  1. Symptoms

    ByteDance's large language model training jobs on its MegaScale system, which runs on more than 10,000 GPUs, occasionally stalled or slowed down. The cause was network interfaces that flapped frequently.

    Trigger

    Network interfaces went down for several seconds and came back up, dropping every packet in transit.

    Root cause
    Component
    Contributing factor
    Detection

    MegaScale's monitoring system uses second-level monitoring to track link flapping and other NIC issues. When the RDMA traffic metrics carried in the training daemons' heartbeats drop sharply or fluctuate abnormally, the driver raises an alert for manual investigation, and if the traffic stops entirely it starts the fault recovery procedure automatically.

    Remediation
    • set NCCL's timeout threshold explicitly to a larger value than the default
    • tuned NCCL's retransmit timer and retry count for fast recovery under link flapping
    • enabled the adap_retrans feature on the NICs
    • applied lower-level quality control to NIC signal strength, AOC cable quality and switch-side signal strength
    Lessons

    A default NCCL timeout can be shorter than the few seconds an interface needs to come back from a flap, so a brief link loss becomes a failed collective and a stalled job. A larger timeout and faster retransmission give the link time to return, but the flapping itself came from physical link quality between NIC, AOC cable and switch, and quality control at that level reduced it.

  2. Symptoms

    This is a vulnerability report, not an outage, so nothing failed visibly. What an engineer can check is whether the Argo CD Redis server accepts connections without a password from a pod in another namespace, on port 6379 at the address kube-dns returns. In the default installation it did.

    Trigger

    Cycode Labs installed Argo CD with the default configuration on a new Amazon EKS cluster and connected to its Redis server from a low-privilege pod in another namespace, simulating a compromised pod.

    Root cause
    Component
    Contributing factor
    Detection

    Found by Cycode Labs security research, not by an operator.

    Remediation
    • Argo CD released 2.11.1, 2.10.10, 2.9.15 and 2.8.19 with an initialized password for the Redis server
    Lessons

    The hash that checks the cached manifests is computed without a secret key, so anyone who can write to Redis can recompute it and make Argo CD deploy an altered manifest. Cycode recommends upgrading to the fixed versions, checking that the argocd-redis-network-policy NetworkPolicy exists and that a CNI enforces it, using controller-based secret management instead of injecting secrets through Argo CD plugins so secrets never reach Redis, and running Argo CD on a dedicated cluster.

  3. Symptoms

    Customers of DigitalOcean Managed Kubernetes (DOKS) saw worker nodes go NotReady between 06:00 and 07:00 UTC and stay unavailable, taking down the services on them, until the nodes were replaced or rebooted; some nodes needed several replacements or reboots. The first sporadic reports on October 8 said replacing the node fixed it. The same thing happened again around 06:00 UTC on October 9, more widely and across many regions, and again on October 10. Only clusters on versions 1.27.6-do.0 and 1.28.2-do.0 were affected.

    Trigger

    A systemd timer in the DigitalOcean Debian image started apt upgrade daily at 06:00 UTC, with a random delay of up to 60 minutes.

    Root cause
    Component
    Contributing factor
    Detection

    Sporadic customer reports of failed worker nodes arrived at 07:43 UTC on October 8; internal incident response started at 07:10 UTC on October 9 after broader impact across regions.

    Remediation
    • Advised customers to replace or reboot affected worker nodes
    • Arranged SSH and console access to worker nodes while they were healthy, and live-debugged an affected node on October 10
    • Released a DaemonSet to all affected clusters that disables the apt upgrade systemd timer on every worker node
    • Released new node images without the auto-update process
    Action items
    • Disable the timer during node provisioning, then remove the DaemonSet from all clusters
    • Add a check to the internal conformance test suite for new cluster versions that the auto-upgrade process and other unwanted timers stay disabled
    • Support logging into worker nodes even when normal access paths are broken
    Lessons

    An operating system auto-update timer left enabled in a node image can change the kernel and systemd underneath Kubernetes, and a timeout that kills the upgrade half-way can leave a node without networking. Failures that start at the same time every day point to a scheduled job on the nodes, and systemd timers belong on that list next to cron jobs. When the failure takes out a node's network, an investigation that depends on logging into the node stalls; access paths that work while the node is broken shorten diagnosis.

  4. Symptoms

    Request latency from the Temporal Server History service, the service that starts workflow executions and records their progress, was higher and less steady than it should be on a self-hosted Kubernetes deployment. The CPU dashboard showed the history pods using less than 60 percent of their CPU, yet the same pods were being throttled.

    Trigger

    Normal load on History pods that had a CPU limit of 2 cores on 8-core nodes, with the Go runtime's GOMAXPROCS left at its default of one per node core.

    Root cause
    Component
    Contributing factor
    Detection

    A Prometheus query for CPU throttling showed the history pods throttled although their CPU usage read under 60 percent.

    Remediation
    • set the GOMAXPROCS environment variable to 2 to match the 2-core CPU limit
    Action items
    • Set GOMAXPROCS automatically from the Kubernetes CPU limit, from Temporal release 1.21.0
    Lessons

    A CPU usage graph averaged over 15 seconds or more can sit far below 100 percent while a container is being throttled, so throttling needs its own metric. A Go program in a container should have GOMAXPROCS matched to its CPU limit, or to its CPU request when it has no limit. The author recommends not using CPU limits at all.

  5. Symptoms

    On a Friday afternoon a tenant of SCHIP, Adevinta's multi-tenant Kubernetes runtime, reported a spike of HTTP 5xx errors in some of its services. The drops in quality of service came back periodically through the following days, each one short, and were reported mostly around midnight.

    Root cause
    Component
    Contributing factor
    Detection

    A tenant reported a spike of HTTP 5xx errors in some of its services; the DNS Latency SLI had already been degraded for some time without being acted on.

    Remediation
    • raised the dnsmasq concurrent query limit from 150 to 1500
    • added a CoreDNS header block that sets the ra and aa flags and clears rd, so dnsmasq caches cluster.local answers
    • configured dnsmasq on each node to answer NXDOMAIN for unresolvable search-domain names instead of forwarding them to CoreDNS
    • changed the fluent-bit log router hostname to a fully qualified name
    • asked the affected tenants to use fully qualified names for internal calls
    Lessons

    The DNS Latency SLI had shown the problem long before anyone looked at it. An SLO only protects you when its SLIs are trusted and a drop is investigated. The investigation took a month partly because several on-call groups worked on it separately, without one place for observations and hypotheses, and sometimes chased hypotheses already discarded. Disprove one hypothesis before starting the next, and collect data the metrics system lacks: DNStop showed the garbage lookups that no dashboard did. With ndots:5, short service names multiply DNS traffic; a node-local cache only helps if it can cache the cluster DNS answers at all.

Check your cluster for this

These 47 cases involve Kubernetes API server and kubelet. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause11

Capacity exhaustion17 cases

  1. IL-0071 Worker node running out of inodes while disk space looked fine, because containerd kept a full node_modules tree in each of several image layer snapshots
  2. IL-0048 DNS lookups timed out in a large EKS cluster when CoreDNS hit the 1024 packets-per-second link-local limit, driven by sudo hostname lookups
  3. IL-0006 VPC subnets ran out of IP addresses because the AWS VPC CNI kept IPs on full nodes, and WARM_IP_TARGET changes then blocked pod starts after every pod deletion
    Neon2025
  4. IL-0170 During a Lunar New Year event, traffic more than three times normal filled the nf_conntrack table on the EKS node running the Istio ingress gateway, dropping packets and taking down Backpackr's web and app services
  5. IL-0027 All CoreDNS pods landed on one node, the node ran out of memory, and DNS for the whole service went down
  6. IL-0204 An etcd memory spike overloaded the control plane of a Render Frankfurt cluster, and DNS then failed because CoreDNS ran on the rebooted control plane nodes and could not start without the API server
    Render2024
  7. IL-0007 The AWS VPC CNI could not assign IP addresses to pods as an EKS cluster ran out of IPv4 space
  8. IL-0046 Prometheus restarted again and again because its WAL replay took longer than the startup probe allowed
  9. IL-0028 Temporal History service latency rose because its pods were CPU-throttled while CPU usage read below 60 percent
  10. IL-0195 The kube-apiservers of a cluster with more than 200 nodes ran out of memory and crashed one after another under mass LIST requests from Cilium agents
    Palark2023
  11. IL-0194 After a kube-apiserver restart, pod LIST requests from every pod of a Vector DaemonSet nearly tripled etcd memory and restarted all master nodes
    Palark2023
  12. IL-0015 A GKE cluster's /16 pod address range ran out at 256 nodes, leaving new pods Pending and node scale-ups failing
  13. IL-0033 Uneven load across kube-dns pods and a DNS packets-per-second limit pushed service latency to 20 seconds
    Airbnb2019
  14. IL-0002 CI builder pods could not get AWS IAM credentials because kubelet fell minutes behind its API rate limit
  15. IL-0076 Kubernetes masters went down after Dex filled etcd with AuthRequest objects and deleting its namespace started an endless list-and-timeout loop
  16. IL-0001 Cluster-wide DNS outage after CoreDNS pods were OOM-killed again and again under a burst of DNS queries
  17. IL-0040 Parallel Helm installs saturated small gp2 root volumes on a kops cluster and left all three workers NotReady with the kubelet or Docker down

Dependency failure3 cases

  1. IL-0023 A training run crashed with an NCCL timeout after one InfiniBand port went down once and recovered
  2. IL-0187 A brief Spring Cloud Config Server downtime failed every client application's liveness probe, because the actuator health check included the config server, and Kubernetes restarted the pods in a kill loop
  3. IL-0103 During an EKS node AMI update, Istio sidecars crash-looped because hundreds of pods restarting at once overloaded the external certificate authority behind istiod

Certificate or credential expiry2 cases

Organisation
  1. IL-0183 kubeadm's one-year leaf certificates expired, so kube-apiserver could not reach etcd, restarted in a loop and left the cluster unreachable
  2. IL-0107 Kyverno stuck in a crash loop behind a webhook with failurePolicy fail blocked every change to Kubernetes Service objects for 88 minutes
    DFDS2022

Faulty deployment2 cases

  1. IL-0188 Rolling updates on EKS returned 502 errors for about 30 seconds because Kubernetes deleted old pods as soon as new pods passed readiness, before the ALB had marked the new pod targets healthy
  2. IL-0020 During an EKS 1.30 upgrade the descheduler tried to reschedule every pod on the cordoned nodes at once and production workloads went down

Software defect6 cases

  1. IL-0104 After a CoreDNS pod was OOMKilled, the talk names three causes: Istio's aggressive DNS cache refresh on one reused client port, kube-proxy not cleaning up conntrack entries of terminated pods, and the 2-minute UDP conntrack timeout
  2. IL-0053 Unauthenticated ingress-nginx admission webhook let anyone on the pod network run code and read every Secret in the cluster (IngressNightmare, CVE-2025-1974)
    Wiz2025
  3. IL-0065 Any pod could take over the cluster by rewriting Argo CD's unauthenticated Redis cache (CVE-2024-31989)
    Cycode2024
  4. IL-0190 Cortex distributors kept a stuck connection to a dead etcd leader after a Kubernetes upgrade terminated its node, failing writes to Hosted Prometheus for 12 minutes
  5. IL-0050 Pods on Kubernetes failed to resolve an external Redis hostname because of ndots:5, the musl resolver in Alpine images, and Netty's DNS resolver
  6. IL-0072 High etcd write latency made the API servers return stale data, and the production cluster flipped between two views of its state

DNS or network fault6 cases

  1. IL-0128 Network interfaces that dropped for a few seconds made NCCL time out and stalled or slowed LLM training on a cluster of more than 10,000 GPUs
  2. IL-0083 Intermittent 5xx errors in a multi-tenant Kubernetes cluster came from internal DNS: the node-local dnsmasq hit its 150 concurrent query limit, did not cache cluster.local answers, and ndots search lookups flooded CoreDNS
  3. IL-0178 On EKS, HPA scale-in returned 502 errors because containers stopped before their pod IPs left the Service endpoints, and after blue/green switches conntrack kept sending established connections to deleted pods behind an instance-mode ALB
  4. IL-0056 Calls from EKS pods to services behind an NLB in another VPC failed intermittently because the AWS VPC CNI did source NAT on the node
  5. IL-0057 Higher p99 latency after moving a reverse proxy to EKS, from outgoing connections delayed by a SNAT conntrack race
    Prezi2019
  6. IL-0047 Pod-to-pod requests delayed by 5, 10 or 15 seconds because of DNS lookups lost to a conntrack race

Configuration change7 cases

  1. IL-0153 DOKS worker nodes went NotReady at 06:00 UTC on three days because a systemd timer in the Debian image ran apt upgrade and killed it mid kernel upgrade, breaking node networking
  2. IL-0109 A retried node rollover on a DFDS EKS cluster set the Auto Scaling group back to 15 instances, and the default termination policy removed every healthy worker node, leaving the cluster with no nodes
    DFDS2023
  3. IL-0191 A label selector accidentally added to the Loki distributor Service matched only the new pods of a rollout, which took all write traffic, were OOM-killed and stalled the rollout
  4. IL-0189 A JVM service moved from EC2 to Kubernetes answered up to ten times slower because KIAM's 15-minute credentials made the AWS Java SDK fetch new credentials on every request
  5. IL-0052 A cryptocurrency miner ran on every node of the development and staging clusters through a public, unauthenticated Weave Scope dashboard
  6. IL-0035 Worker nodes went NotReady after a new ElastAlert rule without memory limits used up node memory
    NU.nl2019
  7. IL-0055 A failing CronJob with the default concurrency policy piled up thousands of restarting pods and took down a cluster
    Target2018

Breaking change in an upgrade1 case

Organisation
  1. IL-0198 An automatic Ubuntu security update restarted systemd-networkd, which flushed the IP rules Cilium relied on and cut more than 60 percent of Datadog's Kubernetes nodes off the network across regions and cloud providers

Hardware failure1 case

Organisation
  1. IL-0125 A GPU died about once a week during a 176B-parameter training run, and sometimes the job hung instead of exiting, so SLURM never restarted it

Operator error1 case

Organisation
  1. IL-0054 All ingress traffic lost while draining a GKE node pool because the load balancer only targeted new nodes without ingress-nginx pods

unknown1 case

Organisation
  1. IL-0059 Single-master Kubernetes control plane kept dying because the kubelet restarted a healthy etcd on a failing kubeadm liveness probe