  1. Symptoms

    From September 2021, each rollout of an update to Datadog's metrics query service, which serves real-time and historical metric data to the web frontend and to monitor evaluation, came with a rise in errors. Clients retried failed queries, so few errors reached users, but the retries slowed dashboards and monitors. The service's logs showed DNS errors stopping it from connecting to the data stores it depends on.

    Trigger

    Rollouts of the metrics query service, which delete the old pods. The client behaviour behind the failures came from an August 2021 rollout of the metrics query clients that applied round_robin as the new default gRPC load balancing policy.

    Root cause
    Component
    Contributing factor
    Detection

    Errors rose during rollouts of the metrics query service, and the service's logs showed DNS errors when connecting to its data stores.

    Remediation
    • Raised the memory of the node-local-dns pods from 64 MB to 256 MB, which stopped the OOM kills but not the DNS errors
    • Tested larger instance types and confirmed that scaling up the service's infrastructure resolved the errors
    • Removed the custom gRPC reconnect parameters from the clients to restore the defaults
    Action items
    • Contribute a change to Cilium that adds an unreachable route for a deleted pod's IP so clients get an ICMP error
    Lessons

    The errors looked like DNS but were not. ENA metrics and VPC Flow Logs gave the visibility into VPC connection tracking that host metrics did not, and Cilium, Kubernetes and AWS networking interact in ways that can make reverse path filtering drop packets it should allow. DNS propagation time depends on many settings. The causes were changes Datadog had made itself, to work around a dependency bug, to resolve earlier incidents and to override default reconnect parameters, which looked safe at the time and showed their effects much later, when the link was hard to see.

  2. Symptoms

    In May 2021 some users of seek.com.au got errors when they searched for jobs, for 16 minutes. SEEK was in the middle of moving the traffic between two VPCs, the one that carried searches, from a VPC peering connection to an AWS Transit Gateway, and the team noticed quickly that search was broken.

    Trigger

    In the second step of the migration, SEEK changed the routing table of the first VPC to use the transit gateway while the second VPC still routed over the peering connection, so the two directions of each connection took different paths.

    Root cause
    Component
    Contributing factor
    Detection

    The team noticed soon after the routing change that search on seek.com.au was not working.

    Remediation
    • Rolled back the migration of the search traffic's peering connection to the transit gateway
    Action items
    • Lower the MTU of EC2 instances to 8500, on Amazon Linux 2 with a script at /sbin/ifup-local that runs whenever a network interface comes up
    Lessons

    A transit gateway has a smaller MTU than a same-region peering connection, drops oversized packets silently and clamps the MSS only on packets that cross it. When a migration leaves the two directions of a TCP connection on different paths, the clamp lands on the wrong side of the handshake and large packets are lost; the fix is not to send packets larger than 8500 bytes.

  3. Symptoms

    From 7:30 AM JST on 2 September 2021, AWS Direct Connect customers saw intermittent connectivity problems and elevated packet loss on traffic going to their VPCs in the Tokyo (AP-NORTHEAST-1) Region. Internal AWS alarms on Direct Connect packet loss fired at the same time.

    Trigger

    Customer traffic consistently generated packets with a very specific set of attributes and contents, and these packets set off a latent defect in the network device operating system on one layer of the Direct Connect network in Tokyo.

    Root cause
    Component
    Contributing factor
    Detection

    Internal alarms alerted AWS engineers to elevated packet loss for Direct Connect customers connecting to the Tokyo Region at 7:30 AM JST. The automation that monitors network devices also saw a higher rate of failed devices than normal and alerted engineers.

    Remediation
    • Removed the failing network devices from service so healthy devices carried the traffic, which helped only for a time
    • Reset failed devices and brought them back into service slowly, without stopping the failures
    • Disabled the new protocol in a single Availability Zone, then across the Tokyo Region
    Action items
    • Apply the change carefully to all other AWS Regions, with a new way to detect and remediate the issue before customers are affected
  4. Symptoms

    During the Americas' morning of 4 January 2021, an external monitoring service paged Slack because error rates were creeping up. While the investigation was starting, Slack's own dashboarding and alerting service became unavailable, so responders had to work without their usual dashboards and alerts.

    Trigger

    On the first working day after the holidays, Slack's traffic went from the quietest time of the year to one of its biggest days overnight, with cold client caches pulling more data than usual, and one of Slack's AWS Transit Gateways did not scale fast enough for it.

    Root cause
    Component
    Contributing factor
    Detection

    An external monitoring service paged Slack when error rates started creeping up during the Americas' morning. AWS engineers were separately alerted to the packet drops by AWS's internal monitoring.

    Remediation
    • Disabled automated downscaling of the web tier to keep serving capacity and allow investigation
    • Cleared up the broken, partly provisioned instances that filled the autoscaling groups
    • Repaired provision-service so new web tier instances could be provisioned and enter service
    • AWS engineers increased the Transit Gateway capacity manually across all Availability Zones
    Action items
    • AWS reviews its Transit Gateway scaling algorithms for large packet-per-second increases
    • Request a preemptive upscaling of the Transit Gateways at the end of the next holiday season
    • Run the dashboard service instances in the same VPC as their database to remove the Transit Gateway dependency
    • Load test provision-service regularly
    • Reevaluate health-checking and autoscaling configurations so they cannot overload provision-service again
    Lessons

    Monitoring has to stay as independent as possible of the infrastructure it watches, or it fails when it is needed most. Here the dashboard and alerting services failed because they ran in a different VPC from their databases and so depended on the Transit Gateways. provision-service had been load tested before, but this event exceeded the earlier scale-ups.

  5. Symptoms

    On 2 November 2020 the Cloudflare API and dashboard were degraded for six hours and 33 minutes. The success rate of API queries dropped at times to 75%, and the dashboard was up to 80 times slower than normal, while Cloudflare's edge network kept working.

    Trigger

    At 14:43 UTC a network switch in a control plane data center partly failed: it kept LACP and BGP running but stopped forwarding some packets, and it recovered on its own six minutes later.

    Root cause
    Component
    Contributing factor
    Detection

    At 14:43 UTC alerts fired because the misbehaving switch was unreachable to pings. Engineers then saw that the primary authentication database was overwhelmed.

    Remediation
    • Shed load from the primary authentication database by slowing SSL certificate pushes to the edge, emails and other features
    • Moved API traffic that could use read replicas to the secondary data center by hand
    • Sent authentication calls fully back to the primary data center when the dashboard got worse
    • Rebuilt the first database replica, which put itself back into service at 21:20 UTC and returned performance to normal
    • Ramped the turned-down services back up so asynchronous processing could catch up
    Action items
    • Remove the cluster management limitation that requires rebuilding all replicas after a primary is promoted
    • Redesign the user sessions system so dashboard traffic can be steered between data centers
    • Change the auto-remediation configuration so a database replica is not promoted so quickly
    • Tune each system involved to be more resilient to failures of its dependencies
    Lessons

    Every system in the chain had redundancy and none failed completely; each only degraded, which made the chain of events much harder to model and foresee. Automating replica promotion so that it could trigger on a minute's notice had been a point of pride, but for at least one database a fast promotion can do more harm than the failure it answers. Most general-purpose cluster managers use Raft or Paxos rather than Byzantine fault tolerant protocols, accepting a rare failure mode in exchange for a protocol that is simpler to implement correctly and debug.

Check your cluster for this

These 24 cases involve BGP routing and Backbone network (WAN). kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause9

Configuration change5 cases

  1. IL-0394 A Cloudflare router in Miami leaked IPv6 BGP routes to peers and providers for 25 minutes, congesting the backbone
  2. IL-0339 Azure Front Door and Azure CDN users saw intermittent connection errors, timeouts and latency spikes for hours
  3. IL-0225 An IGP purge command made every Microsoft WAN router recompute routes, causing global latency, timeouts and packet loss
  4. IL-0461 Every rollout of Datadog's metrics query service on Kubernetes raised errors that the logs blamed on DNS
  5. IL-0361 Job searches on seek.com.au failed for 16 minutes as a Transit Gateway silently dropped 9001-byte packets
    SEEK2021

Capacity exhaustion5 cases

  1. IL-0564 Linode's Miami, Milan and Sao Paulo data centers had packet loss as traffic moved onto congested alternate paths
    Linode2025
  2. IL-0341 Traffic between Cloudflare and AWS us-east-1 had high latency, packet loss and origin failures for almost four hours
  3. IL-0440 Pods on Cybozu's Neco Kubernetes platform got frequent no such host and i/o timeout DNS errors from dropped packets
    Cybozu2024
  4. IL-0386 After a move to Google Cloud, Postgres connection timeouts and memcached i/o timeouts spiked on GKE nodes
  5. IL-0537 Sakura Cloud host servers repeatedly lost their storage connection, about five minutes per port switchover

Operator error1 case

Contributing factor
Organisation
  1. IL-0348 Scaleway's FR-PAR region lost public internet connectivity when one 100 Gbps backbone link was saturated

Dependency failure2 cases

Organisation
  1. IL-0257 canva.com went down for about 50 minutes when 1.5 million requests per second OOM-killed every API Gateway task
    Canva2024
  2. IL-0358 Packet Public Cloud locations had high latency and unreachable paths from routing loops and blackholed traffic
    Packet2019

Software defect4 cases

  1. IL-0347 About 25% of Scaleway FR-PAR-1 hypervisors lost VPC connectivity when both VPC BGP route reflectors got stuck
  2. IL-0529 New Google Cloud VMs and other instances came up without network connectivity in all zones after VPC controllers stopped
  3. IL-0336 AWS Direct Connect traffic into the Tokyo Region had packet loss and intermittent connectivity for about six hours
  4. IL-0222 Google Cloud US regions had heavy packet loss and some went unreachable after the network control plane was descheduled

Faulty deployment3 cases

  1. IL-0293 Cloud Bigtable in us-central1 had higher latency and connection errors for about 32 hours from low-rate packet loss
  2. IL-0530 Virtual router controllers in us-central1 ran out of memory in a loop, cutting networking for new and migrated VMs
  3. IL-0532 Azure Software Load Balancer sent packets of one flow to different backends, dropping Firewall and Private Link traffic

Hardware failure1 case

  1. IL-0540 Korea's local government administrative services and Government24 went down as a router port dropped most large packets

Cloud provider outage1 case

Organisation
  1. IL-0220 An overloaded AWS Transit Gateway dropped packets on 4 January 2021, and Slack's web tier saturated and went down
    Slack2021

DNS or network fault2 cases

  1. IL-0240 Cloudflare API requests failed and the dashboard slowed for hours after the authentication database lost its replicas
  2. IL-0590 F5 load balancers cached a path MTU of 296 after Rackspace reboots, and Mailgun connections failed intermittently