planes of the affected DOKS (DigitalOcean Kubernetes) clusters had become inaccessible.

    Trigger

    An incorrect configuration was applied to an internal infrastructure cluster in FRA1 at 12:21 UTC during a maintenance operation.

    Root cause
    Component
    Contributing factor
    Detection

    Engineers were investigating errors with Kubernetes clusters in FRA1 as of 12:18 UTC and identified the incorrect configuration as the cause at 12:36.

    Remediation
    • restored each affected cluster's etcd from its latest twice-daily backup
    • restored the stateless control plane components after etcd
    • patched the recovery mechanism after unexpected problems during recovery
    • found and fixed an additional small bug during recovery
    • contacted affected customers directly with further instructions, since some might need to reconfigure Kubernetes resources
    Action items
    • Prevent automatic deletion of infrastructure cluster resources under any circumstances in the production environment
    Lessons

    When managed control planes run as resources in another cluster, one configuration mistake in that cluster can delete hundreds of control planes at once through ordinary automation. The etcd backups limited the damage, but their twice-daily schedule set the worst case at 12 hours of lost control plane state, and the recovery tooling itself needed patching during the incident.

  2. Symptoms

    Standard alerting paged Honeycomb's on-call engineers about the performance and stability of event ingestion, and the automated load-shedding mechanisms tripped and sent further notifications. The status page described a higher than normal error rate and response time on the ingestion service.

    Trigger

    An abnormally large number of queries arrived from many separate connections within a few minutes.

    Root cause
    Component
    Contributing factor
    Detection

    Standard alerting notified the on-call engineers about ingestion performance and stability, and the automated load-shedding mechanisms added notifications when they tripped. The first status post, about alerts on a higher than normal error rate and response time, went up at 18:28 PST (02:28 UTC), 13 minutes after the 02:15 UTC start.

    Remediation
    • Scaled the ingest fleet up manually and aggressively
    • Cut off most ingest for a few minutes so the ingest hosts could come back with enough capacity
    • Temporarily lowered the rate limits for the most aggressive traffic sources until their traffic subsided
    Action items
    • Keep the ingest fleet scaled up to prevent a repeat while longer-term fixes are worked on
    • Decide on the projects that will address these failure paths
    Lessons

    Load shedding and auto-scaling were in place, yet a burst that arrived faster than the cache could spread its writes still took the ingest hosts down. During recovery, Kubernetes' crash loop back-off worked against the operators: the hosts that had failed stayed offline while the fleet needed every host. Clients that retry whole OTel batches after a partial drop can multiply traffic many times over, so per-source rate limits were what finally stabilised ingest.

  3. Symptoms

    Between 06:00 and 07:00 UTC on 8 March 2023, Kubernetes nodes in several Datadog regions lost network connectivity at the same time, on AWS, Google Cloud and Azure. All services across multiple regions were affected, including the regions that host Datadog's CI/CD and automation tools. Datadog's regions are not connected to each other and changes are rolled out one region at a time, so a simultaneous failure on several cloud providers looked implausible at first.

    Trigger

    On 7 March 2023 Ubuntu published a systemd patch for a CVE (249.11-0ubuntu3.7). Ubuntu's default unattended upgrades installed it on the nodes between 06:00 and 07:00 UTC on 8 March, and installing it restarted systemd-networkd.

    Root cause
    Component
    Contributing factor
    Remediation
    • restarted thousands of disconnected instances on Google Cloud and Azure through the cloud APIs, keeping their local disks
    • rebuilt the data lost with terminated AWS instances' local disks through replication, reprocessing and restores from backup
    Lessons

    A change in a base operating system component can stay dormant for months until something restarts that component. Here the trigger was a security patch, and the change reached every region at once because automatic OS updates ran outside the progressive, region-by-region process used for every other change. Cloud providers react differently to an instance that loses its network. Google Cloud and Azure left the instances running, so a restart recovered them with their disks; AWS replaced them quickly, which brought stateless services back fast but destroyed the local-disk data the stateful services needed.

  4. Symptoms

    At 09:33 UTC on 14 February 2023 end users told the platform team that Kubernetes logs were not arriving in CloudWatch as expected. The investigation went through fluentd and found that the nodes were running containerd as their container runtime instead of docker-shim. A scheduled node rollover the day before, at 07:30 UTC on 13 February, had set containerd as the default runtime by accident.

    Trigger

    A scheduled node rollover had accidentally made containerd the default container runtime, which stopped log shipping to CloudWatch; the unscheduled rollover to revert it timed out, and the pipeline run that followed reduced the Auto Scaling group from 30 to 15 instances.

    Root cause
    Component
    Contributing factor
    Detection

    End users reported the missing CloudWatch logs that started the work. The postmortem lists 2 minutes as the time to detection of the node failure.

    Remediation
    • ran the node rollover script to add new nodes, which failed on a timeout from Docker Hub
    • ran the node rollover script a second time, which added new nodes that the load balancer marked healthy at 11:01 UTC
    Action items
    • Document the rollover process, especially what can be done when it goes wrong
    • Investigate options for improving the rollover process
    • Add fluentd log collection to the QA test suite so logs are covered end to end
    • Add alarms for fluentd when too little or no log data is sent
    • Implement a staging environment
    • Implement guards against selecting an invalid container runtime
    Lessons

    When a change goes wrong, rolling back to a known working configuration is safer than rushing a fix, which can make the damage worse. Launching new worker nodes depends on the cloud-init script not failing in any way. The QA configuration differed from production, there was no staging environment, the QA tests did not cover fluentd log collection, and the rollover process had no documentation for when it fails.

  5. Symptoms

    On 2022-10-31 a planned upgrade of the vpc-cni EKS add-on, started from the deployment pipeline at 13:45 UTC, timed out at 14:10. Only about 10 of the 45 aws-node pods had upgraded, 5 were stuck in Terminating and the other 30 had not been attempted.

    Trigger

    At 07:30 UTC on 2022-10-31 the daily node rollover replaced the existing nodes with nodes built from AMI v20221027, the latest AWS EKS node AMI, released on 2022-10-29 and later recalled because of a kernel issue.

    Root cause
    Component
    Contributing factor
    Detection

    The team noticed nodes flapping between NodeNotReady and NodeReady ("KubeletNotReady PLEG is not healthy") at 14:30 UTC while watching the stalled vpc-cni upgrade, about seven hours after the rollover. Time to detection was 7 hours. Alerting did not catch the NodeNotReady events or the socket growth.

    Remediation
    • cordoned, drained and deleted 15 stuck nodes one at a time to complete the vpc-cni upgrade
    • changed the Terraform infrastructure-modules so a specific AMI could be set
    • rolled the EC2 Auto Scaling group launch configuration back to the previous known good AMI through the pipeline
    Action items
    • Reach out to teams with suggestions about readiness and liveness probes
    • Create a dashboard for readiness and liveness probe coverage
    • Write a wiki article on readiness and liveness probes and their usefulness
    • Modify infrastructure-modules to allow specifying a particular AMI
    • Schedule a discussion on whether to take the latest AMI immediately and how to test new AMIs before they are deployed
    • Implement alerting on abnormal NodeNotReady events and on increased socket use
    • Create a learning path for Kubernetes within the team
    • Collect logs from nodes centrally
    • Create a Prometheus exporter that retrieves the latest available AMI, with a dashboard and alerts
    Lessons

    When a new node AMI has just been rolled out, upgrading other cluster components on the same day makes it hard to tell which change is causing trouble; here the vpc-cni upgrade on the same day confused matters. Taking the latest AMI automatically with no way to pin one meant a rollback first needed a Terraform change. The team also concluded that it needs better communication paths with application teams during incidents.

Check your cluster for this

These 29 cases involve Application database and Node operating system image. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause7

Faulty deployment1 case

Organisation
  1. IL-0136 A deployment that cleared an internal service's caches at peak traffic sent 20 times the normal load to the Azure OpenAI metadata backend in Sweden Central, and health checks that depended on its database restarted instances in a loop for almost six hours

Capacity exhaustion7 cases

  1. IL-0102 CoreDNS pods on a production EKS cluster ran out of memory under a burst of new pods, endpoints and nodes, taking down the Buildkite web UI, APIs and job dispatch
  2. IL-0182 Too few CoreDNS replicas on EKS were overloaded during traffic spikes, raising latency and cutting the network for task pods, and the over-provisioned, tightly spread CoreDNS pods added later blocked Karpenter consolidation
  3. IL-0168 Simultaneous cluster auto-upgrades overloaded Scaleway's Kubernetes API, and a node authentication retry loop kept Kapsule and Kosmos nodes NotReady in FR-PAR
  4. IL-0202 A burst of queries and database writes exhausted connection pools and memory on Honeycomb's ingest hosts, and Kubernetes crash-loop back-off kept failed hosts offline so ingest capacity stayed too low to recover
  5. IL-0037 Image registry rate-limited a whole region after a crash-looping DaemonSet with imagePullPolicy Always pulled through three NAT instances
  6. IL-0064 CPU-heavy pods packed onto one Google Cloud node drove it to kernel panics, and the crash moved from node to node until the site was down
  7. IL-0036 A reindex Job that kept failing exhausted one node after another until the whole cluster was down

Software defect6 cases

  1. IL-0124 Capacity changes queued while a circuit breaker was engaged ran all at once when it was released, taking multiple OpenAI inference engines out of service and raising API error rates
    OpenAI2026
  2. IL-0150 A latent race condition in DynamoDB's DNS automation left an empty DNS record for dynamodb.us-east-1.amazonaws.com, and the DynamoDB and EC2 launch failures that followed caused EKS, ECS and Fargate container launch failures and cluster scaling delays in us-east-1
  3. IL-0171 Karpenter node auto-repair replaced EKS GPU nodes about 10 minutes after they became Ready, in a loop, because the Bottlerocket NVIDIA AMI lacked libdcgm.so and set AcceleratedHardwareReady to False
    Inflab2025
  4. IL-0147 AKS nodes behind an HTTP proxy failed to provision with CSE exit code 31 on 202508 node images, because a refactoring stopped the proxy from being used when downloading uncached Kubernetes binaries
  5. IL-0112 The daily node rollover put DFDS's EKS nodes on an AMI later recalled for a kernel issue, causing "PLEG is not healthy" NodeNotReady flaps and pod network timeouts
    DFDS2022
  6. IL-0132 A faulty resource cleanup process marked Vertex AI prediction endpoints as deleted worldwide, undeploying customers' models and failing predictions for 4 hours 20 minutes

Dependency failure3 cases

  1. IL-0187 A brief Spring Cloud Config Server downtime failed every client application's liveness probe, because the actuator health check included the config server, and Kubernetes restarted the pods in a kill loop
  2. IL-0021 GKE GPU nodes on Container-Optimized OS could not download NVIDIA drivers (403 Forbidden) and came up without working GPUs
  3. IL-0073 Intermittent Kafka connectivity overloaded Docker daemons, set off a node rescheduling cascade and poisoned the Consul gossip mesh
    Target2019

Breaking change in an upgrade3 cases

  1. IL-0117 A scheduled maintenance and an ingress upgrade on OpenAI's user-facing clusters caused a networking control plane regression that briefly broke the data plane, and the services that restarted then overwhelmed a backend persistence store with a heavy first-start query
    OpenAI2024
  2. IL-0198 An automatic Ubuntu security update restarted systemd-networkd, which flushed the IP rules Cilium relied on and cut more than 60 percent of Datadog's Kubernetes nodes off the network across regions and cloud providers
  3. IL-0144 A systemd security update installed by unattended-upgrades lost the DNS configuration of Ubuntu 18.04 VMs, so AKS kubelets could not resolve registry names and pods failed with ImagePullBackOff

Configuration change8 cases

  1. IL-0152 An incorrect configuration applied during maintenance made an internal infrastructure cluster automatically delete the control planes of 200 DOKS clusters in FRA1
  2. IL-0109 A retried node rollover on a DFDS EKS cluster set the Auto Scaling group back to 15 instances, and the default termination policy removed every healthy worker node, leaving the cluster with no nodes
    DFDS2023
  3. IL-0009 A duplicated generated name made Argo CD replace the InfluxDB Cloud production Application and delete the whole production environment
  4. IL-0208 A GitLab chart bump that renamed Kubernetes Service and Deployment ports made the GCP load balancer reconfigure, and GitLab.com slowed down and returned intermittent 50x errors
    GitLab2022
  5. IL-0010 A templating change that dropped its {{ }} delimiters made Argo CD delete all 478 Skyscanner services in every region
  6. IL-0008 An unresponsive OPA validating webhook crash-looped the API server during a GKE master upgrade, and node auto-repair then recreated every node
  7. IL-0004 A new default pod priority let a new Cortex cluster preempt every production ingester in a cascade, taking Grafana Cloud Hosted Prometheus down
  8. IL-0055 A failing CronJob with the default concurrency policy piled up thousands of restarting pods and took down a cluster
    Target2018

DNS or network fault1 case

Organisation
  1. IL-0049 Partial DNS outage after CoreDNS scaled down and kube-proxy failed to delete stale conntrack entries
    Preply2020