  1. Symptoms

    At 14:10 an engineer deployed a change to a service that Monzo's current account needs to process payments, and every request to that service started to fail. Current account customers saw payment failures; the prepaid card was not affected at first because it does not use that service. The change was rolled back at 14:12, but the errors continued.

    Trigger

    At 14:10 an engineer deployed a change to a service needed to process current account payments. Two weeks earlier the etcd cluster had been upgraded and grown from three to nine nodes, and one day earlier another team had scaled a new service down to zero replicas while leaving its Kubernetes service in place.

    Root cause
    Component
    Contributing factor
    Detection

    Payment failures began right after the 14:10 deploy. The team rolled back at 14:12 and declared an outage internally at 14:16. At 15:13, when no service could serve requests, practically all automated alerts fired.

    Remediation
    • Rolled back the payments service change (the errors continued)
    • Activated internal backup processes so most customers could still use their card
    • Restarted all linkerd instances (this made the outage worse)
    • Restarted the three Kubernetes API server processes so replacement linkerd instances could start
    • Began deploying a newer linkerd version with the fix for empty services
    • Deleted the Kubernetes service that had no endpoints, which let linkerd load service discovery again
    Action items
    • Fix the bug in Kubernetes that can trigger timeouts after a cluster reconfiguration
    • Roll out a new version of linkerd that fixes the parsing error
    • Create better health checks, dashboards and alerts for the affected components so they give clearer signals about what is wrong and prevent human error
    • Improve procedures to communicate outages internally and externally as clearly and quickly as possible
    Lessons

    A large failure in a distributed system can be very hard to understand, and well-meant human action can compound it, as restarting every linkerd instance did here by exposing a second incompatibility. Because Monzo deploys often and its network changes constantly, the deployment and request-routing systems have to be trustworthy. Monzo committed to publishing a similar post-mortem for any incident of this severity.

Check your cluster for this

These 14 cases involve Cluster autoscaler and Node pool. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause7

Dependency failure2 cases

  1. IL-0133 A storm shut down cooling at Nebius's us-central1 data center, and a disk hot-plug bug kept Managed Kubernetes control planes down for hours after power returned
    Nebius2026
  2. IL-0135 A power source switch during UPS maintenance cut power to a row of GPU servers and shut down Crusoe Cloud VMs in us-northcentral1

Capacity exhaustion1 case

Organisation
  1. IL-0129 Throughput of the 384-GPU SmolLM3 pretraining run collapsed because shared WekaFS storage evicted dataset shards to S3, then kept dropping on local NVMe because the nanotron dataloader built an index that grew with the step count

Software defect4 cases

  1. IL-0022 Three overlapping infrastructure bugs (context-window misrouting, TPU output corruption and an XLA top-k miscompilation) degraded Claude's responses
  2. IL-0024 Expensive cache-backed API calls and uncancelled database requests overloaded MongoDB and took the Hugging Face Hub down three times
  3. IL-0112 The daily node rollover put DFDS's EKS nodes on an AMI later recalled for a kernel issue, causing "PLEG is not healthy" NodeNotReady flaps and pod network timeouts
    DFDS2022
  4. IL-0003 linkerd lost Kubernetes service discovery after an etcd reconfiguration, and restarting every linkerd instance turned failed payments into a full platform outage
    Monzo2017

Cloud provider outage4 cases

  1. IL-0084 Packet drops on a bare metal provider's vSwitch forced Namespace to rebuild its fra3 region and left global capacity short, and the next day slow NVMe writes on a control plane node drove the Kubernetes API server to very high CPU
  2. IL-0205 The GKE cluster autoscaler could not add nodes to GitLab.com's production cluster because Google Cloud ran out of SSD persistent disks in us-east1
    GitLab2021
  3. IL-0193 A GCP persistent disk degradation took down a Cassandra StatefulSet whose OrderedReady policy blocked recovery, and Metrictank could not reconnect to the recreated pods, causing a 23-hour Graphite query outage
  4. IL-0014 A GKE upgrade to a withdrawn version stalled on slow drains and a stuck node pool, then broke an ingress and confused the HPA

Configuration change1 case

Organisation
  1. IL-0114 An unpinned AWS VPC CNI plugin was updated automatically during a capacity expansion, leaving new pods Pending without IP addresses and stopping CoW Protocol settlements for about 3.5 hours

Operator error1 case

Organisation
  1. IL-0115 One of OpenAI's three production AKS clusters went offline through a human error, and rebuilding it took 10½ hours because an AKS Kubernetes upgrade broke the ingress and AKS cannot be downgraded
    OpenAI2022

DNS or network fault1 case

Organisation
  1. IL-0199 A non-essential container exceeding its memory limit made GitHub's production pods unavailable, and their restarts failed because a DNS maintenance change had left the clusters unable to reach the image registry
    GitHub2020