Incident Library
Applied filters FactorNo staged rolloutClear allEvery case under the filters, with no sentence; newest first.
Suggested filters Search, and the values found in your words appear here.

Graph

  • Root cause
  • Component
  • Symptom
  • Contributing factor
  • Case

Cases13 cases

8 to 12 of 13

  1. Symptoms

    At 01:04 CET on 13 February 2024, the Kubernetes API behind Scaleway's managed Kubernetes services Kapsule and Kosmos in the Paris region (FR-PAR) spiked in RAM and CPU use and ran out of memory. Nodes in FR-PAR could no longer authenticate to their control plane, and some of them went "Not Ready". Customers on both shared (mutualized) and dedicated environments were affected.

    Trigger

    A new Kubernetes release was made available to all users on 12 February 2024, and during the night of 12 to 13 February many clusters triggered their auto-upgrade at the same time.

    Root cause
    Component
    Contributing factor
    Detection

    The timeline's first entry, at 01:04 CET, records the Kubernetes API's RAM and CPU spikes and out-of-memory state, with nodes unable to authenticate to their control plane and some becoming "Not Ready". The first recorded action, 42 minutes later at 01:46, was to increase the resources allocated to the API.

    Remediation
    • increased the resources allocated to the Kubernetes API at 01:46 and again at 02:20
    • applied API traffic restrictions at 02:30 to smooth the incoming traffic
    • removed the traffic restrictions progressively in 50-100 batches from 03:20
    • ran a script at 03:40 to replace the failing nodes created during the congestion
    • rolled back to the former node authentication mechanism, first on a subset of clusters from 15:45 and on all clusters by 19:41 on 19 February
    • disabled cluster upgrade and configuration update features until 10:30 on 20 February
    Action items
    • Increase the resources allocated to the Kubernetes API
    • Roll back to the former node authentication mechanism
    • Implement a local authentication cache on nodes
    • Rework the resource allocation strategy to behave better under load spikes
    • Add new request queuing mechanisms for Kubernetes
    • Separate the different components to reduce side effects under high load or failure
    • Monitor selected metrics closely to identify anomalous patterns earlier
    • Refund customers who deployed nodes during the incident but could not use them normally
    Lessons

    Letting many clusters auto-upgrade at the same moment after a release turns routine upgrades into one coordinated load spike on the shared Kubernetes API. A node authentication mechanism that retries without letting up turns a slow API into an unavailable one, and auto-healing that replaces NotReady nodes amplifies the problem. The congestion pattern had already appeared three weeks earlier, and short-term mitigations did not stop it from recurring, so Scaleway rolled back the new authentication mechanism. Scaleway notes that as the number of customer clusters and nodes grows sharply, traffic control mechanisms have to improve to prevent congestion.

  2. Symptoms

    Between 06:00 and 07:00 UTC on 8 March 2023, Kubernetes nodes in several Datadog regions lost network connectivity at the same time, on AWS, Google Cloud and Azure. All services across multiple regions were affected, including the regions that host Datadog's CI/CD and automation tools. Datadog's regions are not connected to each other and changes are rolled out one region at a time, so a simultaneous failure on several cloud providers looked implausible at first.

    Trigger

    On 7 March 2023 Ubuntu published a systemd patch for a CVE (249.11-0ubuntu3.7). Ubuntu's default unattended upgrades installed it on the nodes between 06:00 and 07:00 UTC on 8 March, and installing it restarted systemd-networkd.

    Root cause
    Component
    Contributing factor
    Remediation
    • restarted thousands of disconnected instances on Google Cloud and Azure through the cloud APIs, keeping their local disks
    • rebuilt the data lost with terminated AWS instances' local disks through replication, reprocessing and restores from backup
    Lessons

    A change in a base operating system component can stay dormant for months until something restarts that component. Here the trigger was a security patch, and the change reached every region at once because automatic OS updates ran outside the progressive, region-by-region process used for every other change. Cloud providers react differently to an instance that loses its network. Google Cloud and Azure left the instances running, so a restart recovered them with their disks; AWS replaced them quickly, which brought stateless services back fast but destroyed the local-disk data the stateful services needed.

  3. Symptoms

    On 2022-10-31 a planned upgrade of the vpc-cni EKS add-on, started from the deployment pipeline at 13:45 UTC, timed out at 14:10. Only about 10 of the 45 aws-node pods had upgraded, 5 were stuck in Terminating and the other 30 had not been attempted.

    Trigger

    At 07:30 UTC on 2022-10-31 the daily node rollover replaced the existing nodes with nodes built from AMI v20221027, the latest AWS EKS node AMI, released on 2022-10-29 and later recalled because of a kernel issue.

    Root cause
    Component
    Contributing factor
    Detection

    The team noticed nodes flapping between NodeNotReady and NodeReady ("KubeletNotReady PLEG is not healthy") at 14:30 UTC while watching the stalled vpc-cni upgrade, about seven hours after the rollover. Time to detection was 7 hours. Alerting did not catch the NodeNotReady events or the socket growth.

    Remediation
    • cordoned, drained and deleted 15 stuck nodes one at a time to complete the vpc-cni upgrade
    • changed the Terraform infrastructure-modules so a specific AMI could be set
    • rolled the EC2 Auto Scaling group launch configuration back to the previous known good AMI through the pipeline
    Action items
    • Reach out to teams with suggestions about readiness and liveness probes
    • Create a dashboard for readiness and liveness probe coverage
    • Write a wiki article on readiness and liveness probes and their usefulness
    • Modify infrastructure-modules to allow specifying a particular AMI
    • Schedule a discussion on whether to take the latest AMI immediately and how to test new AMIs before they are deployed
    • Implement alerting on abnormal NodeNotReady events and on increased socket use
    • Create a learning path for Kubernetes within the team
    • Collect logs from nodes centrally
    • Create a Prometheus exporter that retrieves the latest available AMI, with a dashboard and alerts
    Lessons

    When a new node AMI has just been rolled out, upgrading other cluster components on the same day makes it hard to tell which change is causing trouble; here the vpc-cni upgrade on the same day confused matters. Taking the latest AMI automatically with no way to pin one meant a rollback first needed a Terraform change. The team also concluded that it needs better communication paths with application teams during incidents.

  4. Symptoms

    From 06:00 UTC on 30 August 2022, Azure VMs running Ubuntu 18.04 (bionic) with unattended-upgrades enabled began failing DNS resolution and losing network connectivity. Several Azure teams, among them the AKS and Azure Container Apps teams, were alerted by production alerts shortly after the update packages were published.

    Trigger

    Unattended-upgrades on Ubuntu 18.04 VMs installed a Canonical security update published at 06:00 UTC on 30 August 2022, including systemd version 237-3ubuntu10.54.

    Root cause
    Component
    Contributing factor
    Detection

    Several Azure teams, including AKS and Azure Container Apps, were alerted by production alerts shortly after the packages were published; incoming support cases then confirmed which Ubuntu versions were affected.

    Remediation
    • pointed customers to Canonical's description of the systemd bug and its fix
    • recommended rebooting affected VMs or running a template script that repairs DNS resolution
    • built automatic detection and remediation for AKS nodes and rolled it out across all regions
    • mitigated the remaining AKS customers manually through support
    Action items
    • Review the process that lets critical security updates bypass Safe Deployment Practices
    • Improve monitoring of the AKS data plane to alert on an uptick of errors
    • Review AKS monitoring algorithms so that similar VM errors are detected and alerted on
    • Establish an improved escalation path to Canonical during outages and add it to internal Technical Service Guides
    • AKS takes full control of the node security patch mechanism, with additional testing and controlled release of patches (estimated December 2022)
    • Work with Canonical to run dedicated tests on proposed packages before they are published for Azure IaaS VMs
    • Establish a process with Canonical to close the testing gap for the upgrade scenario (estimated March 2023)
    • Give AKS customers maintenance window control and environment staging for these patches (estimated December 2023)
    Lessons

    Security patches applied automatically by unattended-upgrades, once a day by default, and outside Azure's Safe Deployment Practices reached Ubuntu 18.04 VMs in every Azure region, so one systemd regression became a DNS outage across Azure. On AKS, lost node DNS showed up as image pull failures such as ImagePullBackoff, because kubelet could not resolve the registry. Azure plans to put node security patching under AKS's control with testing and controlled release; customers can use automatic node image upgrade for AKS, or automatic VM guest patching for VMs, instead of unattended-upgrades.

  5. Symptoms

    On 25 August 2021, skyscanner.net was unavailable and the Skyscanner mobile apps could not work, for travellers and business partners everywhere at the same time. The full global outage lasted four and a half hours.

    Trigger

    A peer-reviewed change to a rarely changed root-level file of the cells templating configuration, intended as a no-op, that left out the {{ }} delimiters; it was submitted around 15:30 GMT, merged to master and rolled out automatically to every region at once.

    Root cause
    Component
    Contributing factor
    Remediation
    • restored the correct configuration for each cluster and let Argo CD reconcile the cluster back to it
    • restored services through the backup and restoration process
    • brought one region back first with the critical services and served all traffic from it from around 20:30 GMT
    • restored and verified the remaining regions and non-critical services over Thursday and Friday
    Action items
    • Avoid global configuration deploys, including rare change paths like this one
    • Treat templated configuration as code and add testing and linting
    • Plan and wargame more drastic failure scenarios in runbooks
    • Verify backup and restore processes, including access to the backups and the loss of a region
    • Refactor runbooks so they are clear and, where appropriate, idempotent for a stressed engineer in the early morning
    • Reconsider how much configuration is templated across regions, weighing configuration drift against automated global rollout
    Lessons

    Global configuration changes had been prevented in many cases, but not in this rarely used path. Configuration that gains templating and logic has become code and needs tests and at least linting. The failure scenarios and runbooks were not pessimistic enough, a backup only counts once it has been restored, and runbooks need care so they work for a stressed engineer at night. Automation that templates configuration across regions trades drift for the risk of rolling one mistake out everywhere. An experienced incident commander who kept the response calm and blameless made a large difference.

Check your cluster for this

These 13 cases involve Node operating system image and Application database. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause4

Capacity exhaustion2 cases

Organisation
  1. IL-0100 PostHog's feature flags pods were packed onto Kubernetes nodes that were too small for their CPU requests, and CPU saturation above 90% caused three outages in ten days through Redis overload, connection pool exhaustion and slow queries
  2. IL-0168 Simultaneous cluster auto-upgrades overloaded Scaleway's Kubernetes API, and a node authentication retry loop kept Kapsule and Kosmos nodes NotReady in FR-PAR

Configuration change4 cases

  1. IL-0122 An invalid value in a configuration shared by several ChatGPT services put pods into crash loops and raised error rates
    OpenAI2025
  2. IL-0192 A Crossplane composition merge-policy change for a TLS policy update switched Kubernetes Services from LoadBalancer to ClusterIP and deleted the load balancers behind about 25% of Grafana Cloud services
  3. IL-0005 A new telemetry service overloaded the Kubernetes API servers of large clusters and broke DNS-based service discovery for all OpenAI services
    OpenAI2024
  4. IL-0010 A templating change that dropped its {{ }} delimiters made Argo CD delete all 478 Skyscanner services in every region

Breaking change in an upgrade5 cases

  1. IL-0120 A daily scheduled OS update restarted systemd-networkd on cloud-hosted GPU nodes, which conflicted with OpenAI's networking agent and removed all routes, cutting capacity for ChatGPT and the API
    OpenAI2025
  2. IL-0079 A GKE node auto-upgrade to an ubuntu_containerd image with a kernel regression left kube-proxy unable to apply its ip6tables rules, so load balancer health checks failed and several clusters lost all ingress traffic
  3. IL-0117 A scheduled maintenance and an ingress upgrade on OpenAI's user-facing clusters caused a networking control plane regression that briefly broke the data plane, and the services that restarted then overwhelmed a backend persistence store with a heavy first-start query
    OpenAI2024
  4. IL-0198 An automatic Ubuntu security update restarted systemd-networkd, which flushed the IP rules Cilium relied on and cut more than 60 percent of Datadog's Kubernetes nodes off the network across regions and cloud providers
  5. IL-0144 A systemd security update installed by unattended-upgrades lost the DNS configuration of Ubuntu 18.04 VMs, so AKS kubelets could not resolve registry names and pods failed with ImagePullBackOff

Software defect2 cases

Organisation
  1. IL-0112 The daily node rollover put DFDS's EKS nodes on an AMI later recalled for a kernel issue, causing "PLEG is not healthy" NodeNotReady flaps and pod network timeouts
    DFDS2022
  2. IL-0196 Adding a second Redis replica and lowering memory limits in one RedisFailover change restarted the only Redis pod that held data, and Sentinel promoted the empty new replica, erasing the data
    Palark2020