  1. Symptoms

    At 01:04 CET on 13 February 2024, the Kubernetes API behind Scaleway's managed Kubernetes services Kapsule and Kosmos in the Paris region (FR-PAR) spiked in RAM and CPU use and ran out of memory. Nodes in FR-PAR could no longer authenticate to their control plane, and some of them went "Not Ready". Customers on both shared (mutualized) and dedicated environments were affected.

    Trigger

    A new Kubernetes release was made available to all users on 12 February 2024, and during the night of 12 to 13 February many clusters triggered their auto-upgrade at the same time.

    Root cause
    Component
    Contributing factor
    Detection

    The timeline's first entry, at 01:04 CET, records the Kubernetes API's RAM and CPU spikes and out-of-memory state, with nodes unable to authenticate to their control plane and some becoming "Not Ready". The first recorded action, 42 minutes later at 01:46, was to increase the resources allocated to the API.

    Remediation
    • increased the resources allocated to the Kubernetes API at 01:46 and again at 02:20
    • applied API traffic restrictions at 02:30 to smooth the incoming traffic
    • removed the traffic restrictions progressively in 50-100 batches from 03:20
    • ran a script at 03:40 to replace the failing nodes created during the congestion
    • rolled back to the former node authentication mechanism, first on a subset of clusters from 15:45 and on all clusters by 19:41 on 19 February
    • disabled cluster upgrade and configuration update features until 10:30 on 20 February
    Action items
    • Increase the resources allocated to the Kubernetes API
    • Roll back to the former node authentication mechanism
    • Implement a local authentication cache on nodes
    • Rework the resource allocation strategy to behave better under load spikes
    • Add new request queuing mechanisms for Kubernetes
    • Separate the different components to reduce side effects under high load or failure
    • Monitor selected metrics closely to identify anomalous patterns earlier
    • Refund customers who deployed nodes during the incident but could not use them normally
    Lessons

    Letting many clusters auto-upgrade at the same moment after a release turns routine upgrades into one coordinated load spike on the shared Kubernetes API. A node authentication mechanism that retries without letting up turns a slow API into an unavailable one, and auto-healing that replaces NotReady nodes amplifies the problem. The congestion pattern had already appeared three weeks earlier, and short-term mitigations did not stop it from recurring, so Scaleway rolled back the new authentication mechanism. Scaleway notes that as the number of customer clusters and nodes grows sharply, traffic control mechanisms have to improve to prevent congestion.

  2. Symptoms

    At 23:48 CET on 24 January 2024 the Scaleway Kubernetes API for the FR-PAR region ran out of memory. At the same minute Scaleway saw requests to its API Gateway spike.

    Trigger

    Simultaneous deployments in the FR-PAR region pushed the Scaleway Kubernetes API out of memory.

    Root cause
    Component
    Contributing factor
    Detection

    Increased load on the API Gateway was detected at 23:48, the minute the incident began, and the incident was escalated to on-call engineers at 00:00:10.

    Remediation
    • raised the memory limit and garbage collection thresholds of the Kubernetes managed services
    • deployed additional replicas of key services
    • purged the registry cache and monitored the clusters as they stabilised
    • adjusted service configurations after the incident to keep the platform stable
    Action items
    • Implement a local authentication cache
    • Further develop node authentication
    • Enhance monitoring, adjust rate limiting strategies and improve incident response protocols
    Lessons

    Because the Kubernetes API also handled node authentication, its memory exhaustion made some nodes NotReady, and the endless retries of those nodes added load on the API Gateway. Scaleway plans a local authentication cache and further work on node authentication.

  3. Symptoms

    Standard alerting paged Honeycomb's on-call engineers about the performance and stability of event ingestion, and the automated load-shedding mechanisms tripped and sent further notifications. The status page described a higher than normal error rate and response time on the ingestion service.

    Trigger

    An abnormally large number of queries arrived from many separate connections within a few minutes.

    Root cause
    Component
    Contributing factor
    Detection

    Standard alerting notified the on-call engineers about ingestion performance and stability, and the automated load-shedding mechanisms added notifications when they tripped. The first status post, about alerts on a higher than normal error rate and response time, went up at 18:28 PST (02:28 UTC), 13 minutes after the 02:15 UTC start.

    Remediation
    • Scaled the ingest fleet up manually and aggressively
    • Cut off most ingest for a few minutes so the ingest hosts could come back with enough capacity
    • Temporarily lowered the rate limits for the most aggressive traffic sources until their traffic subsided
    Action items
    • Keep the ingest fleet scaled up to prevent a repeat while longer-term fixes are worked on
    • Decide on the projects that will address these failure paths
    Lessons

    Load shedding and auto-scaling were in place, yet a burst that arrived faster than the cache could spread its writes still took the ingest hosts down. During recovery, Kubernetes' crash loop back-off worked against the operators: the hosts that had failed stayed offline while the fleet needed every host. Clients that retry whole OTel batches after a partial drop can multiply traffic many times over, so per-source rate limits were what finally stabilised ingest.

  4. Symptoms

    The graph of WebSocket connections to messaging-hub, the messaging platform used by the Japanese food delivery service Demaecan, showed sudden deep drops even outside peak traffic. The drops kept coming back at irregular intervals. Messages still reached clients, because messaging-hub switches to Firebase Cloud Messaging when a WebSocket is gone.

    Trigger

    Another service that shared the same L7 load balancer deployed its own load balancer configuration in the Verda dashboard, which reloaded HAProxy; 30 minutes later, at the hard-stop-after limit, the old HAProxy process exited and closed every WebSocket connection it still held.

    Root cause
    Component
    Contributing factor
    Detection

    The developer noticed deep, sudden drops in the WebSocket connection graph that were not tied to peak traffic and kept recurring irregularly. The Nginx packet drops were found through network monitoring.

    Remediation
    • separated the Merchant system's token issuance API into its own deployment so reconnect traffic did not delay other Merchant APIs
    • scaled out Nginx with pod anti-affinity and a label selector so each pod ran on a different node, which stopped the nf_conntrack packet drops
    • raised Ingress Nginx proxy-read-timeout and proxy-send-timeout and the load balancer timeout to 3600s, which did not stop the drops
    • moved messaging-hub from the shared L7 load balancer to an L4 load balancer, which ended the WebSocket drops
    Lessons

    A reload of a shared load balancer by a different team can cut long-lived connections, and with hard-stop-after the cut comes 30 minutes later, far from the change that caused it. The author's lesson is not to narrow the scope of the search too early: trusting that the infrastructure was fine kept the investigation inside the team's own systems for days. A reconnect wave from many WebSocket clients can overload the systems that issue connection tokens and fill nf_conntrack on proxy nodes. Scaling Nginx out only helps for conntrack if the pods land on different nodes, and anti-affinity leaves extra replicas Pending once they outnumber the nodes. That messaging-hub problems can still load the connected systems remains an open problem.

  5. Symptoms

    From 03:03 US/Pacific on 14 June 2022, calls to the GKE API in us-central1 through gcloud and the Google Cloud Console were slow and returned errors. Retrying sometimes succeeded.

    Trigger

    An unexpected increase in backend traffic to the GKE API in us-central1.

    Root cause
    Component
    Contributing factor
    Remediation
    • scaled up the GKE control plane to handle the increased traffic
    Lessons

    Client retries against an overloaded management API add to the overload. When the cloud provider's control plane is degraded, running workloads may be fine while cluster operations fail, and the status page offered no workaround beyond advising customers to use another region if they could.

Check your cluster for this

These 16 cases involve Application database and In-memory cache. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause4

Faulty deployment1 case

Organisation
  1. IL-0136 A deployment that cleared an internal service's caches at peak traffic sent 20 times the normal load to the Azure OpenAI metadata backend in Sweden Central, and health checks that depended on its database restarted instances in a loop for almost six hours

Capacity exhaustion10 cases

  1. IL-0102 CoreDNS pods on a production EKS cluster ran out of memory under a burst of new pods, endpoints and nodes, taking down the Buildkite web UI, APIs and job dispatch
  2. IL-0100 PostHog's feature flags pods were packed onto Kubernetes nodes that were too small for their CPU requests, and CPU saturation above 90% caused three outages in ten days through Redis overload, connection pool exhaustion and slow queries
  3. IL-0006 VPC subnets ran out of IP addresses because the AWS VPC CNI kept IPs on full nodes, and WARM_IP_TARGET changes then blocked pod starts after every pod deletion
    Neon2025
  4. IL-0085 A control plane node of Magic Pages' Kubernetes cluster on Hetzner Cloud ran out of memory, the cluster's own calls then used up the Hetzner API rate limit, and all customer websites were down for about 7.5 hours
  5. IL-0168 Simultaneous cluster auto-upgrades overloaded Scaleway's Kubernetes API, and a node authentication retry loop kept Kapsule and Kosmos nodes NotReady in FR-PAR
  6. IL-0169 The Scaleway Kubernetes API in FR-PAR ran out of memory under simultaneous deployments, and because it also handled node authentication, Kapsule and Kosmos nodes went NotReady
  7. IL-0202 A burst of queries and database writes exhausted connection pools and memory on Honeycomb's ingest hosts, and Kubernetes crash-loop back-off kept failed hosts offline so ingest capacity stayed too low to recover
  8. IL-0140 The GKE API in us-central1 returned errors and high latency for 3 hours 19 minutes after an unexpected rise in backend traffic that client retries made worse
  9. IL-0076 Kubernetes masters went down after Dex filled etcd with AuthRequest objects and deleting its namespace started an endless list-and-timeout loop
  10. IL-0001 Cluster-wide DNS outage after CoreDNS pods were OOM-killed again and again under a burst of DNS queries

Configuration change3 cases

  1. IL-0063 VPN outage after recreating a Redis StatefulSet restarted the whole Redis cluster without readiness checks
  2. IL-0177 WebSocket connections to LINE's messaging-hub on Kubernetes dropped all at once whenever another service's change reloaded a shared HAProxy L7 load balancer, and the reconnect wave overloaded a token API and filled nf_conntrack on Nginx
    LINE+2022
  3. IL-0004 A new default pod priority let a new Cortex cluster preempt every production ingester in a cascade, taking Grafana Cloud Hosted Prometheus down

Software defect2 cases

  1. IL-0150 A latent race condition in DynamoDB's DNS automation left an empty DNS record for dynamodb.us-east-1.amazonaws.com, and the DynamoDB and EC2 launch failures that followed caused EKS, ECS and Fargate container launch failures and cluster scaling delays in us-east-1
  2. IL-0024 Expensive cache-backed API calls and uncancelled database requests overloaded MongoDB and took the Hugging Face Hub down three times