  1. Symptoms

    On 5 October 2023 in us-central1, newly created VMs waited a long time before their networking worked, and VMs that had been live migrated lost connectivity for a long time after the migration. Networking telemetry showed cross-region packet loss to and from us-central1 from 03:08 US/Pacific. Health check state of VMs reached load balancers late.

    Trigger

    A management plane behaviour change, meant to decouple the processing of API updates to Instance Groups and Network Endpoint Groups used as load balancer backends, was deployed in us-central1 after rolling out to several other regions without incident.

    Root cause
    Component
    Contributing factor
    Detection

    Engineers were alerted to slowness in the virtual network control plane in us-central1 at 21:45 US/Pacific on 4 October, before the packet loss started, and to controller failures from memory exhaustion at 02:11 on 5 October. Networking telemetry showed cross-region packet loss from 03:08.

    Remediation
    • Increased the memory allocated to the virtual network router controllers
    • Rolled back the management plane change in us-central1
    • Restarted by hand the routers that were still not accepting updates
    Action items
    • Alert proactively on memory risks and unexpected memory increases
    • Refactor the deployment configuration so engineers can reallocate memory much faster
    • Re-evaluate existing practices and add safety mechanisms for API reconciliation
    • Make management plane changes more visible across teams so the changes can be correlated faster
    • Adjust the deployment footprint so a regional API change is less likely to exhaust memory across the region at once
    • Optimise memory use in the traffic routers and their controllers
  2. Symptoms

    From 09:55 UTC on 9 August 2023, DigitalOcean's AMS3, LON1 and SFO2 datacenters lost Internet access in waves of 10 to 15 minutes, about an hour apart. Users saw connectivity issues, latency and timeout errors on Droplets and on Droplet-based services such as Load Balancers, Kubernetes and Database clusters.

    Trigger

    The edge routers received an RPKI-related routing update, and the operating system software on them crashed its routing process on that update.

    Root cause
    Component
    Contributing factor
    Remediation
    • Rolled out a software update to the edge routers running the affected version, site by site
    • Rebalanced traffic on the congested routes between AMS3 and FRA1
    • Rolled out the fix to the redundant networking equipment so a failover would not hit the bug
    Action items
    • Upgrade all global edge routers to remove the bug
    • Bring the network upgrades already done in Asia to Europe and North America
  3. Symptoms

    On 7 July 2023 from 11:05 to 15:25 UTC many public Jenkins infrastructure services were completely down, including get.jenkins.io, plugins.jenkins.io, accounts.jenkins.io, javadoc.jenkins.io and incrementals.jenkins.io, while ci.jenkins.io, issues.jenkins.io, repo.jenkins-ci.org and www.jenkins.io were partly or completely disrupted.

    Trigger

    After the upgrade to Kubernetes 1.25 changed the range of the pods' originating IP and LDAP access was blocked, a fix (Azure PR 431) deployed at 10:55 UTC to set a proper set of pod IP ranges removed all node pools of the cluster.

    Root cause
    Component
    Contributing factor
    Detection

    After the upgrade, at 10:30 UTC, the team noticed that services inside the cluster, such as accounts.jenkins.io, could not reach the LDAP service.

    Remediation
    • Created the cluster again from scratch with a fixed network setup
    • Set a custom pod CIDR in a range separate from the virtual network
    • Moved the services and their DNS records to new public IPs
    • Pushed a pull request that recorded the manual rebuild, including the IP setup, in code
    Action items
    • Protect the public IPs from deletion with a Management Lock
    • Keep the public IPs in a separate resource group and point the Kubernetes-managed load balancers to it with the service.beta.kubernetes.io/azure-load-balancer-resource-group annotation
    • Improve network diagrams and documentation so possible overlaps are visible when preparing operations
    • Avoid changing the configuration of all AKS node pools at once
    Lessons

    The team said that changing one node pool at a time would have shown the problem after the first pool and avoided a full outage, and that the public IPs should change as little as possible because users behind corporate firewalls with allow-lists depend on them. The team also noted that it could rebuild, in under 4 hours, the cluster that hosts almost all public services.

  4. Symptoms

    From about 03:00 UTC on 30 June 2023, Fastmail and a fraction of the internet could not communicate with each other, and Fastmail first heard of it from customers through support tickets and social media. The problem lasted about 19 hours and affected an estimated 3-5% of customers as well as some email servers.

    Root cause
    Component
    Contributing factor
    Detection

    Customers told Fastmail through support tickets and social media. Fastmail's own monitors in multiple locations and its staff were not on affected networks and saw nothing.

    Action items
    • Select a provider for a second transit connection directly into Fastmail's servers, via Megaport or a provider present in 365's New Jersey datacenter, so that Fastmail controls the outbound path and can route around a network with problems
    Lessons

    With a single path for outbound traffic, Fastmail could not route around a provider's network problem and could not fix it itself. Being able to choose between several outbound paths would let Fastmail get everyone back online faster.

  5. Symptoms

    At 01:40 UTC on 14 February 2023, Twingate saw the number of connections drop in two of its Relay clusters, the one in us-east4 (Ashburn, Virginia) and the one in europe-west6 (Zurich, Switzerland).

    Trigger

    At 01:00 UTC on 14 February, Twingate started a Terraform change to all of its Relay clusters worldwide to add spot instance scaling; the rollout took about 45 minutes.

    Root cause
    Component
    Contributing factor
    Detection

    At 01:40 UTC Twingate noticed a decrease in the number of connections in the two clusters and started investigating.

    Remediation
    • Disabled the pods in the two affected Relay clusters at 02:04 UTC so Clients and Connectors reconnected to the next closest Relay cluster
    • Corrected the Terraform configuration error and redeployed the affected clusters at 03:30 UTC
    Action items
    • Make the staging environment reflect the sizing and configuration differences between Relay clusters
    • Create Terraform plans automatically for every environment and configuration variation on feature development branches
    • Extend Relay health checks so a cluster is not discoverable to Connectors and Clients when its network firewall tag is missing
    • Research and introduce staggered Terraform rollouts for the Relay cluster infrastructure
    • Add multi-cluster connectivity to Connectors so they handle regional Relay cluster problems automatically
Check your cluster for this

These 39 cases involve BGP routing and Network control plane (SDN). kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause10

Faulty deployment3 cases

  1. IL-0354 Fly.io private networking (6PN) broke for some machines after edges received gateway /80 routes
    Fly.io2026
  2. IL-0563 Linode servers lost connectivity in all data centers as route servers built incomplete BGP route tables
    Linode2025
  3. IL-0530 Virtual router controllers in us-central1 ran out of memory in a loop, cutting networking for new and migrated VMs

Cloud provider outage4 cases

  1. IL-0463 Secure Connect connectors timed out after a GKE control plane upgrade left Harness's internal load balancer unreachable
  2. IL-0368 PlanetScale's control plane went down and some database branches failed queries during the AWS us-east-1 outage
  3. IL-0261 Discord went fully offline twice as short network losses on Google Cloud sessions nodes wedged Erlang distribution
  4. IL-0494 Netlify's central load balancer IP stopped responding when Rackspace null-routed it in a DDoS, and A-record sites hung

Configuration change8 cases

  1. IL-0400 Public sector sites across Wales lost connectivity for over 8 hours as a PE router wrongly advertised a default route
    PSBA2026
  2. IL-0473 Jenkins infrastructure went fully down after a pod IP range fix deleted every AKS node pool and could not recreate them
  3. IL-0541 Two Twingate Relay clusters were discoverable but unreachable, so Clients and Connectors could not attach to them
  4. IL-0225 An IGP purge command made every Microsoft WAN router recompute routes, causing global latency, timeouts and packet loss
  5. IL-0266 Eqiad routers looped traffic between each other after a BGP MED change and could not reach other sites' public IPs
  6. IL-0539 KT's internet service failed nationwide for about 89 minutes as wrong routes spread from one router in Busan
    KT2021
  7. IL-0228 IPv4 routing across OVHcloud's global network broke after a router change put the full internet routing table into OSPF
  8. IL-0519 Apps on the cloud.gov PaaS became unavailable after an AWS security group change blocked their outbound traffic

Capacity exhaustion2 cases

  1. IL-0350 Hosts in an IONOS TXL cluster lost connectivity when an InfiniBand fabric resweep failed on a full multicast table
  2. IL-0472 Node-to-pod traffic and DNS failed on Tinder's 605-node Flannel cluster when every node's ARP cache passed gc_thresh3
    Tinder2019

Operator error6 cases

  1. IL-0349 IONOS Private Cloud in Berlin lost management access, storage and VM internet routing after a VLAN change
  2. IL-0244 A queued pull request destroyed the EKS subnet route table associations and Cloud Platform services went offline
  3. IL-0221 A backbone maintenance command disconnected all Facebook data centers, and its DNS servers withdrew their BGP routes
    Meta2021
  4. IL-0245 Acquia Cloud Enterprise sites in US-East went down when their web servers could no longer reach the Memcache servers
    Acquia2019
  5. IL-0431 During Mackerel's move to AWS, PostgreSQL failed over to a replica that had stopped replicating, losing an hour of data
    Hatena2017
  6. IL-0337 EBS volumes in one US East Availability Zone got stuck after a network change cut EBS nodes off from their replicas

Breaking change in an upgrade1 case

Organisation
  1. IL-0227 Most Heroku dynos in Private Spaces lost outbound connectivity after an automated OS update restarted host networking
    Heroku2025

Software defect7 cases

  1. IL-0233 A VPC control plane release broke IP alias routes in Nebius eu-west1, and Managed Kubernetes pods lost connectivity
    Nebius2025
  2. IL-0347 About 25% of Scaleway FR-PAR-1 hypervisors lost VPC connectivity when both VPC BGP route reflectors got stuck
  3. IL-0529 New Google Cloud VMs and other instances came up without network connectivity in all zones after VPC controllers stopped
  4. IL-0342 DigitalOcean's AMS3, LON1 and SFO2 data centers lost Internet connectivity in repeated waves as edge routers failed
  5. IL-0344 Linode's US-West data centers in Fremont and Santa Clara lost connectivity as the fibre circuits between them failed
    Linode2023
  6. IL-0222 Google Cloud US regions had heavy packet loss and some went unreachable after the network control plane was descheduled
  7. IL-0396 New or live-migrated GCE instances, VPN tunnels and network load balancers were unreachable on public IPs for over 2h

Dependency failure6 cases

  1. IL-0526 OpenStreetMap.org went offline, then read-only, for 56 hours after HE.net routing equipment cut both fibre uplinks
  2. IL-0509 SourceHut was down for 170 hours after a DDoS led its upstream network to null-route the PHL datacenter's subnet
  3. IL-0259 Outbound packets from Fastmail did not reach part of the internet for about 19 hours, cutting off 3-5% of customers
  4. IL-0267 Wikimedia's eqsin cache site went unreachable when both of its transport links to the core data centers were down
  5. IL-0358 Packet Public Cloud locations had high latency and unreachable paths from routing loops and blackholed traffic
    Packet2019
  6. IL-0258 FastMail was unreachable for almost two hours when the GRE tunnels carrying its traffic from Level 3 went down

DNS or network fault1 case

Contributing factor
–
Organisation
  1. IL-0423 A core switch failure in Paperspace's NY2 region cut VMs off their network file system and left them read-only

Hardware failure1 case

  1. IL-0525 OpenStreetMap.org went offline for 7h 27m when its uplink switch lost power during a data-centre power feed maintenance