  1. Symptoms

    From 10:03 UTC on 29 September 2026, requests to Azure OpenAI Service, Foundry Agent Service, Foundry Models and Azure AI services in Sweden Central failed intermittently, took longer, or returned HTTP 500 and 503 errors. At 10:17 UTC service monitoring raised an alert on elevated failure rates for Azure OpenAI Service requests in the region.

    Trigger

    At about 09:38 UTC a planned deployment of an internal service in Sweden Central cleared that service's caches during the region's peak traffic hours.

    Root cause
    Component
    Contributing factor
    Detection

    Service monitoring detected elevated failure rates for Azure OpenAI Service requests in the region at 10:17 UTC and alerted the engineering teams; engineers were engaged at 10:28 UTC.

    Remediation
    • reconfigured the backend service's automated health check so it no longer depended on remote connectivity, which stopped the restart loop
    Action items
    • Reconfigure the backend service's automated health check so it no longer depends on connectivity to its database layer
    • Add monitoring and alerting on the load and latency of the caching layer used by the backend service
    • Update troubleshooting and procedural guidance for connection exhaustion scenarios for on-call engineers
    • Add throttling and rate limiting to protect the backend service from sudden traffic increases (estimated October 2026)
    • Increase the resource capacity of the caching layer used by the backend service across regions (estimated October 2026)
    • Improve diagnostic metrics and automated detection to identify such issues more quickly (estimated October 2026)
    • Partition the caching layer used by the backend service to increase its throughput (estimated December 2026)
    Lessons

    A health check that depends on a remote dependency turns a dependency problem into a restart loop: instances that cannot reach the database are killed, the remaining ones take more load and retries, and adding instances or resources does not help until the check itself is changed. Clearing a cache during peak traffic can multiply load on the backend behind it, especially when cache-read defects let lookups bypass the cache. Connection exhaustion was hard to see because the existing network and diagnostic metrics did not show it.

  2. Symptoms

    A Kubernetes worker node paged with NodeFilesystemFilesFillingUp, the node_exporter mixin alert that predicts a filesystem will run out of inodes. The engineer checked disk space first: df -h showed the root filesystem 83% used, 103G used and 22G available. df -i showed inodes 67% used, 11M used and 5.3M free.

    Trigger

    Several versions of a single-stage Node.js image, each shipping more than 40,000 files, were held on the node; containerd unpacked every layer with a distinct digest into its own snapshot, each with a full copy of node_modules.

    Root cause
    Component
    Contributing factor
    Detection

    The NodeFilesystemFilesFillingUp alert from the node_exporter mixin fired on the predicted inode trend while inode use was at 67%.

    Action items
    • Build the image in multiple stages so the final image contains only the compiled assets
    • Add a flat alert on root filesystem inode use above 80% for 30 minutes alongside the predictive alert
    • Put a Prometheus query on a dashboard that shows, per node, inode usage minus disk usage, sorted from the highest
    • Remove unused images from nodes with crictl rmi --prune to free old snapshots
    Lessons

    kubelet's background cleanup works on bytes only. A workload heavy in small files gets no early intervention for inodes, and the first thing kubelet does at 5% free inodes is evict pods. Watch inode use on nodes separately from disk use, and keep dependency trees out of runtime images.

  3. Symptoms

    From 22:47 UTC on 25 August 2026 the Buildkite web interface, REST API, Agent API, job queue and notifications stopped working for every customer. No one could create a build from the UI or the REST API, job dispatch was delayed, and some builds that were already running when the outage began stayed stuck until the services recovered.

    Trigger

    At 22:44 UTC an application deploy created a surge of new pods, which used up the free capacity on the existing nodes and made the EKS cluster scale out. Background worker pools with unusually high maximum replica counts were scaling out at the same time and kept asking for more pods while new nodes were still being provisioned. Together they produced an unusually high rate of change in applications, network endpoints and nodes, and with it a sudden rise in demand on CoreDNS.

    Root cause
    Component
    Contributing factor
    Detection

    The first status post, at 22:55 UTC, eight minutes after the outage began, said something had gone wrong, and at 23:05 UTC the status page said a sitewide outage was being investigated. CoreDNS query duration had been rising as the cluster grew, but a defect in a key monitoring query and too little monitoring of query volume meant this went unnoticed before the outage.

    Remediation
    • paused further application deploys
    • scaled CoreDNS from three to twelve pods
    • raised each CoreDNS pod's memory limit from 512 MiB to 2 GiB
    • expanded the system node pool that runs CoreDNS
    Action items
    • Increase immediate CoreDNS headroom: twelve pods instead of three, a 2 GiB memory limit instead of 512 MiB, and a larger system node pool
    • Enable EKS-managed CoreDNS autoscaling with a tested minimum replica count and enough capacity to spread the replicas across nodes and availability zones
    • Add direct alerts on CoreDNS query duration, query volume, goroutine growth, memory pressure, OOM restarts and available replicas, and track longer-term trends in capacity planning
    • Find other cluster-critical services that lack tested capacity, direct alerting, spread across failure domains, and either safe autoscaling or documented static headroom, and fix them
    Lessons

    A CoreDNS deployment sized once and left at a fixed size can carry a growing cluster for months and then fail on the first burst of churn it cannot absorb. When query processing slows, pending queries take up memory, the pods hit their limits and restart, and client retries keep the service down after the restart. Server-side DNS query duration and volume need their own alerts: here client-side latency was masked by unrelated application speed-ups, and a broken monitoring query hid the server-side trend. Maximum replica counts raised as a temporary measure remove the cap that normally stops runaway scaling when new nodes are slow to arrive.

  4. Symptoms

    On 19 August 2026 the first equipment-level signs in Nebius's us-central1 region appeared around 09:40 UTC: the InfiniBand fabric degraded and GPU over-temperature alerts began to accumulate. Customer reports followed shortly after 10:00. At 10:15 on-call engineers were paged on critical component temperature alerts, and the incident was declared at 10:21.

    Trigger

    A storm-related event at the data center building took the building management system offline and shut down the chilled-water cooling loop.

    Root cause
    Component
    Contributing factor
    Detection

    No facility-level alert fired, because the storm also disabled the building management system that monitors the facility. Engineers acted on component over-temperature alerts that paged on-call at 10:15 UTC, after InfiniBand degradation, GPU over-temperature alerts and customer reports; the temperature rise from about 09:15 was visible on dashboards but had no alert.

    Remediation
    • had the facility operator switch cooling to manual bypass mode and opened rack rear doors to vent heat
    • re-energised tripped racks, control-plane racks first
    • restored the regional infrastructure control plane by manual intervention
    • restarted block-storage host components to clear stale disk attachment state
    • raised the VM recovery rate limits by hand for the region-scale recovery
    • started the affected Managed Kubernetes control-plane instances by hand
    • applied a controlled stop and start to control-plane instances whose data disk had been left unattached
    • identified and started 104 customer VMs that the incident had stopped
    Action items
    • Complete a joint resilience review with the facility operator covering redundancy of facility-management and monitoring systems, cooling that keeps running when those fail, electrical protection of cooling equipment and on-site response
    • Add facility-level environmental alerting on cooling plant state and room temperature trend that pages on-call independently of the building management system
    • Set up a documented emergency escalation path with the facility operator, with an on-call contact tree and guaranteed response times
    • Define an emergency heat-load reduction procedure with criteria, ownership and mechanics for shutting down or degrading workloads during a cooling loss
    • Establish a dependency-ordered region cold-start procedure with clear ownership for each service layer
    • Run regular region-scale recovery drills that cover VMs, storage attachments and Managed Kubernetes clusters
    • Fix the disk-attachment bug that extended the Managed Kubernetes outage and deploy the fix to all production regions
    • Improve the recovery policies Compute users can configure, and move all Managed Kubernetes control-plane nodes to the improved policy
    • Automate reconciliation of stale storage attachment state after abrupt host failures
    • Remove in-region dependencies from monitoring startup and recovery, and extend cross-region monitoring
    • Make regional health checks used for global traffic management reflect real service availability
    Lessons

    Facility monitoring that runs on the same system it watches goes silent in exactly the failure it should report, and with no alert on the room temperature trend there was no practical window to shed heat load in a controlled way. A cold start of a whole region exercised recovery paths built for isolated failures: single-attempt VM recovery, conservative rate limits and stale disk attachments all needed manual work. The longest part of the outage was restoring customer resources, Managed Kubernetes control planes above all, so Nebius is extending its recovery drills to that layer.

  5. Symptoms

    Seven hours into a distributed training run on Databricks AI, the job failed with an NCCL timeout.

    Trigger

    A single InfiniBand port used for RDMA NCCL collectives went down once and recovered.

    Root cause
    Component
    Contributing factor
    Detection

    The training job crashed with the NCCL timeout. The continuous health checks, which watched InfiniBand port flapping by count, had not flagged the single flap.

    Remediation
    • Tuned the NCCL_IB_TIMEOUT defaults to be more resilient to short port-down windows
    • Used the port-down signal to crash the job and restart it from a checkpoint instead of waiting for the watchdog
    • Fed the investigation into gpu-monitor, whose RDMA fabric port-down check is thresholded on cumulative downtime rather than flap count
    Action items
    • Tune the NCCL_IB_TIMEOUT defaults to be more resilient
    • Crash and restart the job from a checkpoint on the port-down signal instead of leaving GPUs idle until the watchdog fires
    • Threshold RDMA fabric port-down detection on cumulative downtime, not flap count, in gpu-monitor
    Lessons

    For training impact the signal that matters is cumulative port downtime, not the number of flaps: one long enough flap can crash a multi-day run. NCCL_IB_TIMEOUT, with an effective default of about seven seconds, decides the outcome long before the PyTorch watchdog timeout does. Health checks need to cover the whole node lifecycle: active checks before workloads start, passive checks for silent degradation under load, and periodic multi-node NCCL fabric checks in between.

Check your cluster for this

These 43 cases involve Kubernetes API server and kubelet. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause9

Faulty deployment3 cases

  1. IL-0136 A deployment that cleared an internal service's caches at peak traffic sent 20 times the normal load to the Azure OpenAI metadata backend in Sweden Central, and health checks that depended on its database restarted instances in a loop for almost six hours
  2. IL-0188 Rolling updates on EKS returned 502 errors for about 30 seconds because Kubernetes deleted old pods as soon as new pods passed readiness, before the ALB had marked the new pod targets healthy
  3. IL-0086 A deployment meant for a CircleCI test Kubernetes cluster also removed Traefik and Calico resources from the production cluster, taking down the CircleCI UI and runner.circleci.com

Capacity exhaustion13 cases

  1. IL-0071 Worker node running out of inodes while disk space looked fine, because containerd kept a full node_modules tree in each of several image layer snapshots
  2. IL-0102 CoreDNS pods on a production EKS cluster ran out of memory under a burst of new pods, endpoints and nodes, taking down the Buildkite web UI, APIs and job dispatch
  3. IL-0137 Training initialisation on a 60-node NVIDIA B200 cluster took more than 8 hours instead of minutes because fragmented small random I/O from all nodes saturated the metadata service of the VAST Data NFS storage
  4. IL-0181 A traffic spike from an external community post pushed product API pods into CPU throttling under a 1-core limit, and an e-commerce product page slowed down while every pod stayed Running
    Kevin2026
  5. IL-0170 During a Lunar New Year event, traffic more than three times normal filled the nf_conntrack table on the EKS node running the Istio ingress gateway, dropping packets and taking down Backpackr's web and app services
  6. IL-0085 A control plane node of Magic Pages' Kubernetes cluster on Hetzner Cloud ran out of memory, the cluster's own calls then used up the Hetzner API rate limit, and all customer websites were down for about 7.5 hours
  7. IL-0110 A Grafana Agent pod's high memory use and crash-looping Hangfire pods drove a Kubernetes node into system OOM and NotReady, twice in one day
    DFDS2024
  8. IL-0043 Application logs missing in Kibana after a newer Fluent Bit version changed its chunk drop strategy
  9. IL-0028 Temporal History service latency rose because its pods were CPU-throttled while CPU usage read below 60 percent
  10. IL-0070 Critical pods on core nodes evicted when Prometheus began scraping about 200 nodes after a dask-gateway scale-up
    2i2c2023
  11. IL-0075 Kubernetes API servers pegged on CPU when the cluster grew to about 290 nodes, traced to Datadog agents polling the API
  12. IL-0001 Cluster-wide DNS outage after CoreDNS pods were OOM-killed again and again under a burst of DNS queries
  13. IL-0040 Parallel Helm installs saturated small gp2 root volumes on a kops cluster and left all three workers NotReady with the kubelet or Docker down

Dependency failure4 cases

  1. IL-0133 A storm shut down cooling at Nebius's us-central1 data center, and a disk hot-plug bug kept Managed Kubernetes control planes down for hours after power returned
    Nebius2026
  2. IL-0023 A training run crashed with an NCCL timeout after one InfiniBand port went down once and recovered
  3. IL-0025 Failed boots, InfiniBand link flapping, NCCL hangs and throughput sags while bringing up a 4,088-GPU H100 training cluster
    Imbue2024
  4. IL-0039 New Kubernetes worker nodes could not join any cluster because a package URL hardcoded in kops nodeup broke

Configuration change10 cases

  1. IL-0200 Newly provisioned Kubernetes nodes ran an incompatible etcd version and broke cluster consensus in several GitHub production clusters, causing 5XX errors on Git operations and page loads
    GitHub2026
  2. IL-0005 A new telemetry service overloaded the Kubernetes API servers of large clusters and broke DNS-based service discovery for all OpenAI services
    OpenAI2024
  3. IL-0068 Anonymous access to the Kubernetes API server used to plant a ClusterRoleBinding backdoor and a cryptominer DaemonSet
  4. IL-0116 A CNI configuration change incompatible with a hardware variant that exists only in production cut network connectivity in an OpenAI GPU cluster and took text-davinci-003 fully down
    OpenAI2023
  5. IL-0009 A duplicated generated name made Argo CD replace the InfluxDB Cloud production Application and delete the whole production environment
  6. IL-0111 Switching the main Kubernetes ingress controller from Traefik v1 to v2 stopped X-Forwarded headers being passed, which broke the Okta login flow for every service using Okta and stopped DFDS online bookings for over an hour
    DFDS2021
  7. IL-0108 An Alcide admission controller applied to the production cluster during a workshop made create and update requests on Deployments time out
    DFDS2020
  8. IL-0008 An unresponsive OPA validating webhook crash-looped the API server during a GKE master upgrade, and node auto-repair then recreated every node
  9. IL-0052 A cryptocurrency miner ran on every node of the development and staging clusters through a public, unauthenticated Weave Scope dashboard
  10. IL-0035 Worker nodes went NotReady after a new ElastAlert rule without memory limits used up node memory
    NU.nl2019

Software defect8 cases

  1. IL-0124 Capacity changes queued while a circuit breaker was engaged ran all at once when it was released, taking multiple OpenAI inference engines out of service and raising API error rates
    OpenAI2026
  2. IL-0022 Three overlapping infrastructure bugs (context-window misrouting, TPU output corruption and an XLA top-k miscompilation) degraded Claude's responses
  3. IL-0138 A failed Nvidia driver build left broken kernel packages on the only Kubernetes master node, which hit a kernel panic on reboot after a power outage and took the homelab cluster down for six days
  4. IL-0112 The daily node rollover put DFDS's EKS nodes on an AMI later recalled for a kernel issue, causing "PLEG is not healthy" NodeNotReady flaps and pod network timeouts
    DFDS2022
  5. IL-0032 Mutating admission controller generated broken JSON patches, silently blocking deploys for a week until a production service ran down to two pods
    Airbnb2020
  6. IL-0041 fluent-bit silently stopped shipping application logs from one node to Elasticsearch
  7. IL-0012 CPU limits and an unpatched kernel CFS quota bug throttled multi-threaded services into stalls, failed health checks and timeouts
    Omio2020
  8. IL-0003 linkerd lost Kubernetes service discovery after an etcd reconfiguration, and restarting every linkerd instance turned failed payments into a full platform outage
    Monzo2017

Breaking change in an upgrade2 cases

Organisation
  1. IL-0203 A routine Kubernetes cluster system update made the AWS Load Balancer Controller fail, so new pods were never registered with the ALB and Honeycomb's EU1 ingest and UI went down once the last old pods were replaced
  2. IL-0060 Kubernetes 1.24 upgrade removed the master node label that Calico route reflectors selected on, dropping all pod routes and taking Reddit down for 314 minutes
    Reddit2023

Certificate or credential expiry1 case

Organisation
  1. IL-0107 Kyverno stuck in a crash loop behind a webhook with failurePolicy fail blocked every change to Kubernetes Service objects for 88 minutes
    DFDS2022

Cloud provider outage1 case

Organisation
  1. IL-0205 The GKE cluster autoscaler could not add nodes to GitLab.com's production cluster because Google Cloud ran out of SSD persistent disks in us-east1
    GitLab2021

unknown1 case

Organisation
  1. IL-0059 Single-master Kubernetes control plane kept dying because the kubelet restarted a healthy etcd on a failing kubeadm liveness probe