  1. Symptoms

    At 11:48 PM PDT on 19 October 2025, every system that reached DynamoDB in us-east-1 through the public regional endpoint started getting DNS failures and could not connect. This included customer traffic and internal AWS services that depend on DynamoDB. DynamoDB global table replicas in other regions still answered but fell behind in replication to and from us-east-1.

    Trigger

    One DNS Enactor, slowed by unusually high retry delays, applied a much older DNS plan to the regional DynamoDB endpoint just as another Enactor that had applied the newest plan ran its clean-up, which deleted that older plan and with it every IP address of the endpoint.

    Root cause
    Component
    Contributing factor
    Detection

    DNS failures to DynamoDB began immediately at 11:48 PM PDT and the engineering teams of affected AWS services were engaged at once; by 12:38 AM they had identified DynamoDB's DNS state as the source. The later NLB health check problem was detected by monitoring at 6:52 AM.

    Remediation
    • applied temporary mitigations by 1:15 AM that let some internal services reach DynamoDB and repaired key internal tooling
    • restored all DynamoDB DNS information by 2:25 AM through manual operator intervention
    • throttled incoming work and selectively restarted DWFM hosts from 4:14 AM so droplet leases could be re-established
    • reduced the load on Network Manager to bring network configuration propagation times back to normal by 10:36 AM
    • disabled automatic health check failover for NLB at 9:36 AM, and re-enabled it at 2:09 PM after EC2 recovered
    • relaxed the EC2 request throttles from 11:23 AM until all EC2 APIs and launches were normal at 1:50 PM
    Action items
    • Disable the DynamoDB DNS Planner and DNS Enactor automation worldwide
    • Fix the race condition and add protections against applying incorrect DNS plans before re-enabling the DNS automation
    • Add a velocity control to NLB that limits how much capacity a single load balancer can remove when health check failures cause availability zone failover
    • Build an additional EC2 test suite that exercises the DWFM recovery workflow at scale
    • Improve throttling in EC2 data propagation systems so incoming work is rate limited by the size of the waiting queue
    Lessons

    A single DNS record that automation can empty is enough to take a widely used regional endpoint off the network, and every service built on it fails in turn. A check made once at the start of a long operation can be stale by the time the operation writes its result. Recovery of the dependency is not recovery of the dependents: systems that lost state during the outage, such as EC2's droplet leases and network propagation backlog, can collapse under their own catch-up work, and container services that rely on new instance launches keep failing to launch and scale until that work is done.

  2. Symptoms

    While the Spring Cloud Config Server was briefly down for an upgrade, every client application began to answer its liveness probe with a failure saying it could not reach the config server.

    Trigger

    A downtime upgrade of the Spring Cloud Config Server made it stop responding for a short time.

    Root cause
    Component
    Contributing factor
    Lessons

    A liveness probe that includes an external dependency turns a short outage of that dependency into a restart loop of every client. Keep external dependencies out of liveness checks and handle temporary problems with readiness probes. Libraries can add health indicators to Spring Boot's actuator health endpoint automatically, so check what the probe path actually reports. The author ran another Kubernetes environment for two years without liveness probes, relying on strict readiness probes and on the application terminating itself on unrecoverable faults.

  3. Symptoms

    GPU nodes for an AI video upscaling job were created normally and reached Ready, and then about 10 to 11 minutes later Karpenter treated each one as unhealthy and replaced it. Every new node went the same way, so the GPU pods kept restarting and the upscaling work could not make progress.

    Trigger

    Enabling Karpenter's node auto-repair feature gate (nodeRepair: true) and then running GPU pods on nodes from the Bottlerocket NVIDIA AMI.

    Root cause
    Component
    Contributing factor
    Detection

    The team noticed GPU nodes being replaced repeatedly after running GPU pods, then found the DCGMError message in the node events.

    Remediation
    • Disabled Karpenter node auto-repair by setting the nodeRepair feature gate to false
    Lessons

    Automatic node repair acts on every unhealthy node condition, including AcceleratedHardwareReady, so an image defect that only breaks GPU health monitoring is enough to have every GPU node terminated and recreated in a loop. Before turning on auto-repair, check which conditions it watches and whether the node image reports them correctly. Disabling auto-repair stops the loop at once but is only a temporary measure; installing the missing library or changing the AMI address the cause but cost more on an immutable OS such as Bottlerocket.

  4. Symptoms

    Creating or scaling a node pool on AKS 1.31.8 failed: the VMSS instances never finished provisioning. This started after planned maintenance moved the node image from 202507.* to 202508.*, in a cluster where nodes must send all outbound traffic through an internal HTTP/HTTPS proxy and direct egress is blocked. It happened with both Ubuntu and AzureLinux images.

    Trigger

    A node image auto-upgrade from 202507.* to 202508.* during planned maintenance, on clusters whose Kubernetes patch version was not pre-cached in the new image.

    Root cause
    Component
    Contributing factor
    Detection

    The customer saw VMSS instance provisioning fail with a vmssCSE error in the VMSS activity logs and reported it as a GitHub issue.

    Remediation
    • The customer pinned the node image to a 202507.* snapshot on clusters running 1.31.8
    • The customer upgraded clusters to AKS 1.31.9 or 1.31.10, whose binaries are cached in the 202508.* images
    • The AKS team hot-patched VHD 20250811 so the proxy configuration is used for uncached binary downloads and made it globally available in public regions on 2025-09-04; it also announced the hotfix for VHD 20250820
    • The AKS team told users to reimage their nodes with az aks nodepool upgrade --node-image-only to pick up the hotfixed image
    Action items
    • Apply the proxy fix in all future VHDs
    Lessons

    A bootstrap path that runs only when an artefact is missing from a cache is easy to break without noticing: here only clusters on Kubernetes versions not pre-cached in the node image ever downloaded binaries, so only they met the proxy regression. Testing node provisioning behind a mandatory egress proxy, on older patch versions as well as the newest, would exercise that path. For clusters with restricted egress, pinning the node image or moving to a Kubernetes version cached in the image were both quick workarounds while the fix was shipped.

  5. Symptoms

    On August 16, 2024 from 11:38 AM to 1:16 PM PT, the OpenAI primary API was unreliable: ChatGPT conversations succeeded less often, and logging in and creating accounts were affected. The status page called it elevated error rates for ChatGPT and the Platform API. The incident came in two waves, of 44 and 15 minutes.

    Trigger

    A scheduled maintenance combined with an upgrade to the ingress of OpenAI's user-facing clusters.

    Root cause
    Component
    Contributing factor
    Action items
    • Mitigate the networking control plane regression and validate that control plane restarts do not interfere with the clusters' data plane
    • Change service software to start faster and remove the first-start query, relieving the persistence layer
    • Deploy configuration changes that optimise the networking control plane's effect on the clusters' ability to handle traffic
    • Remove the expensive database query from critical startup paths
    • Add monitoring and alerting for networking control plane issues
    • Introduce staged rollouts with longer soak time for infrastructure changes
    • Audit systems for other slow queries that may affect service start time
    Lessons

    A brief connectivity loss turned into a long outage because recovery itself was expensive: the services that restarted overwhelmed one backend persistence store with a heavy first-start query. Keeping costly queries off startup paths shortens recovery, and staged rollouts with longer soak time limit how many systems an infrastructure regression reaches before it is caught.

Check your cluster for this

These 29 cases involve Application database and Node operating system image. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause7

Faulty deployment1 case

Organisation
  1. IL-0136 A deployment that cleared an internal service's caches at peak traffic sent 20 times the normal load to the Azure OpenAI metadata backend in Sweden Central, and health checks that depended on its database restarted instances in a loop for almost six hours

Capacity exhaustion7 cases

  1. IL-0102 CoreDNS pods on a production EKS cluster ran out of memory under a burst of new pods, endpoints and nodes, taking down the Buildkite web UI, APIs and job dispatch
  2. IL-0182 Too few CoreDNS replicas on EKS were overloaded during traffic spikes, raising latency and cutting the network for task pods, and the over-provisioned, tightly spread CoreDNS pods added later blocked Karpenter consolidation
  3. IL-0168 Simultaneous cluster auto-upgrades overloaded Scaleway's Kubernetes API, and a node authentication retry loop kept Kapsule and Kosmos nodes NotReady in FR-PAR
  4. IL-0202 A burst of queries and database writes exhausted connection pools and memory on Honeycomb's ingest hosts, and Kubernetes crash-loop back-off kept failed hosts offline so ingest capacity stayed too low to recover
  5. IL-0037 Image registry rate-limited a whole region after a crash-looping DaemonSet with imagePullPolicy Always pulled through three NAT instances
  6. IL-0064 CPU-heavy pods packed onto one Google Cloud node drove it to kernel panics, and the crash moved from node to node until the site was down
  7. IL-0036 A reindex Job that kept failing exhausted one node after another until the whole cluster was down

Software defect6 cases

  1. IL-0124 Capacity changes queued while a circuit breaker was engaged ran all at once when it was released, taking multiple OpenAI inference engines out of service and raising API error rates
    OpenAI2026
  2. IL-0150 A latent race condition in DynamoDB's DNS automation left an empty DNS record for dynamodb.us-east-1.amazonaws.com, and the DynamoDB and EC2 launch failures that followed caused EKS, ECS and Fargate container launch failures and cluster scaling delays in us-east-1
  3. IL-0171 Karpenter node auto-repair replaced EKS GPU nodes about 10 minutes after they became Ready, in a loop, because the Bottlerocket NVIDIA AMI lacked libdcgm.so and set AcceleratedHardwareReady to False
    Inflab2025
  4. IL-0147 AKS nodes behind an HTTP proxy failed to provision with CSE exit code 31 on 202508 node images, because a refactoring stopped the proxy from being used when downloading uncached Kubernetes binaries
  5. IL-0112 The daily node rollover put DFDS's EKS nodes on an AMI later recalled for a kernel issue, causing "PLEG is not healthy" NodeNotReady flaps and pod network timeouts
    DFDS2022
  6. IL-0132 A faulty resource cleanup process marked Vertex AI prediction endpoints as deleted worldwide, undeploying customers' models and failing predictions for 4 hours 20 minutes

Dependency failure3 cases

  1. IL-0187 A brief Spring Cloud Config Server downtime failed every client application's liveness probe, because the actuator health check included the config server, and Kubernetes restarted the pods in a kill loop
  2. IL-0021 GKE GPU nodes on Container-Optimized OS could not download NVIDIA drivers (403 Forbidden) and came up without working GPUs
  3. IL-0073 Intermittent Kafka connectivity overloaded Docker daemons, set off a node rescheduling cascade and poisoned the Consul gossip mesh
    Target2019

Breaking change in an upgrade3 cases

  1. IL-0117 A scheduled maintenance and an ingress upgrade on OpenAI's user-facing clusters caused a networking control plane regression that briefly broke the data plane, and the services that restarted then overwhelmed a backend persistence store with a heavy first-start query
    OpenAI2024
  2. IL-0198 An automatic Ubuntu security update restarted systemd-networkd, which flushed the IP rules Cilium relied on and cut more than 60 percent of Datadog's Kubernetes nodes off the network across regions and cloud providers
  3. IL-0144 A systemd security update installed by unattended-upgrades lost the DNS configuration of Ubuntu 18.04 VMs, so AKS kubelets could not resolve registry names and pods failed with ImagePullBackOff

Configuration change8 cases

  1. IL-0152 An incorrect configuration applied during maintenance made an internal infrastructure cluster automatically delete the control planes of 200 DOKS clusters in FRA1
  2. IL-0109 A retried node rollover on a DFDS EKS cluster set the Auto Scaling group back to 15 instances, and the default termination policy removed every healthy worker node, leaving the cluster with no nodes
    DFDS2023
  3. IL-0009 A duplicated generated name made Argo CD replace the InfluxDB Cloud production Application and delete the whole production environment
  4. IL-0208 A GitLab chart bump that renamed Kubernetes Service and Deployment ports made the GCP load balancer reconfigure, and GitLab.com slowed down and returned intermittent 50x errors
    GitLab2022
  5. IL-0010 A templating change that dropped its {{ }} delimiters made Argo CD delete all 478 Skyscanner services in every region
  6. IL-0008 An unresponsive OPA validating webhook crash-looped the API server during a GKE master upgrade, and node auto-repair then recreated every node
  7. IL-0004 A new default pod priority let a new Cortex cluster preempt every production ingester in a cascade, taking Grafana Cloud Hosted Prometheus down
  8. IL-0055 A failing CronJob with the default concurrency policy piled up thousands of restarting pods and took down a cluster
    Target2018

DNS or network fault1 case

Organisation
  1. IL-0049 Partial DNS outage after CoreDNS scaled down and kube-proxy failed to delete stale conntrack entries
    Preply2020